Reference Manual00809-0100-4004, Rev DCMay 2016 Rosemount 8800D Series Vortex Flowmeter1 Reference manual 00809-0100-4004, Rev DCTable of ContentsMay 2016 Table of Contents 1 Section 1: to use this manual .. messages .. description .. 1 2 Section 2: variables .. Variable (PV) .. of Range .. Output .. Variable Units .. setup.. Tag .. configuration .. K-factor .. Type .. ID .. mapping .. Variable Units .. Output .. DSP (Digital Signal Processing) .. 16 3 Section 3: messages .. sizing .. orientation .. material selection .. considerations.. locations .. configuration .. mode vs. saturation output values .. indicator option .. 28 Contents2 Reference Manual00809-0100-4004, Rev DCTable of ContentsMay 2016 Table of body installation tasks .. direction .. bolts.. Flowmeter alignment and mounting .. Flowmeter mounting .. grounding .. considerations .. installations.

Reference Manual 00809-0100-4004, Rev DC Title Page May 2016 Title Page i Rosemount™ 8800D Series Vortex Flowmeter Read this manual before working with the product.

Tags:

  Manual, Series, Rosemount, Vortex, 8800d, Flowmeter, Rosemount 8800d series vortex flowmeter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Manual: Rosemount 8800D Series Vortex Flowmeter

1 Reference Manual00809-0100-4004, Rev DCMay 2016 Rosemount 8800D Series Vortex Flowmeter1 Reference manual 00809-0100-4004, Rev DCTable of ContentsMay 2016 Table of Contents 1 Section 1: to use this manual .. messages .. description .. 1 2 Section 2: variables .. Variable (PV) .. of Range .. Output .. Variable Units .. setup.. Tag .. configuration .. K-factor .. Type .. ID .. mapping .. Variable Units .. Output .. DSP (Digital Signal Processing) .. 16 3 Section 3: messages .. sizing .. orientation .. material selection .. considerations.. locations .. configuration .. mode vs. saturation output values .. indicator option .. 28 Contents2 Reference Manual00809-0100-4004, Rev DCTable of ContentsMay 2016 Table of body installation tasks .. direction .. bolts.. Flowmeter alignment and mounting .. Flowmeter mounting .. grounding .. considerations .. installations.

2 Connections .. installation .. gland .. the transmitter case .. procedure.. electronics .. configuration .. the indicator .. protection .. the transient protector .. 47 4 Section 4: .. Alerts .. Test .. Simulation .. Trim .. Analog Trim .. Frequency at URV .. functionality .. Output .. Compensation .. Fluid Diagnostic .. Mode.. Display .. Processing .. 613 Reference manual 00809-0100-4004, Rev DCTable of ContentsMay 2016 Table of Information .. HART Revisions .. Device .. 66 5 Section 5: messages .. tables .. troubleshooting.. messages .. test points.. Test point 1 .. messages on LCD display .. procedures .. replacement .. the terminal block in the housing .. the electronics boards .. the electronics housing .. the sensor .. the sensor: removable support tube.. electronics procedure .. cable at the electronics housing .. the housing orientation.

3 Sensor replacement (MTA option only).. of material ..95 AAppendix A: Specifications and Reference .. specifications .. specifications .. specifications .. drawings .. 124 BAppendix B: Product .. certifications .. Manufacturing Locations .. enclosure Ex d protection type in accordance with IEC 60079-1, EN 60079-1 ..1414 Reference Manual00809-0100-4004, Rev DCTable of ContentsMay 2016 Table of n protection type in accordance with IEC 60079-15,EN60079-15 .. Directive Information .. Directive .. Pressure Equipment Directive (PED).. Location Certifications .. American Certifications.. Certifications .. IECEx Certifications .. Certifications (NEPSI) .. Certifications (INMETRO) .. Conformity (EAC) ..147 CAppendix C: Electronics messages .. verification .. verification using flow simulation mode .. flow rate simulation .. flow rate simulation .. verification using an external frequency generator.

4 Output variables with known input frequency .. units .. units ..172 DAppendix D: HART Fast KeysReference manual 00809-0100-4004, Rev DCTitle PageMay 2016iTitle PageRosemount 8800D SeriesVor tex FlowmeterRead this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this products described in this document are NOT designed for nuclear-qualified applications. Using non-nuclear qualified products in applications that require nuclear-qualified hardware or products may cause inaccurate information on Rosemount nuclear-qualified products, contact your local Emerson Process Management Sales product is intended to be used as a Flowmeter for liquid, gas, or steam applications. Any use other than for which it was intended may result in serious injury or Manual00809-0100-4004, Rev DCTitle PageMay 2016 Title PageReference manual 00809-0100-4004, Rev DCIntroductionMay 20161 IntroductionSection to use this manualThis manual provides installation, configuration, operation, troubleshooting, and other procedures for the use of the Rosemount 8800D Vortex Flowmeter .

5 For model code ordering information, see the Rosemount 8800D Series Vortex Flowmeter Product Data 2: Configuration contains information on entering and verifying basic configuration 3: Installation contains mechanical and electrical installation 4: Operation contains information on advanced configuration parameters and functions that can aid in maintaining the 5: Troubleshooting provides troubleshooting techniques, diagnostic information, and transmitter verification A: Specifications and Reference Data provides reference and specification B: Product Certifications provides specific information for approval C: Electronics Verification provides a short procedure for verification of electronic output to assist in meeting the quality standards for ISO 9001 certified manufacturing D: HART Fast Keys provides command tree, and Fast Key Sequence tables for the Field Communicator when used in conjunction with the Rosemount messagesProcedures and instructions in this manual may require special precautions to ensure the safety of the personnel performing the operations.

6 Refer to the safety messages, listed at the beginning of each section, before performing any descriptionThe Rosemount 8800D Vortex Flowmeter consists of a meter body and transmitter, and measures volumetric flow rate by detecting the vortices created by a fluid passing by the shedder bar. The meter body is installed in-line with process piping. A sensor is located at the end of the shedder bar which creates a sine wave signal due to the passing vortices. The transmitter measures the frequency of the sine wave and converts it into a flowrate. 2 Reference Manual00809-0100-4004, Rev DCIntroductionMay 2016 Introduction3 Reference manual 00809-0100-4004, Rev DCConfigurationMay 2016 ConfigurationSection 2 ConfigurationProcess variables .. page 3 Basic setup ..page variablesProcess Variables for the Rosemount 8800D provides the Flowmeter output. When commissioning a Flowmeter , review each process variable, its function and output, and take corrective action if necessary before using the Flowmeter in a process Variable (PV)The measured value of the variable mapped to the primary variable.

7 This can be either Process Temperature (MTA option only) or Flow. Flow variables are available as mass, volume, corrected volume, or velocity. When bench commissioning, the flow values for each variable should be zero and the temperature value should be the ambient the units for the flow or temperature variables are not correct, refer to Process Variable Units on page 4. Use the Process Variable Units function to select the units for your of RangeThe primary variable as a percentage of range provides a gauge as to where the measured flow rate of the meter is within the configured range of the meter. For example, the range may be defined as 0 gal/min to 20 gal/min. If the measured flow rate is 10 gal/min, the percent of range is 50 OutputThe analog output variable provides the analog value for the primary variable. The analog output refers to the industry standard output in the 4 20 mA range. Check the analog output value against the actual loop reading given by a multi-meter.

8 If it does not match, a 4 20 mA trim is required. See Analog Trim on page , 2, 1 FastKeys2, 2, 2, 1 FastKeys3, 4, 3, 2 FastKeys3, 4, 3, 14 Reference Manual00809-0100-4004, Rev DCConfigurationMay Variable UnitsAllows for the viewing and configuration of Process Variable Units such as Volume, Velocity, Mass Flow, Electronics Temperature, Process Density, and Corrected Volume units, including corrected volume Special Units FlowAllows the user to view the volumetric flow rate Flow UnitsAllows the user to select the volumetric flow units from the available , 2, 2, 6 FastKeys3, 2, 1 FastKeys2, 2, 2, 6, 1gallons per secondimperial gallons per minutegallons per minuteimperial gallons per hourgallons per hourimperial gallons per daygallons per dayliters per secondcubic feet per secondliters per minutecubic feet per minuteliters per hourcubic feet per hourliters per daycubic feet per daycubic meters per secondbarrels per secondcubic meters per minutebarrels per minutecubic meters per hourbarrels per hourcubic meters per daybarrels per daymega cubic meters per dayimperial gallons per secondspecial units5 Reference manual 00809-0100-4004, Rev DCConfigurationMay 2016 ConfigurationCorrected Volumetric Flow UnitsAllows the user to select the corrected volumetric flow units from the available measuring corrected volumetric flow, a base density and process density must be provided.

9 Mass FlowAllows the user to view the mass flow rate value and units. FastKeys2,2,2,6,2gallons per secondimperial gallons per hourgallons per minuteimperial gallons per daygallons per hourliters per secondgallons per dayliters per minutecubic feet per secondliters per hourstandard cubic feet per minuteliters per daystandard cubic feet per hournormal cubic meters per minutecubic feet per daynormal cubic meters per hourbarrels per secondnormal cubic meters per day barrels per minutecubic meters per secondbarrels per hourcubic meters per minutebarrels per daycubic meters per hourimperial gallons per secondcubic meters per dayimperial gallons per minutespecial unitsFastKeys3, 2, 16 Reference Manual00809-0100-4004, Rev DCConfigurationMay 2016 ConfigurationMass Flow UnitsAllows the user to select the mass flow units from the available list. (1 STon = 2000 lb; 1 MetTon = 1000 kg)NoteIf you select a Mass Flow Units option, you must enter process density in your configuration.

10 Velocity FlowAllows the user to view the velocity flow rate value and units. Velocity Flow UnitsAllows the user to select the Velocity Flow Units from the available Measurement BaseDetermines if the velocity measurement is based on the mating pipe ID or the meter body ID. This is important for Reducer Vortex , 2, 2, 6, 5grams per hourpounds per daygrams per minutespecial unitsgrams per secondshort tons per daykilograms per dayshort tons per hourkilograms per hourshort tons per minutekilograms per minutepounds per secondkilograms per secondtons (metric) per day pounds per minutetons (metric) per hourpounds per hourtons (metric) per minuteFastKeys3, 2, 1 FastKeys2, 2, 2, 6, 3feet per secondmeters per secondFastKeys2, 2, 2, 6, 47 Reference manual 00809-0100-4004, Rev DCConfigurationMay 2016 ConfigurationSpecial UnitsAllows the user to create flow rate units that are not among the standard options. Configuration of a special unit involves entry of these values: base flow unit, base time unit, user defined unit and conversion number.