Example: tourism industry

INSTALLATION INSTRUCTIONS AND OWNER'S …

INSTALLATION INSTRUCTIONS . AND OWNER'S manual . Vent-Free Gas Fireplaces UNVENTED GAS. FIREPLACE MODELS. HYDRAULIC MODELS. VFP(32,36)BP2(0,1)L(N,P)-1. MILLIVOLT MODELS. VFP(32,36)BP3(0,1)L(N,P)-1. INTERMITTENT PILOT MODELS. VFP(32,36)BP7(0,1)L(N,P)-1. Installer: Leave this manual with the appliance This appliance may be installed in an aftermar- Consumer: Retain this manual for future reference. ket, permanently located, manufactured (mobile). home, where not prohibited by local codes. WARNING: If the information in these instruc- This appliance is only for use with the type of gas tions are not followed exactly, a fire or explo- indicated on the rating plate. This appliance is not sion may result causing property damage, convertible for use with other gases.

installation instructions and owner's manual unvented gas fireplace models hydraulic models vfp(32,36)bp2(0,1)l(n,p)-1 millivolt models vfp(32,36)bp3(0,1)l(n,p)-1

Tags:

  Manual, Installation, Owner, Instructions, Installation instructions and owner s, Installation instructions and owner s manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of INSTALLATION INSTRUCTIONS AND OWNER'S …

1 INSTALLATION INSTRUCTIONS . AND OWNER'S manual . Vent-Free Gas Fireplaces UNVENTED GAS. FIREPLACE MODELS. HYDRAULIC MODELS. VFP(32,36)BP2(0,1)L(N,P)-1. MILLIVOLT MODELS. VFP(32,36)BP3(0,1)L(N,P)-1. INTERMITTENT PILOT MODELS. VFP(32,36)BP7(0,1)L(N,P)-1. Installer: Leave this manual with the appliance This appliance may be installed in an aftermar- Consumer: Retain this manual for future reference. ket, permanently located, manufactured (mobile). home, where not prohibited by local codes. WARNING: If the information in these instruc- This appliance is only for use with the type of gas tions are not followed exactly, a fire or explo- indicated on the rating plate. This appliance is not sion may result causing property damage, convertible for use with other gases.

2 Personal injury or loss of life. This is an unvented gas-fired heater. It uses air Do not store or use gasoline or other flam- (oxygen) from the room in which it is installed. mable vapors and liquids in the vicinity of Provisions for adequate combustion and ventila- this or any other appliance. tion air must be provided. Refer to page 8. WHAT TO DO IF YOU SMELL GAS. Do not try to light any appliance. WARNING: If not installed, operated and main- Do not touch any electrical switch; do not tained in accordance with the manufacturer's use any phone in your building. INSTRUCTIONS , this product could expose you to Immediately call your gas supplier from substances in fuel or from fuel combustion which a neighbor's phone.

3 Follow the gas sup- can cause death or serious illness. plier's INSTRUCTIONS . If you cannot reach your gas supplier, WATER VAPOR: A BY-PRODUCT OF UNVENTED. call the fire department. ROOM HEATERS. Water vapor is a by-product of gas combustion. INSTALLATION and service must be performed An unvented room heater produces approximately by a qualified installer, service agency or the one (1) ounce (30ml) of water for every 1,000 BTU's gas supplier. (.3KW's) of gas input per hour. Refer to page 8. Page 1. TABLE OF CONTENTS. SECTION PAGE. 3. IMPORTANT SAFETY 4. SAFETY INFORMATION FOR USERS OF 5. 6. 7. WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM 8. PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION GAS 11.

4 COMBUSTIBLE 12. FIREPLACE 13. INSTALLING HOOD AND TRIM 14. PLANNING 14. FIREPLACE FRAMING AND 15. PLACEMENT OF GLOWING EMBERS AND LAVA 16. VFP(32,36)BP(30,31) LIGHTING 17. VFP(32,36)BP(20,21) LIGHTING 18. VFP(32,36)BP(70,71) LIGHTING 19. OPERATION INSTRUCTIONS /FLAME 20. PILOT FLAME MILLIVOLT 23. MILLIVOLT AND HYDRAULIC 23. MILLIVOLT AND HYDRAULIC 24. INTERMITTENT CONTROL SYSTEM OPERATING 25. INTERMITTENT CONTROL SYSTEM WIRING 26. INTERMITTENT CONTROL SYSTEM OPTIONAL VARIABLE SPEED BLOWER INSTALLATION JUNCTION BOX WIRING INSTALLATION 32. OPTIONAL BRICK LINER INSTALLATION 32. MASTER PARTS DISTRIBUTOR 33. HOW TO ORDER REPAIR 33. VFP32BP(2,3,7) PARTS VFP36BP(2,3,7) PARTS PARTS 38.

5 39. Page 2 29898-11-1216. WARRANTY. Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the periods speci- fied below. Hearth products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the INSTRUCTIONS in the OWNER'S manual . This warranty applies to the original purchaser only and is not transferable. All warranty repairs must be accomplished by a qualified gas appliance technician. Limited Lifetime Parts Warranty with a Five-Year Limited Labor Warranty Combustion Chamber and Heat Exchanger If the combustion chamber or heat exchanger (see parts list) fails because of defective workmanship or material, Empire will repair or replace at Empire's option.

6 Within five years from the date of purchase, Empire will pay reasonable labor to have the defective part repaired or replaced at Empire's option. Limited Five-Year Parts & Labor Warranty All Other Components (Except Remote Controls, Thermostats, Accessories and Replacement Parts). Should any part fail because of defective workmanship or material within five years from the date of purchase, Empire will repair or replace at Empire's option. Within five years from the date of purchase, Empire will pay reasonable labor to have that defect repaired at Empire's option. Limited One-Year Parts Warranty Remote Controls, Thermostats, Accessories, and Parts Should any remote control, thermostat, accessory, or other part fail because of defective workmanship within one year from the date of purchase, Empire will repair or replace at Empire's option.

7 Duties Of The owner The appliance must be installed by a qualified installer and operated in accordance with the INSTRUCTIONS furnished with the ap- pliance. A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty period. Ready access to the appliance for service. What Is Not Covered Damages that might result from the use, misuse, or improper INSTALLATION of this appliance. Travel, diagnostic costs and freight charges on warranted parts to and from the factory. Claims that do not involve defective workmanship or materials. Unauthorized service or parts replacements. Removal and reinstallation cost. Inoperable due to improper or lack of maintenance.

8 How To Get Service To make a claim under this warranty, please have your receipt available and contact your installing dealer. Provide the dealer with the model number, serial number, type of gas, and purchase verification. The installing dealer is responsible for providing service and will contact the factory to initiate any warranted parts replacements. Empire will make replacement parts available at the factory. Shipping expenses are not covered. If, after contacting your Empire dealer, service received has not been satisfactory, contact: Consumer Relations Department, Empire Comfort Systems Inc., PO Box 529, Belleville, Illinois 62222, or send an e-mail to with Consumer Rela- tions in the subject line.

9 Your Rights Under State Law This warranty gives your specific legal rights, and you may also have other rights, which vary from state to state. 29898-11-1216 Page 3. IMPORTANT SAFETY INFORMATION. DANGER: Indicates a hazardous situation which, if not avoided, will WARNING: DO NOT operate this appliance unless all result in death or serious injury. components including logs, burners, and controls are in good working condition. Never operate this appliance if any log or WARNING: Indicates a hazardous situation which, if not avoided, twig is broken, or out of their intended position. Refer to the could result in death or serious injury. Log set placement INSTRUCTIONS for correct log and twig positioning.

10 CAUTION: Indicates a hazardous situation which, if not avoided, Replacement components are available through your local could result in minor or moderate injury. dealer as indicated in the How to Order Repair Parts section of NOTICE: Addresses practices not related to personal injury. the appliance manual . An unvented room heater having an input rating of more than Keep appliance area clear and free from combustible materials, 6,000 Btu per hour shall not be installed in a bathroom gasoline and other flammable vapors and liquids. An unvented room heater having an input rating of more than 10,000 WARNING: Failure to keep the primary air opening(s) of the Btu per hour shall not be installed in a bedroom or bathroom.


Related search queries