Example: dental hygienist

ISO4401 Appendix - Eaton

AppendixISO4401 02/03/05/07/08 Eaton Industrial Valve Catalog E-VLVI-SS001-E October 2016Q-2 QFluid RecommendationsViscosity & Cleanliness RecommendationMinimumOptimumMaximumISO cSt20 43 cSt2158 cSt20/18/15(45 SUS)(100-200 SUS)(10000 SUS)IntroductionHydraulic fluids are one of the vital components of hydraulic system. Proper selection of oil assures satisfactory life and operation of system components. The purpose of this section is to provide readers with the knowledge required to select the appropriate fluids for use in systems that employ Eaton hydraulic componentsViscosity and TemperatureViscosity is the measure of a fluid s resistance to flow.

Q-4 EATON Industrial Valve Catalog -VVI-SS001- October 201 Q Subplates and Connection Plates for Four-Port Directional Valves ISO 4401, 02/03/05/07/08 General Description This range of subplates and auxiliary connection plates

Tags:

  Eaton, Appendix, 4410, Iso4401, Iso4401 appendix, Iso 4401

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of ISO4401 Appendix - Eaton

1 AppendixISO4401 02/03/05/07/08 Eaton Industrial Valve Catalog E-VLVI-SS001-E October 2016Q-2 QFluid RecommendationsViscosity & Cleanliness RecommendationMinimumOptimumMaximumISO cSt20 43 cSt2158 cSt20/18/15(45 SUS)(100-200 SUS)(10000 SUS)IntroductionHydraulic fluids are one of the vital components of hydraulic system. Proper selection of oil assures satisfactory life and operation of system components. The purpose of this section is to provide readers with the knowledge required to select the appropriate fluids for use in systems that employ Eaton hydraulic componentsViscosity and TemperatureViscosity is the measure of a fluid s resistance to flow.

2 The most important characteristics to consider when choosing a fluid to be used in a hydraulic system is viscosity. The fluid must be thin enough to flow easily but thick enough to maintain adequate lubricating film between components and to maintain proper sealing at the operating temperatures of the hydraulic system. For viscosity requirements, see of any fluid is relative to temperature, as the fluid warms the viscosity decreases and vice versa. When choosing a fluid, it is important to consider the start-up and operating temperatures of the hydraulic system. A high VI fluid shows relatively small change of viscosity with temperature.

3 Lubricants used for hydraulic applications may contain viscosity index improvers (VII). They refer to these fluids as viscosity index improved or multiviscosity fluids. The viscosity of these fluids may drop down in use due to shearing ofVI improvers used in the formulations. Anti-wear hydraulic oils containing polymeric thickeners, viscosity index improvers (VII) are generally used for wide band operating temperature applications These fluids experience temporary and permanent viscosity loss during use in hydraulic system. Check the extent of viscosity loss (shear stability) to avoid hydraulic service below the recommended minimum viscosity.

4 Oil with good shear stability is recommended for wide band temperature applications. Multi-grade engine oils, ATFs, UTTOs, etc., also contain VIIs, and viscosity loss will be encountered during of the fluid in a hydraulic system is extremely important. More than 70% of all failures are caused by contamination Eaton recommends that the fluid used in its hydraulic components be maintained per ISO 4406. Cleanliness level requirements vary with the hydraulic components. The cleanliness of a hydraulic system is dictated by the cleanliness requirements of the most stringent component in the system. Cleanliness requirements for specific products are given in the table.

5 OEM s and distributors who use Eaton hydraulic components in their hydraulic systems should provide these requirements in their designs. Contact Eaton filter representative for filtration MaintenanceThe condition of a fluid has a direct effect on the performance and reliability of the system. Maintaining proper fluid viscosity, cleanliness level, water content, and additive level is essential for excellent hydraulic system performance. Routine fluid condition monitoring is SelectionPremium grade anti-wear (AW) petroleum based hydraulic fluids will provide the best performance with Eaton hydraulic components.

6 Lubricants that pass Eaton Vickers 35VQ25A high pressure vane pump test ( Eaton ATS- 373 test procedure, ASTM specification D 6973) are considered good quality antiwear hydraulic fluids. Automotive crank case oils with American Petroleum Institute (API) letter designation SF, SG, SH, SJ, or higher per SAE J 183 classes of oils are recommended for applications using Eaton DG valves Automotive crankcase oils generally exhibit less shear stability compared to industrial anti-wear hydraulic fluids, which can result in higher loss of viscosity during service life. Other mineral oil based lubricants commonly used in hydraulic systems are automatic transmission fluids (ATF) and universal tractor transmission oils (UTTO).

7 Synthetic hydrocarbon base stocks, such as polyalphaolefins (PAO) are also used to formulate hydraulic fluids, engine oils, ATFs and UTTOs Alternate fluids are recommended when specific properties, such as fire resistance biodegradability etc., are necessary for the application. Keep in mind that alternative fluids may differ from AW petroleum fluids in NotesWhen choosing a hydraulic fluid, all the components in the system must be considered. Viscosity limitations has to meet the most stringent component requirements. For any system where the fluid is non-petroleum oil, set the target one ISO code cleaner for each particle size, than that of petroleum fluids.

8 Keep adequate fluid level in the reservoir. Take fluid level reading when the system is cold. For more details, refer to Eaton Fluid Recommendation Document # 03-401-2010. Contact your Eaton representative, if you have specific questions about the fluid requirements of Eaton hydraulic Industrial Valve Catalog E-VLVI-SS001-E October 2016Q-3 QTabulation of bolt kits and seal kitsDirection control single stage I Size 2 (D02)Bolt kit (metric)Seal kitSeal kit commentsDG4V-202-15649302-156492DG2V-2DG 17V-2DG21V-2II Size 3 (D03)Bolt kit (metric)Seal kitSeal kit commentsDG4V3-60616452858996 Seal kit for DG4V 360 din858996 Seal kit for DG4V 360 flying lead02-414945 Seal kit for F6-DG4V3(S)

9 -6002-398366 Seal kit - DG4V-3M-*-6002-398367 Seal kit - F6-DG4V-3M-*-60859049 Soft shift seal kit DG4V3-7002-397447F302-397448F6DG3/4VP-39 92686 Nitrile992758 Viton (F3)DG3V-302-110959DG17V-3696877 DG18V-3696925DG20V-3920324 III. Size 5 (D05)Bolt kit (metric)Seal kitSeal kit commentsDG4V5466310459057AC459058 DCDirection Control Two stage I. Size 5 (D05)Bolt kit (metric)Seal kitSeal kit commentsDG3V-5/DG5V-546631002-156844II. Size 7 (D07)Bolt kit ( metric)Seal kitSeal kit commentsDG3V-7/DG5V-7858918 III. Size 8 (D08)Bolt kit (metric)Seal kitSeal kit commentsDG3V-8/DG5V-825565502-329888 STANDARD10 Design02-329889F3IV.

10 Size 10 (D10)Bolt kit (metric)Seal kitSeal kit commentsDG3V-10/DG5V-1046158002-329888 STANDARD10 Design02-329889F3 Direction Control Stak Valves I. Size 2 (D02)Bolt kit (metric)Seal kitSeal kit commentsDGMC-2 Not available02-157032 DGMR-202-157033 DGMR1-202-157033 DGMX2-202-157033 DGMPC-202-157030 DGMDC-202-157030 DGMFG-202-157031 DGMFN-202-157031 DGMFD-202-157031II. Size 3 (D03)Bolt kit (metric)Seal kitSeal kit commentsDGMC-3 Not available870737 DGMR-3870739 DGMR1-3870739 DGMX-3870737 DGMDC-3870708 DGMPC-3870708 DGMFN-3870707 III. Size 5 (D05)Bolt kit (metric)Seal kitSeal kit commentsDGMC-5 Not available978463 DGMR-5978464 DGMR1-5978464 DGMX2-5978464 DGMDC-5978466 DGMPC-5978465 DGMFN-5639407 Eaton Industrial Valve Catalog E-VLVI-SS001-E October 2016Q-4 QSubplates and Connection Plates forFour-Port Directional Valves iso 4401 , 02/03/05/07/08 General DescriptionThis range of subplates and auxiliary connection plates offers an economical way of mounting the range of Vickers directional control valves and associated stackable auxiliary valves.