INSTALLATION INSTRUCTIONS DIN160 Cable

INSTALLATION INSTRUCTIONSDIN160 CableThis guide describes how to connect and use the national instruments DIN160 Cable , which has a maximum voltage rating of 150 V, CAT I. Use this Cable to connect the NI PXI-2510 switch module to your DIN160 Cable is available in three configurations: SH160 DIN-3 XDB50F SH160 DIN-160 DIN SH160 DIN-BARE WIREC ontentsWhat You Need to Get Started .. 1 Getting Started with the DIN160 2 Connectors .. 5 Cable Configurations .. 5SH160 DIN-3 XDB50F Cable .. 5SH160 DIN-160 DIN Cable ..12SH160 DIN-BARE WIRE 24 Accessories.

©National Instruments Corporation 5 DIN160 Cable Installation Instructions Connectors The cable connects a 160-pin female DIN connector (DIN160 connector) to three 50-pin female D-SUB

Tags:

  Installation, Instructions, National, Instruments, Cable, National instruments, Installation instructions din160 cable, Din160, Din160 cable installation instructions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of INSTALLATION INSTRUCTIONS DIN160 Cable

1 INSTALLATION INSTRUCTIONSDIN160 CableThis guide describes how to connect and use the national instruments DIN160 Cable , which has a maximum voltage rating of 150 V, CAT I. Use this Cable to connect the NI PXI-2510 switch module to your DIN160 Cable is available in three configurations: SH160 DIN-3 XDB50F SH160 DIN-160 DIN SH160 DIN-BARE WIREC ontentsWhat You Need to Get Started .. 1 Getting Started with the DIN160 2 Connectors .. 5 Cable Configurations .. 5SH160 DIN-3 XDB50F Cable .. 5SH160 DIN-160 DIN Cable ..12SH160 DIN-BARE WIRE 24 Accessories.

2 25 What You Need to Get StartedTo use the Cable , you need the following items: DIN160 Cable (Optional) Three NI TBX-50 screw terminal blocks for use with the SH160 DIN-3 XDB50F NI PXI-2510 switch module and documentation DIN160 Cable INSTALLATION Started with the DIN160 CableComplete the following steps to connect the Cable to the NI PXI-2510 and your application. Refer to Figures 2 through 4 for illustrations of the Cable , and refer to Figures 5 and 6 for illustrations of the the DIN160 connector to the NI PXI-2510 connector on the switch module as shown in Figure 1.

3 Connecting the DIN160 Connector to the NI the thumbscrews on the Connector3NI PXI-2510 Connector213 national instruments Corporation3 DIN160 Cable INSTALLATION one of the following steps and refer to Tables 1 through 10 in the Cable Configurations section to determine how to connect signals to your application. Connect the D-SUB connectors on the Cable to your application. For screw terminal access, you can connect directly to NI TBX-50 terminal blocks. Connect the second DIN160 connector on the Cable to your application. Connect the unterminated wires to your 2.

4 SH160 DIN-3 XDB50F Cable1 DIN160 Connector2 Thumbscrews3 Cable Leg Labels450-Pin Female D-SUB Connectors23241 DIN160 Cable INSTALLATION 3. SH160 DIN-160 DIN CableFigure 4. SH160 DIN-BARE WIRE Cable1 DIN160 Connectors2 Thumbscrews1 DIN160 Connector2 Thumbscrews3 Cable Leg Labels425 Unterminated, Tinned, and Stripped Wires22112341 national instruments Corporation5 DIN160 Cable INSTALLATION InstructionsConnectorsThe Cable connects a 160-pin female DIN connector ( DIN160 connector) to three 50-pin female D-SUB connectors, a second DIN160 connector, or six bundles, legs J0 J5, of unterminated, tinned, and stripped wires.

5 The DIN160 connector provides connection to the NI PXI-2510. The 50-pin female D-SUB connectors, second DIN160 connector, and unterminated cables provide connection to your application. Figures 5 and 6 show the pinouts for the DIN160 connectors and the 50-pin female D-SUB 5. DIN160 Mating ConnectorFigure 6. 50-Pin Female D-SUB ConnectorCable ConfigurationsThe DIN160 Cable is available in three configurations: SH160 DIN-3 XDB50F SH160 DIN-160 DIN SH160 DIN-BARE WIREThe following sections describe each of the CableThe SH160 DIN-3 XDB50F Cable is recommended for connecting the NI PXI-2510 to your system.

6 One end of the Cable terminates with a DIN160 connector. The other end of the Cable terminates with three 50-pin female D-SUB A32 PIN A1 PIN E1 PIN E32 Pin 1 Pin 17 Pin 34 Pin 50 Pin 18 Pin 33 DIN160 Cable INSTALLATION the pinouts and the pin assignments listed in Tables 1 through 3 to determine how to connect signals to your application using the SH160 DIN-3 XDB50F Cable . Refer to the NI Switches Help for a complete listing of channel names and 1. Pin Assignment for SH160 DIN-3 XDB50F Connector P150-Pin D-SUB Connector P1D-SUB PinNI PXI-2510 ChannelInterface Connector Pin1CH0D312 DUT0D323CH1C314 DUT1C325CH2B316 DUT2B327CH3A318 DUT3A329CH4D2910 DUT4D3011CH5C2912 DUT5C3013CH6B2914 DUT6B3015CH7A2916 DUT7A3018CH8D2719 DUT8D2820CH9C2721 DUT9C2822CH10B2723 DUT10B2824CH11A2725 DUT11A2826CH12D2527 DUT12D2628CH13C25 national instruments Corporation7 DIN160 Cable INSTALLATION Instructions29 DUT13C2630CH14B2531 DUT14B2632CH15A2533 DUT15A2634CH16D2335 DUT16D2436CH17C2337 DUT17C2438CH18B2339

7 DUT18B2440CH19A2341 DUT19A2442A0E3243A1E3144A2E3045A3E2947B0 E2748B1E2649B2E2550B3E2417 USER_0*E2846 USER_1*E23* USER_n signals are not used by the NI 1. Pin Assignment for SH160 DIN-3 XDB50F Connector P1 (Continued)50-Pin D-SUB Connector P1D-SUB PinNI PXI-2510 ChannelInterface Connector PinDIN160 Cable INSTALLATION 2. Pin Assignment for SH160 DIN-3 XDB50F Connector P250-Pin D-SUB Connector P2D-SUB PinNI PXI-2510 ChannelInterface Connector Pin1CH20D212 DUT20D223CH21C214 DUT21C225CH22B216 DUT22B227CH23A218 DUT23A229CH24D1910 DUT24D2011CH25C1912 DUT25C2013CH26B1914 DUT26B2015CH27A1916 DUT27A2018CH28D1719 DUT28D1820CH29C1721 DUT29C1822CH30B1723 DUT30B1824CH31A1725 DUT31A1826CH32D1527 DUT32D1628CH33C1529 DUT33C1630CH34B1531 DUT34B16 national instruments Corporation9 DIN160 Cable INSTALLATION Instructions32CH35A1533 DUT35A1634CH36D1335 DUT36D1436CH37C1337

8 DUT37C1438CH38B1339 DUT38B1440CH39A1341 DUT39A1442CH40D1143 DUT40D1244CH41C1145 DUT41C1246CH42B1147 DUT42B1248CH43A1149 DUT43A1217 BUSAE1450 BUSBE12 Table 2. Pin Assignment for SH160 DIN-3 XDB50F Connector P2 (Continued)50-Pin D-SUB Connector P2D-SUB PinNI PXI-2510 ChannelInterface Connector PinDIN160 Cable INSTALLATION 3. Pin Assignment for SH160 DIN-3 XDB50F Connector P350-Pin D-SUB Connector P3D-SUB PinNI PXI-2510 ChannelInterface Connector Pin1CH44D92 DUT44D103CH45C94 DUT45C105CH46B96 DUT46B107CH47A98 DUT47A109CH48D710 DUT48D811CH49C712 DUT49C813CH50B714 DUT50B815CH51A716 DUT51A818CH52D519 DUT52D620CH53C521 DUT53C622CH54B523 DUT54B624CH55A525 DUT55A626CH56D327 DUT56D428CH57C329 DUT57C430CH58B331 DUT58B4 national instruments Corporation11 DIN160 Cable INSTALLATION Instructions32CH59A333 DUT59A434CH60D135 DUT60D236CH61C137 DUT61C238CH62B139 DUT62B240CH63A141

9 DUT63A242CH64E843 DUT64E944CH65E645 DUT65E746CH66E447 DUT66E548CH67E249 DUT67E317 USER_2*E1050 RESERVED E1* USER_n signals are not used by the NI PXI-2510. RESERVED signal is reserved by the NI PXI-2510 for future 3. Pin Assignment for SH160 DIN-3 XDB50F Connector P3 (Continued)50-Pin D-SUB Connector P3D-SUB PinNI PXI-2510 ChannelInterface Connector PinDIN160 Cable INSTALLATION CableThe SH160 DIN-160 DIN Cable is recommended for connecting the NI PXI-2510 to a system that terminates with a male DIN160 the pinouts and the pin assignments listed in Table 4 to determine how to connect signals to your application using the SH160 DIN-160 DIN Cable .

10 Refer to the NI Switches Help for a complete listing of channel names and 4. Pin Assignment for SH160 DIN-160 DIN Cable160 DIN Mating Connector160 DIN P1/P2 PinNI PXI-2510 ChannelD31CH0D32 DUT0C31CH1C32 DUT1B31CH2B32 DUT2A31CH3A32 DUT3D29CH4D30 DUT4C29CH5C30 DUT5B29CH6B30 DUT6A29CH7A30 DUT7D27CH8D28 DUT8C27CH9C28 DUT9B27CH10B28 DUT10A27CH11A28 DUT11 national instruments Corporation13 DIN160 Cable INSTALLATION InstructionsD25CH12D26 DUT12C25CH13C26 DUT13B25CH14B26 DUT14A25CH15A26 DUT15D23CH16D24 DUT16C23CH17C24 DUT17B23CH18B24 DUT18A23CH19A24 DUT19E32A0E31A1E30A2E29A3E27B0E26B1E25B2 E24B3E28 USER_0*E23 USER_1*D21CH20D22