Transcription of Manual Embedded-PC - Beckhoff Automation
1 Manual | ENCX50x0 Embedded-PC9/22/2022 | Version: of contentsCX50x03 Version: of on the on information issue 72 Product - Technical - Technical 203 Assembly and , installation and on the mounting of passive terminals to the power supply of connections (CX50x0-N030).. connections (CX50x0-N031).. 354 cable on and on using the CMOS BIOS Chipset Management Health 6251-second UPS (persistent variables).. write 68 Table of contentsCX50x04 Version: the validity of the 706 Error handling and CPU on the basic CPU of the power supply in K-bus of the power supply in E-bus and and 82 ForewordCX50x05 Version: on the documentationThis description is only intended for the use of trained specialists in control and Automation engineering whoare familiar with applicable national is essential that the documentation and the following notes and explanations are followed when installingand commissioning the components.
2 It is the duty of the technical personnel to use the documentation published at the respective time of eachinstallation and responsible staff must ensure that the application or use of the products described satisfy all therequirements for safety, including all the relevant laws, regulations, guidelines and documentation has been prepared with care. The products described are, however, constantly reserve the right to revise and change the documentation at any time and without prior claims for the modification of products that have already been supplied may be made on the basis of thedata, diagrams and descriptions in this , TwinCAT , TwinCAT/BSD , TC/BSD , EtherCAT , EtherCAT G , EtherCAT G10 , EtherCAT P ,Safety over EtherCAT , TwinSAFE , XFC , XTS and XPlanar are registered trademarks of and licensed byBeckhoff Automation designations used in this publication may be trademarks whose use by third parties for their ownpurposes could violate the rights of the PendingThe EtherCAT Technology is covered.
3 Including but not limited to the following patent applications andpatents:EP1590927, EP1789857, EP1456722, EP2137893, DE102015105702with corresponding applications or registrations in various other is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH,GermanyCopyright Beckhoff Automation GmbH & Co. KG, reproduction, distribution and utilization of this document as well as the communication of its contents toothers without express authorization are will be held liable for the payment of damages. All rights reserved in the event of the grant of apatent, utility model or : instructionsSafety regulationsPlease note the following safety instructions and explanations!
4 Product-specific safety instructions can be found on following pages or in the areas mounting, wiring,commissioning of liabilityAll the components are supplied in particular hardware and software configurations appropriate for theapplication. Modifications to hardware or software configurations other than those described in thedocumentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co. qualificationThis description is only intended for trained specialists in control, Automation and drive engineering who arefamiliar with the applicable national of symbolsIn this documentation the following symbols are used with an accompanying safety instruction or note. Thesafety instructions must be read carefully and followed without fail!
5 DANGERS erious risk of injury!Failure to follow the safety instructions associated with this symbol directly endangers the life and health ofpersons. WARNINGRisk of injury!Failure to follow the safety instructions associated with this symbol endangers the life and health of per-sons. CAUTIONP ersonal injuries!Failure to follow the safety instructions associated with this symbol can lead to injuries to to the environment or devicesFailure to follow the instructions associated with this symbol can lead to damage to the environment or pointerThis symbol indicates information that contributes to better : on information securityThe products of Beckhoff Automation GmbH & Co. KG ( Beckhoff ), insofar as they can be accessed online,are equipped with security functions that support the secure operation of plants, systems, machines andnetworks.
6 Despite the security functions, the creation, implementation and constant updating of a holisticsecurity concept for the operation are necessary to protect the respective plant, system, machine andnetworks against cyber threats. The products sold by Beckhoff are only part of the overall security customer is responsible for preventing unauthorized access by third parties to its equipment, systems,machines and networks. The latter should be connected to the corporate network or the Internet only ifappropriate protective measures have been set addition, the recommendations from Beckhoff regarding appropriate protective measures should beobserved. Further information regarding information security and industrial security can be found in products and solutions undergo continuous further development.
7 This also applies to securityfunctions. In light of this continuous further development, Beckhoff expressly recommends that the productsare kept up to date at all times and that updates are installed for the products once they have been madeavailable. Using outdated or unsupported product versions can increase the risk of cyber stay informed about information security for Beckhoff products, subscribe to the RSS feed at issue on system interface N031 and DVI on temperature range and K-bus for power supply on passive terminals and power supply on K-Bus diagnosis requirements overview Types 1-second UPS reworkedProduct overviewCX50x08 Version: useThe CX5010 / CX5020 device series is a modular control system designed for top-hat rail installation.
8 Thesystem is scalable, so that the required modules can be assembled and installed in the control cabinet orterminal box as switch the PC off after closing the softwareBefore the Embedded PC is switched off, the software currently running on it should be stopped properly inorder to avoid data loss on the hard disk. Please read the section on Switching off [} 40] .Switch off all system components and uncouple the Industrial PC from the system if the PC is not used forcontrol purposes, during a function test. To disconnect first pull the first terminal behind the powersupply unit (optional), then pull the connectors of the fieldbus components that have been switched off must be secured against being switched on Embedded PC s power supply unit must be supplied with 24 to the environment or devicesDo not exchange any parts when under power!
9 Replacing control components while the system is live maylead to short circuits or overvoltages, which in turn may damage the controller and connected peripherals(terminals, monitors, input devices etc.).When components are being fitted or removed, the supply voltage must be switched knowledgeNOTES ystem malfunctionsRequires software knowledge! Each user must be familiar with all the functions of the software installed onthe PC to which he has overviewCX50x09 Version: OverviewThe systemThe CX5000 series devices are DIN rail-mountable, fanless Embedded PCs with direct connection forBeckhoff Bus Terminals or EtherCAT terminals. In contrast to the other CX device families, the CX5000series has a fixed, non-expandable number of system interfaces.
10 The housing design for this series isoptimised for robustness and compactness. No modular expandability for the left-hand side is EtherCAT integration offers a wide range of expansion capability. Further master/slave fieldbusconnections (PROFIBUS, CANopen, DeviceNet) or communication interfaces (RS232, RS422/RS485) andall other signal types accessible via EtherCAT can be directly connected as EtherCAT Terminals. Twoindependent Gigabit Ethernet ports and four USB interfaces are available. A Beckhoff control panel or acommercially available DVI monitor can be connected to the DVI D interface. A serial port (RS232/RS422/RS485) or a fieldbus connection with master or slave function can be added as an optional interface asrequired.