Example: marketing

Line Cord Plug Reference Certification of Calibration ...

Innovative Features and Rewarding BenefitsNALGENE and NUNC cryogenic storage give you everything you need to safelystore precious specimens, organize freezer space and simplify sample and NUNC combine to provide one-stop shopping for the widest varietyand highest quality of externally and internally threaded cryovials, storage boxes, labtop coolers and Mr. Frosty controlled rate freezing further information regarding these products - visit Scientific RevcoUltima IIEliteValueUltima II CryogenicOperating Temperature-86 C or -40 C-86 C or -40 C-86 C or -40 C-150 C or -140 CBenefitRefrigeration SystemLegaci refrigeration system Long life, dependability for ultra-low useOrbital refrigeration system Patented, single compressor systemdeveloped for cryogenic use1 HP industrial grade compressor(s) Refrigeration powerCFC-free refrigerants Environmentally friendly, high performanceDuPont Suva low-stage refrigerants Specially formulated for ultra-low applicationsDownfeed evaporator Smoother refrigerant flowWashable condenser filter Maintains peak condenser efficiencyControl TechnologyMicroprocessor-based or solid-stateIntrLogicMicroprocessorSolid- StateIntrLogicDigital accuracySetpoint security Locks in operating and alarm setpointsTemperature and high/low setpoints Adjustable in 1 C incrementsElectrical SystemAutomatic voltage boost Compensates for low voltageDigital power monitoring Displays actual incoming line voltageSurge suppressor o

18 Choose from two chest models, with operating temperatures of -140°C and -150°C. Model ULT-10140-9 shown with optional temperature recorder. *All dimensions …

Tags:

  Calibration, Reference, Line, Plugs, Certifications, Cord, Line cord plug reference certification of calibration

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Line Cord Plug Reference Certification of Calibration ...

1 Innovative Features and Rewarding BenefitsNALGENE and NUNC cryogenic storage give you everything you need to safelystore precious specimens, organize freezer space and simplify sample and NUNC combine to provide one-stop shopping for the widest varietyand highest quality of externally and internally threaded cryovials, storage boxes, labtop coolers and Mr. Frosty controlled rate freezing further information regarding these products - visit Scientific RevcoUltima IIEliteValueUltima II CryogenicOperating Temperature-86 C or -40 C-86 C or -40 C-86 C or -40 C-150 C or -140 CBenefitRefrigeration SystemLegaci refrigeration system Long life, dependability for ultra-low useOrbital refrigeration system Patented, single compressor systemdeveloped for cryogenic use1 HP industrial grade compressor(s) Refrigeration powerCFC-free refrigerants Environmentally friendly, high performanceDuPont Suva low-stage refrigerants Specially formulated for ultra-low applicationsDownfeed evaporator Smoother refrigerant flowWashable condenser filter Maintains peak condenser efficiencyControl TechnologyMicroprocessor-based or solid-stateIntrLogicMicroprocessorSolid- StateIntrLogicDigital accuracySetpoint security Locks in operating and alarm setpointsTemperature and high/low setpoints Adjustable in 1 C incrementsElectrical SystemAutomatic voltage boost Compensates for low voltageDigital power monitoring Displays actual incoming line voltageSurge suppressor optionaloptional Minimizes effect of voltage spikesAlarm (Automatic Incident Monitor)

2 Identifies temperature deviationsAudible/visual warning audible only AutomaticBattery backup AutomaticBattery capacity indicator Displays % battery power remainingTouchpad alarm test Simulates overtemperature conditionRS-232 data port optional Includes software for data export to PCRemote alarm contacts For connection to remote monitoring systemMonitoring SystemLifeguard compressor protection Monitors/adjusts compressor performanceExtreme ambient alert Warns if room temperature is too warmVoltage boost indicator Alerts to low power, boosts low voltageCheck fuse indicator Alerts to surge suppressor eventClean filter indicator Advises when to remove and clean filterCabinet Construction, GeneralFoamed-in-place urethane insulation Higher "R" value1" ( ) diameter access port Easy access through wallCoved corner interior Easy to clean, improved uniformityEnhanced acoustic insulation Reduces compressor soundHeavy duty swivel casters Cabinet mobility as requiredUpright CabinetsEye-level IntrLogic controller Easy to read, convenient accessCryoLatch n/aOne-handed operationLow-profile design n/aOnly " (1970mm) highPressure equalization port n/aFaster re-entry to freezerFour shelves and five inner doors n/aCreates five interior compartmentsChest CabinetsLow-profile design with stay-open lid Easier access to inventoryInsulated sub-lids Additional protection19 Electrical InformationThermo Scientific Revco freezers aredesigned to meet UL, CUL and CEcriteria for safety and performance.

3 Allconnections must comply with localelectrical codes. Selection charts for each standardmodel list voltage, rated amperage,recommended circuit breaker size and NEMA (National ElectricalManufacturers Association, USA)electrical plug information Freezers are supplied with line cordplugs (P) which require correspondingreceptacles illustrated on the line cordplug Reference chart (right) Site preparation requires availability of the proper receptacle; a dedicatedcircuit is recommended Some freezers require a hardwireconnection to a dedicated circuit. Thisconnection is the responsibility of thecustomer and must be made by aqualified electrician Special voltage selections may beavailable at extra cost and must bespecified when ordering For questions regarding sitepreparation, installation and electricalconnection, contact your salesrepresentativeCertification of CalibrationControl, alarm and temperaturerecording systems are systematicallycalibrated at the factory for accurateperformance.

4 An optional certificate ofcalibration to an NIST (National Instituteof Standards and Technology, formerlyNational Bureau of Standards) traceableinstrument includes a model numberand serial number certificate (singlepoint Calibration ). Multiple pointcalibration is also available. Calibrationcertificates must be requested Testing ProgramValidation testing services in advance of shipment can accelerate in-houseFDA Installation Qualification (IQ) andOperation Qualification (OQ) services include documentationand performance reports, compressorand sub-system component specifications,microprocessor flow diagrams, softwarespecifications, and with have this require this NEMA Referencethis codeplugreceptacle Plug ReceptacleP15-15P5-15RP25-20P5-20RP35-30 P5-30RP46-15P6-15RP56-20P6-20RP66-30P6-3 0RP7 EuropeanP8 BritishLine cord Plug ReferenceNorth America: North America: USA/Canada +1 866 984 3766 Europe:Austria +43 1 801 40 0, Belgium +32 2 482 30 30, Finland +358 9 329 100, France +33 2 2803 2000, Germany national toll free 08001-536 376, Germany international +49 6184 906940, Italy +39 02 95059 1, Netherlands +31 76 571 4440, Russia/CIS +7 (812) 703 42 15, Spain/Portugal +34 93 223 09 18, Switzerland +41 44 454 12 12, UK/Ireland +44 870 609 9203 Asia:China +86 21 6865 4588 or +86 10 5850 3588, India +91 22 5542 9494, Japan +81 45 453 9220, Other Asian countries +852 2885 4613 Countries not listed:+49 6184 90 6940 or +33 2 2803 2000 2007 Thermo Fisher Scientific Inc.

5 All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for Scientific Revco Freezers-40 C to -150 CSafe, reliable storage for valuable samples and materials501939 COVER:501939_cover 8/28/07 7:37 AM Page 1 BRO-LECS-REVULT-0907 18 Choose from twochest models, withoperating temperatures of -140 C and -150 ULT-10140-9 shown with optionaltemperature recorder.*All dimensions and specifications subject to change without notice. External dimensions include allowances for cabinet door, hinges, latches, handles, and control panel pro-trusions. 1No plug provided; requires hardwire connection by Temperature: -140 Dimensions*Exterior Dimensions*Ship WeightModel No.(L)ElectricalBreaker (Plug)H x D x W inches (mm)H x D x W inches (mm)lb (kg)ULT-10140-9-D208/230V 60Hz 1 (P6)ULT-10140-9-E208/230V 60Hz 3 (HW1) 50Hz 3 (HW1) x x x x (292)200V 50Hz 3 (HW1)(670 x 480 x 890)(1090 x 740 x 1760)(483)ULT-10140-9-V230V 50Hz 1 (HW1)ULT-10140-9-W230V 50Hz 1 (HW1)Revco Ultima II -140 C Cryogenic Chest FreezersOperating Temperature: -150 Dimensions*Exterior Dimensions*Ship WeightModel No.

6 (L)ElectricalBreaker (Plug)H x D x W inches (mm)H x D x W inches (mm)lb (kg)ULT-7150-9-D208/230V 60Hz 1 (P6)ULT-7150-9-E208/230V 60Hz 3 (HW 1) 50Hz 3 (HW1) x x x x (193)200V 50Hz 3 (HW1)(670 x 480 x 590)(1090 x 740 x 1480)(374)ULT-7150-9-V230V 50Hz 1 (HW1)ULT-7150-9-W230V 50Hz 1 (HW1)Revco Ultima II -150 C Cryogenic Chest FreezersThermo Scientific Revco Ultima II MechanicalRefrigeration Delivers Superior UniformityLiquid Nitrogen Vapor StorageMechanically RefrigeratedCryogenic FreezerLiquid Nitrogen (-196 C)-140 C Nominal Setpoint18"18"-162 C-158 C-136 C-136 C-136 C888-136 C-135 C-137 C-76 C-157 C-81 C-82 C-72 CRevco Ultima II IntrLogiccontrols monitor allfunctions for safe,dependable and economical operation;shown with optional LN2backup of temperature distribution in a liquid nitrogen freezer (vapor phase) and mechanically refrigeratedcryogenic freezer ( Revco Ultima II Model ULT10140-9). Graph represents temperatures at relative locationswithin the chamber.

7 Data suggests that 100% of the Ultima II storage space maintains uniform storagetemperatures safely below -130 C, while temperature in LN2vapor system is dependent on storage System Exclusive IntrLogicmicroprocessor control system withtouchpad data entryand digital display ofall functions Setpoint securitysystem with key-operated switch formain power and alarmlocks in temperatureand alarm setpoints Independent operatingtemperature andhigh/low limit alarmfunctions with factory-set defaults for quickstart-up, all setpointsadjustable in 1 Cincrements17 Thermo Scientific Revco Ultima IICryogenic Chest FreezersProtecting Your Precious SamplesResearchers worldwide protect more than two billion samplesinside Thermo Scientific cold storage equipment. With provensolutions including +4 C refrigerators to -196 C cryogenic freezersand Nalgene and Nunc consumables, you re free to concentrateon your work without worrying about your valuable Storage Applications by Operating TemperatureLow -10 C to -40 CUltra-Low -50 C to -86 CCryogenic -140 C to -150 CBacteria Blood component additives Bone marrow Clinical samples Fungi (yeasts/spores/molds) Insect cell culture Mammalian cell culture Materials testing storage Molecular biology enzymes/kits Nucleic acids (DNA/RNA) Plant cell culture Plasma storage Proteins Red cell storage Sperm, fertilized ova Tissues Viruses 501939 COVER:501939_cover 8/28/07 7.

8 38 AM Page 2 All of our freezers, including space-saving uprights and low-profile chest models, share design and technology improvements developed through decades of Scientific Revco FreezersUltra-Low and Cryogenic StorageDesigned for long-term storage of biologicals, blood componentsand pharmaceuticals, our freezers incorporate the latest refrigerationand microprocessor-based control technology developed to increasereliability, stability and cryogenic freezers feature patented orbital refrigeration thatdelivers temperature uniformity as low as -150 , dependableperformance for demandinglaboratory conditionsFeatures and Benefitspages2-5 Revco Ultima IIFreezerspage 6 Revco Elite Freezerspage 10 Revco Value Freezerspage 13 Revco CryogenicStorage Freezerspage 16501939 TEXT:38744 Thermo 8/28/07 7:59 AM Page 1 Advanced Refrigeration TechnologyOur freezers feature the Legaci refrigeration system with fullyintegrated cooling technology for ultra-low temperature Legaci system is more dependable, specifically designedand tested to operate at temperatures from -40 C to -86 C in arugged laboratory environment without exceeding parametersof any sub-component within the Our Legaci system meets or exceeds the highest performance standards in accelerated life testing Sets a new standard for reliability Performs in demandingenvironments Tolerates recurring voltagefluctuations, high ambienttemperatures, heavy traffic in/out of freezerThermo Scientific Revco FreezersOur chest and upright freezers share an advanced technology and design platform with three distinctseries Ultima II, Elite and Value our portfolio offers multiple levels of control sophistication to meet your TEXT:38744 Thermo 8/28/07 7.

9 59 AM Page 2 Advanced Cabinet Construction3 Legaci Refrigeration SystemCustom engineered Copeland compressors, high-performance lubricantsCFC-Free RefrigerantsDuPont Suva 95 in -86 C low-stage modelsDownfeed EvaporatorHeavy-gauge copper for efficient refrigerant flowSound AbatementEnhanced acoustic insulationHeavy Duty CastersFor mobility as requiredWashable FilterProtects condenser finsagainst dust buildup Cabinet InsulationMinimum 5" (127mm) CFC-Freefoamed-in-place urethane, closed-cell, for thermal protection andstructural strengthRemote Alarm ContactsFor physical connection to external alarm/monitor Outer DoorMinimum 3" (76mm) high-strength, foamed-in-placeurethane insulationOuter Door HingesIndependently mounted for each doorAccess Port1" diameter ( ) on rear wall, left cornerInner DoorsHigh-impact plastic with recessed handleInterior ShelvesStainless steel, top shelf fixed, three adjustableInventory RacksOptional, stainless steel with fiberboard boxes anddividersIntrLogic Control Ultima II Series only, doormounted for eye-level controlControl ProbeCenter mounted, rear wall, for accurate temperature controlHot Gas BypassMinimizes frost buildup around door gasketGasketAdvanced two bulb silicone gasket withadded semi bulb (cabinet mounted).

10 Doorgasket enhances additional sealingVoltage BoostBuilt-in, compensates forlow line voltageControllerControl location Elite andValue Series upright modelsRecorderOptional 7-day, 6" (152mm) circular chartPressure Equalization PortCombats vacuum created by pressuredifferential upon door closing, allowingre-entry to cabinet within 30 secondsCryoLatch Integrated door handleand latch, plus optionalCryoSecure proximitycard access (not shown)501939 TEXT:38744 Thermo 8/28/07 7:59 AM Page 3 IntrLogic Microprocessor ControlOur IntrLogic microprocessor control is the industry s most comprehensive management system for temperature control, electrical power, alarm and monitoring functions. IntrLogic provides secure, interactive control to assure the highest level of security for the stored product and refrigeration for Thermo Scientific RevcoUltima II Ultra-Low and Cryogenic Storage FreezersOur IntrLogic control features a standard RS-232 dataport with system software for quick PC installation.


Related search queries