Transcription of Inverter MICROMASTER 430 - paratrasnet
1 Siemens DA 2007/20083/13 InverterMICROMASTER 4303/2 Description3/4 Circuit diagrams3/6 Technical data3/9 Selection and ordering data3/10 Options3/19 Dimension drawings Siemens AG 20073/2 Siemens DA 2007/2008 MICROMASTER 4303nApplicationnMain characteristicsnOptions (overview)nInternational standardsThe MICROMASTER 430 in-verter is suitable for a variety of variable-speed drive appli-cations. Its flexibility provides for a wide spectrum of appli-cations. It is especially suit-able for use with industrial pumps and fans. The Inverter is especially characterized by its customer-oriented perfor-mance and ease-of-use. It has more inputs and outputs than the MICROMASTER 420, an optimized operator panel with manual/automatic switchover and adapted software MICROMASTER 430 in-verter has a modular operator panels and com-munication modules can be easily , guided start-upnModular construction al-lows maximum configura-tion flexibilitynSix programmable isolated digital inputs nTwo scaleable analog in-puts (0 V to 10 V, 0 mA to 20 mA) can also be used as a 7th/8th digital inputnTwo programmable analog outputs (0 mA to 20 mA)nThree programmable relay outputs (30 V DC/5 A resis-tive load.)
2 250 V AC/2A in-ductive load)nLow-noise motor operation thanks to high pulse fre-quencies, adjustable (ob-serve derating if necessary)nComplete protection for motor and inverternControl of up to three addi-tional drives on the basis of PID control (motor staging)nOperation of drive directly on mains (with external by-pass circuit)nLow-energy modenDetects dry run of pumps (belt failure detection).nLine commutating chokesnOutput chokesnLC filter and sinusoidal filternGland platesnBasic Operator Panel 2 (BOP-2) for parameterizing the inverternCommunication modules PROFIBUS DeviceNet CANopennPC connection kitsnMounting kits for installing the operator panels in the control cabinet doorsnPC start-up tools execut-able under Windows 98 and NT/2000/ME/XP integration with Drive ESnThe MICROMASTER 430 Inverter complies with the requirements of the EU low-voltage guidelinenThe MICROMASTER 430 Inverter has the > mark-ingnacc.
3 To u and cu certifiednc-tick l4 Note:See Appendix for Siemens AG 2007 Siemens DA 2007/20083/3 MICROMASTER 4303nMechanical featuresnPerformance featuresnProtection featuresnModular designnOperating temperature 10 C to +40 C(+14 F to +104 F)nCompact housing as a re-sult of high power densitynEasy cable connection, mains and motor connec-tions are separated for opti-mum electromagnetic com-patibilitynDetachable operator panelsnScrewless control terminal strip on detachable I/O IGBT technologynDigital microprocessor controlnFlux Current Control (FCC) for improved dynamic re-sponse and optimized mo-tor controlnLinear V/f characteristicnQuadratic V/f characteristicnMultipoint characteristic (programmable V/f charac-teristic)nFlying restartnSlip compensationnAutomatic restart following mains failure or faultnEnergy saving mode (stop-ping e. g. of a pump at low speeds)nMotor staging (connection and disconnection of addi-tional motors, use of invert-er as control drive in a pump cascade)nManual/automatic modenLoad torque monitoring (belt failure detection; detects dry run of pumps)nHigh-grade internal PID controller for simple pro-cess controlnProgrammable accelera-tion/deceleration times from 0 s to 650 snRamp smoothingnFast Current Limit (FCL) for trip-free operationnFast, repeatable digital in-put response timenFine adjustment using two high-resolution 10-bit ana-log inputsnCompound braking for con-trolled rapid brakingnFour skip frequenciesnRemovable Y capacitor for use on IT systems (with non-grounded mains sup-plies, the Y capacitor must be removed and an output choke installed).
4 NOverload kW to 90 kW:Overload current x rat-ed output current ( +140 % overload capabili-ty) for 3 s, and x rated output current ( 110 % overload capability) for 60 s, cycle time 300 s110 kW to 250 kW:Overload current x rat-ed output current ( 150 % overload capability) for 1 s, and x rated out-put current ( 110 % over-load capability) for 59 s, cycle time 300 snOvervoltage/undervoltage protectionnInverter overtemperature protectionnSpecial direct connection for PTC or KTY to protect the motornEarth fault protectionnShort-circuit protectionnI2t motor thermal protectionnLocked motor protectionnStall preventionnParameter interlockDescription Siemens AG 20073/4 Siemens DA 2007/2008 MICROMASTER 4303nGeneral circuit diagram=3~ADADPEPE U, V, WM1 2 ADC ADC1 2A/DA/D+ 10 V0 V NPNPNPDCNADCNSDCPSDCPAB+/DC+DC-~=ADC1+AD C2+ADC2-ADC1-DIN1 DIN2 DIN3 DIN4 DIN5 DIN6 PTCAPTCBDAC1+DAC2+DAC2-DAC1-P+N-COMCOMCO MNCNONONONC12341011567816179281415121326 27293020181925232422210 - 20 mAmax.
5 5000 - 20 mAmax. 500 0 - 20 mA0 - 10 V5678161728 DIN1 DIN2 DIN3 DIN4 DIN5 DIN6 24 V+_ADADRS485 PESI3 AC 380 - 480 V1 260 Hz 50 Hz ~=CPUL/L1, N/L2, L3L1, L2, L34,7 kororMotor30 V DC/5 A (resistive load)250 V AC/2 A (inductive load)Frame sizesC to FFrame sizesFX and GXmax. 100 mA(isolated)Output +24 Vmax. 100 mA(isolated)Output 0 VcurrentvoltageautomaticTerminals onlyfor measuringpurposesNotusedDIP switch(on control board)DIPswitch(on I/Oboard)Opto isolationG_DA51_EN _00012 COM linkBOP link24 V externalRelay 3 Relay 2 Relay 1 CBoptionPTC/KTY 84 Circuit diagrams Siemens AG 2007 Siemens DA 2007/20083/5 MICROMASTER 4303nTerminal connection diagram222425231820211927293028181726161 21415138101196751342RL1-ARL2-BRL1-BRL1-C RL2-CRL3-ARL3-BRL3-CDAC1+ DAC1- P+N-DIN5 DIN6 DAC2+ DAC2-PTCAPTCBPE0 V+10 V0 VADC1+ADC1-DIN1 DIN2 DIN3 DIN4 ADC2+ ADC2-+24 VS2S1(DIN7)(DIN8)AIN1 AIN2 NPN *)PNP *)DIP Switches.
6 0 mA to 20 mA or0 V to 10 VOutput relay contactsAnalog output 1 Digital inputsAnalog output 2RS-485(USS-protocol)Voltagesupply 10 VDigital inputsAnalog input 1 Analog input 2*) PNP or NPN possible G_DA51_EN_05107 View AExample, frame size CView AMains connectionsMotor connectionsCircuit diagrams Siemens AG 20073/6 Siemens DA 2007/2008 MICROMASTER 4303nMICROMASTER 430 inverterMains voltage and Power ranges3 AC 380 V to 480 V 10 % kW to 250 kW (variable torque)Power frequency47 Hz to 63 HzOutput frequency kW to 90 kW110 kW to 250 kW0 Hz to 650 Hz0 Hz to 267 HzPower factor kW to 90 kW110 kW to 250 kW96 % to 97 %97 % to 98 % (Further information is available on the Internet at: )Overload capability kW to 90 kW110 kW to 250 kWOverload current x rated output current ( +140 % overload capability) for 3 s, and x rated output current ( 110 % overload capability) for 60 s, cycle time 300 sOverload current x rated output current ( 150 % overload capability) for 1 s x rated output current ( 110 % overload capability) for 60 s, cycle time 300 s Inrush currentLess than rated input currentControl methodLinear V/f characteristic; quadratic V/f characteristic; multipoint characteristic (programmable V/f characteristic); flux current control (FCC), energy saving modePulse frequency kW to 90 kW110 kW to 250 kW4 kHz (standard)2 kHz to 16 kHz (in 2 kHz steps)2 kHz (standard)2 kHz to 4 kHz (in 2 kHz steps)Fixed frequencies15, programmableSkip frequency ranges4, programmableSetpoint Hz digital; Hz serial.
7 10 bit analogDigital inputs6 fully programmable isolated digital inputs; switchable PNP/NPNA nalog inputs2 programmable analog inputs 0 V to 10 V, 0 mA to 20 mA and 10 V to +10 V (AIN1) 0 V to 10 V and 0 mA to 20 mA (AIN2) both can be used as 7th/8th digital inputRelay outputs3, programmable, 30 V DC/5 A (resistive load); 250 V AC/2A (inductive load)Analog outputs2, programmable (0/4 mA to 20 mA)Serial interfacesRS-485, optional RS-232 Motor cable kW to 90 kWwithout output chokewith output choke110 kW to 250 kWwithout output chokewith output chokemax. 50 m (shielded); max. 100 m (unshielded)see variant dependent optionsmax. 200 m (shielded); max. 300 m (unshielded)see variant dependent optionsElectromagnetic kW to 90 kWFor inverters without kW to 15 kW to 90 kW110 kW to 250 kWInverter with internal filter Class A availableEMC filter, Class B to EN 55 011 available as an optionEMC filter, Class B from Schaffner available as an optionEMC filter, Class A available as an optionBrakingDC braking, compound brakingDegree of protectionIP20 Operating temperature kW to 90 kW110 kW to 250 kW 10 C to + 40 C (+14 F to +104 F)0 C to +40 C (+32 F to +104 F)Storage temperature 40 C to + 70 C ( 40 F to +158 F)Relative humidity95 % (non-condensing) Installation kW to 90 kW110 kW to 250 kWUp to 1000 m above sea level without deratingUp to 2000 m above sea level without deratingStandard SCCR (Short Circuit Current Rating) 1)FSC: 10 kAFSD, FSE, FSF, FSFX, FSGX.
8 42 kAProtection features forundervoltage, overvoltage, overload, earth faults, short-circuits, stall prevention, locked motor protection, motor overtemperature, Inverter overtemperature, parameter change protectionConformity with kW to 90 kW110 kW to 250 kWu, cu, >, c-tick l4u available soon, cu available soon, >> markingConformity with low-voltage directive 73/23/EECC ooling-air volumetric flow required, dimensions and weights (without options)Frame size (FS)CDE F without filterF with filterFXGXC ooling-air volumetric flow required (l/s)/(CFM) x x x x Wx D (mm)245 x 185 x 195520 x 275 x 245650 x 275 x 245850 x 350 x 3201150 x 350 x 3201400 x 326 x 3561533 x 326 x 545 Weight, approx. (kg) ) For footnote, see page 3 : Cubic Feet per MinuteTechnical data Siemens AG 2007 Siemens DA 2007/20083/7 MICROMASTER 4303nDerating dataPulse frequencyOperating temperatureOutput(for 3 AC 400 V)Rated output current in Afor a pulse frequency ofkW2 kHz4 kHz6 kHz8 kHz10 kHz12 kHz14 kHz16 600204080100%30020105040 C-1070 Rated output currentOperating temperatureG_DA51_EN_05045a406000204080D A51-5047a10010%55 C85203045 Rated output currentOperating temperatureAInverter kW to 90 kWInverter 110 kW to 250 kW1) Applies to industrial control cabinet installations to NEC article 409/UL 508A.
9 For further information, visit us on the Internet at: data Siemens AG 20073/8 Siemens DA 2007/2008 MICROMASTER 4303nDerating data (continued)Installation altitude above sea level200060040000204080DA51-50461001000% 3000 m85 Rated output currentOperational altitudeA200060040000204080DA51-5019b100 1000%3000 m77 Mains voltageOperational altitudeAPermissible output current in % of the rated output currentInverter kW to 90 kW200060040000204080DA51-5018c1001000%30 00 mRated output currentOperational altitudeA200060040000204080DA51-5019b100 1000%3000 m77 Mains voltageOperational altitudeAPermissible mains voltage in % of the max. possible mains voltageInverter kW to 90 kWInverter 110 kW to 250 kWInverter 110 kW to 250 kWTechnical data Siemens AG 2007 Siemens DA 2007/20083/9 MICROMASTER 4303nMICROMASTER 430 inverterOutputRated input currentRated output currentFrame sizeOrder (FS) MICROMASTER 430 without filter 4) MICROMASTER 430 with internal filter Class A 3)Mains operating voltage 3 AC 380 V to 480 V 1) 1) 1) 1) 1) 1) 1)75E 1)90E 1) 1) 1) 2)205FX6SE6430-2UD41-1FA0 2)250FX6SE6430-2UD41-3FA0 2)302GX6SE6430-2UD41-6GA0 2)370GX6SE6430-2UD42-0GA0 2)477GX6SE6430-2UD42-5GA0 See Appendix for note on MICROMASTER 430 invert-ers are supplied with a Status Display Panel (SDP).
10 A BOP-2 or other options have to be ordered separately (see Pages 3/14 to 3/16).nMotors for MICROMASTER 430 Catalog D contains se-lection and ordering data for motors which are particularly suitable for operation with the MICROMASTER 430 inverters (see Appendix for overview).This catalog is suitable for IEC motors. For motors according to US standards (NEMA) please refer to Catalog D (see Appendix for overview) and to: ) Supplementary conditions: Input current at rated operating point, applicable at short-cir-cuit voltage of the supply USC= 2 % with reference to the Inverter rated power and rated mains operating voltage of 400 V without a line commutat-ing ) Supplementary conditions: Input current at rated operating point, applicable at short-cir-cuit voltage of the supply USC$ % with reference to the Inverter rated power and rated mains voltage of 400 ) Use of MICROMASTER invert-ers with internal filter is not per-missible on non-grounded mains ) Acc.