Installation & Service InstructionsPOTTERTON envoy 30, 40, 50, 60, & 80 FAN POWERED BALANCED FLUEGAS fired CONDENSING BOILERTHE GAS SAFETY ( Installation AND USE) REGULATIONS In your own interest, and that of safety, it is law that all gas appliances are installed by competent persons,in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution. The polythene bags used for packaging are a potential hazard to babies and young childrenand MUST BE DISPOSED OF THESE Instructions WITH THE USER FOR USE ON FUTURE CALLSFor Use With Natural Gas(G20) Only At 2 Ombar ForUse in GB & IEIMPORTANTPLEASE READ THIS BOOKBEFORE INSTALLINGOPERATING OR SERVICINGTHIS & Replacement of Parts POTTERTON envoy is a high efficiency lightweight,automatically controlled wall hung gas fired condensingboiler. The flue system is room sealed and fanpowered. There are five models available with outputsof (30,000 Btu/hr), (40,000 Btu/hr), (50,000 Btu/hr), (60,000 Btu/hr) (80,000 Btu/hr).

Installation & Service Instructions POTTERTON ENVOY 30, 40, 50, 60, & 80 FAN POWERED BALANCED FLUE GAS FIRED CONDENSING BOILER THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS

Tags:

  Fired, Boiler, Gas fired, Potterton, Envoy, Potterton envoy

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Installation & Service Instructions POTTERTON …

1 Installation & Service InstructionsPOTTERTON envoy 30, 40, 50, 60, & 80 FAN POWERED BALANCED FLUEGAS fired CONDENSING BOILERTHE GAS SAFETY ( Installation AND USE) REGULATIONS In your own interest, and that of safety, it is law that all gas appliances are installed by competent persons,in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution. The polythene bags used for packaging are a potential hazard to babies and young childrenand MUST BE DISPOSED OF THESE Instructions WITH THE USER FOR USE ON FUTURE CALLSFor Use With Natural Gas(G20) Only At 2 Ombar ForUse in GB & IEIMPORTANTPLEASE READ THIS BOOKBEFORE INSTALLINGOPERATING OR SERVICINGTHIS & Replacement of Parts POTTERTON envoy is a high efficiency lightweight,automatically controlled wall hung gas fired condensingboiler. The flue system is room sealed and fanpowered. There are five models available with outputsof (30,000 Btu/hr), (40,000 Btu/hr), (50,000 Btu/hr), (60,000 Btu/hr) (80,000 Btu/hr).

2 The boilers which are designed to provide domestic hotwater and/or central heating must be used onINDIRECT FULLY PUMPED systems only, which maybe sealed or open boilers can be supplied with either of the followingflue systems:-One metre, metre, 2 metre, metre or 3 metrehorizontal and one metre, metre, 2 metre, metreor 3 metre following POTTERTON Myson controls arerecommended for use with your boiler :-Electronic Programmer EP2002, EP3002 or EP6002 Cylinder Thermostat PTT2 or PTT1 00 Room Thermostat PRT2 or PRT100 Frost Thermostat PRT100 FRMotorised Zone Valve M5V222 or M5V228 Motorised Diverter Valve M5V322 Thermostatic Radiator ValveData sheets describing these products are available EXTRAT erminal Wall Plate - where necessary can be fitted to theoutside wall face to improve the appearance, after makinggood around the terminal. Part No. 236349. Terminal guardPart No. roof flashing kit for use with vertical No.

3 Roof flashing kit for use with vertical No. DATA Page 3 boiler Output3040506080 Heat , , , ,600 NONE CONDENSINGHeat , , , , ,000 CONDENSINGHeat , , , , ,400 Gas RateM3/hft3 Size DetectorGas Control ValveElectrical SupplyFuse Rating - ExternalPacked WeightWater CapacityGas Supply ConnectionsFlow ConnectionsReturn ConnectionsCondense Discharge ConnectionMaximum Flow TemperatureMaximum Static HeadMinimum Static HeadFlue Size12H. C1. C3. 1P20 Furigas Pre-mixNorton 401S Hot SurfaceMorgan MatrocSIT Nova Mix 1-8 Air Gas Ratio230V - BSP Female Gas Cock22mm Compression22mm (3/4 ) Plastic Compression82 Degree (100 Ft) Measured from the top of the casing150mm (6 ) Measured from the top of the casing100mm boiler DIMENSIONS4 TECHNICAL DATA PAGE GENERAL ARRANGEMENT5 Installation REQUIREMENTS Page 5 GENERAL INFORMATIONBoth the user and the manufacturer rely heavily on theinstaller, whose job it is to install the boiler and connectit to a correctly designed heating system.

4 Acquaintyourself with the British Standards concerninginstallation requirements. If you need advice on anypoints, POTTERTON Service Operations will be pleased tohelp (see back page).CODES OF RegulationsModel Water Bye LawsBuilding Regulations/Building Standards for and Safety Document (The Electricityat Work Regulations 1989). of low pressure of gas boilers of rated inputnot exceeding circulation hot water CHsystems. Including smallbore andmicrobore domestic central of gas hot water suppliesfor domestic :1 Flues (for gas appliances of rated inputnot exceeding 60kW). :2 Air supply (for gas appliances of ratedinput not exceeding 60kw). for gas Installation in timberframed : Samples of envoy boiler have been examined bythe Netherlands Notified Body, Gastec and the range iscertified to comply with the essential requirements ofthe GAD and is permitted to carry the CE is important that no external control devices fluedampers, economisers etc, be directly connected to thisappliance unless covered by these Installation andService Instructions or otherwise recommended byPotterton in writing.

5 If in doubt please direct connection of a control device notrecommended by POTTERTON could invalidate thecertificate and the normal appliance warranty and couldalso infringe the Gas Safety Instructions must not be taken in any way asover-riding statutory SUPPLYA 230 volts - 50Hz, single phase electricity supply fused to 3amperes, must be provided in accordance with the latestedition of the lEE Wiring Regulations and any other localregulations that apply. The current rating of the wiring to theboiler must exceed 3 amperes and have a cross sectionalarea of at least in accordance with , supply to the boiler and its associated equipmentshould be controlled by an exclusive 3A fused double poleswitch (having at least 3mm contact separation in bothpoles) so that complete isolation from the supply can beachieved to enable servicing work to be carried out SUPPLYA gas supply pressure of 20 mbar is required at the inlet tothe appliance.

6 Performance data is based on use ofreference gas DRAINThe condensate outlet on the boiler is designed to (314 in) plastic overflow pipe, which if possibleshould discharge into the household drainage system andhave an internal termination. If this is not practical,discharge into an outside gully or soak away is avoid blockage of this pipe due to freezing it should berouted internally where possible and have sufficient fall overits entire length to dispose of condensate quickly. SeeBritish Gas Guidance Notes for the Installation of DomesticGas Condensing Boilers .LOCATION OF BOILERT hese boilers are not suitable for external Installation andshould not be fitted directly above a cooking appliance. Theboiler may be installed in any room, although particularattention is drawn to the requirements of the current lEEWiring Regulations and in Scotland, the electrical provisionsof the Building Standards applicable in Scotland withrespect to the Installation of the appliance in a roomcontaining a bath or REQUIREMENTS Page 6 Where a room-sealed appliance is installed in a roomTABLE 1containing a bath or shower, any electrical switch orAIR VENT AREAS appliance control, utilising mains electricity should bein2cm2so situated that it cannot be touched by a person3016103using the bath or the Installation of the boiler will be in an6032206unusual location.

7 Special procedures may be8043277necessary and gives detailed guidanceon this should be noted that due to the high efficiency of thisboiler a white plume of condensate will be emitted fromthe flue terminal therefore care should be taken whenselecting the terminal that the gas supply pipe and meter are largeenough for the appliance and any others that may berun off the same meter. Reference should be made MOUNTING SURFACEThe boiler must be mounted on a flat wall, which maybe of combustible material and must be sufficientlyrobust to take the weight of the boiler . The requirementsof the local authorities and the Building Regulationsmust be adhered NOTICE: TIMBER FRAMED HOUSESIf the appliance is to be fitted in a timber framedbuilding, it should be fitted in accordance with BritishGas Publication Operational Procedures for CustomerService Part 19. If in any doubt, advice should besought from the local region of British AROUND THE BOILERThe following minimum clearances must be maintainedafter Installation , for correct operation and servicing ofthe boiler :610mm (2ft)at the front of the boiler5mm ( in)each side of the boiler140mm ( in)at the top (measured from the topof the boiler case)100mm (4 in)at the bottom of the boilerVENTILATIONIf the boiler is to be installed in a confined space suchas a cupboard, the space will need must be provided at the top and bottom of thecupboard each of which should have a free area asshown in TABLE 1.

8 Further details for Installation of aboiler within a compartment are given in the openings draw air from outside the building the freeareas may be halved. Refer to Part 2 for TERMINAL AND DUCTING (Fig. 3a, b & c)The standard horizontal flue system ( POTTERTON Part ) is suitable for installations up to 1030mm,measured from the centre line of the boiler outlet to theoutside face of the metre flue extension kits (Part No. 430085)are available to extend horizontal flues to a maximumlength of 2920mm. The siting positions for horizontal flueterminals are shown in Figs. 3a, b & concentric vertical flue system is available (Part ) which when used in conjunction with one metreflue extension kits (Part No. 430085) is suitable for flueheights up to 3 metres to terminate through a siting of the flue terminal through a roof is shown inFig. the above flue systems should be used with with all condensing boilers, the flue will produce aplume of visible condensation for much of the time thatthe boiler is must therefore be taken in the siting of the terminalso as not to be a nuisance to adjacent particular, prolonged wetting of a facing wall should beavoided, if necessary by use of an appropriate a horizontal flue is sited less than 2m above a balcony,above ground, or above a flat roof to which people haveaccess, a suitable terminal guard must be fitted.

9 Thisserves two purposes, to protect the terminal againstdamage or interference and to protect passers-by. Aterminal guard is available (Part No. 236591).7 Installation REQUIREMENTS Page 7 Note: Where a flue terminal is installed less than onemetre from a plastic, or painted gutter, or 500mm frompainted eaves, an aluminium shield one metre long,should be fitted to the underside of the gutter or paintedsurface. A suitable wall plate should be fitted to thepainted wall surface of a mobile : It is absolutely ESSENTIAL to ensure thatproducts of combustion discharging from the terminalcannot re-enter the building, or any other adjacentbuilding, through ventilators, windows, doors, natural airinfiltration, or forced ventilation/air conditioning. Ifproducts of combustion are found to be re-entering anybuilding, the appliance MUST be turned 3 FLUE TERMINAL POSITIONSMm. Distance mmADIRECTLY BELOW AN OPENABLE WINDOW, AIR VENT, OR ANYOTHER VENTILATION OPENING300 BBELOW GUTTER, DRAIN/SOIL PIPE75 CBELOW EAVES (HORIZONTAL FLUE ONLY)200*BELOW A BALCONY/CARPORT ROOFNOT RECOMMENDEDEFROM VERTICAL DRAIN PIPES AND SOIL PIPES75 FFROM INTERNAL OR EXTERNAL CORNERS300 GABOVE ADJACENT GROUND OR BALCONY LEVEL300 HFROM A SURFACE FACING THE TERMINAL600 IFACING TERMINALS1200*FROM OPENING (DOOR/WINDOW) IN CARPORT INTO DWELLINGNOT RECOMMENDEDKVERTICALLY FROM A TERMINAL ON THE SAME WALL1,500 LHORIZONALLY FROM A TERMINAL ON THE SAME WALL300 MADJACENT TO OPENING300 NABOVE ROOF LEVEL (TO BASE OF TERMINAL)300 PFROM ADJACENT WALL TO FLUE300 QFROM INTERNAL CORNER TO FLUE400*BELOW EAVES OR BALCONY (VERTICAL FLUE)

10 NOT RECOMMENDEDSFROM FACING TERMINAL20008 THE SYSTEM Page 8 The envoy boiler has an aluminium alloy heatexchanger therefore all systems need to be thoroughlycleansed and the correct treatment added to the only system additives recommended by Pottertonare FERNOX-COPAL or GRACE DEARBORN-SENTINEL X 100 and should be used in accordancewith the manufacturers Instructions . This will includeuse of the appropriate system boiler must be used on INDIRECT FULLYPUMPED systems only, which may be sealed or system should be designed so that the maximumstatic head does not exceed (100ft) and aminimum of 150mm (6in). See FIG. all systems the pump live should be wired to theboiler terminal block, it will then be controlled by thepump over-run timer. This will ensure that the pump willcontinue to run after boiler shut down if the watertemperature is high, thus preventing nuisance operationof the overheat is important that where electrically operated zonevalves are used the boiler is wired so it does not cyclewhen the zone valves are closed.