Example: air traffic controller

MasterProtect HB 400 - Master Builders Solutions

Technical Data Guide 9. 09 97 23. Coatings for Concrete and Masonry MasterProtect HB 400.. Water-based, high-build, 100% acrylic waterproof coating FORMERLY THOROCOAT . PACKAGING DESCRIPTION. 5 gallon ( L) pails MasterProtect HB 400 is a water-based, high-build, 100% acrylic waterproof coating for above-grade concrete, masonry, stucco and EIFS. YIELD. See charts on page 3. STORAGE PRODUCT HIGHLIGHTS SUBSTRATES. Store in unopened containers in a Available in a broad range of colors and Concrete clean, dry area. Keep from freezing textures for design versatility Masonry Resists wind-driven rain, helps prevent water Cement plaster SHELF LIFE. penetration into the substrate Stucco 18 months when properly stored Breathable to allow water vapor to escape EIFS. VOC CONTENT Excellent adhesion, bonds securely to Existing Coatings Less than 100 g/L substrate for long-term durability less water and exempt solvents UV resistance provides excellent color retention for a long lasting attractive finish HOW TO APPLY.

MasterProtect HB 400 is meant to be applied as a two-coat system, achieving a total dry-film thickness (DFT) of 12–16 mils (0.3 mm–0.4 mm). For re-coat applications one coat applied at 11–5 mils (0.279–0.127) DFT. 2.Apply MasterProtect HB 400 by brush, spray, roller, or spray-and-backroll. Spray apply

Tags:

  Applied, Spray, Masterprotect

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MasterProtect HB 400 - Master Builders Solutions

1 Technical Data Guide 9. 09 97 23. Coatings for Concrete and Masonry MasterProtect HB 400.. Water-based, high-build, 100% acrylic waterproof coating FORMERLY THOROCOAT . PACKAGING DESCRIPTION. 5 gallon ( L) pails MasterProtect HB 400 is a water-based, high-build, 100% acrylic waterproof coating for above-grade concrete, masonry, stucco and EIFS. YIELD. See charts on page 3. STORAGE PRODUCT HIGHLIGHTS SUBSTRATES. Store in unopened containers in a Available in a broad range of colors and Concrete clean, dry area. Keep from freezing textures for design versatility Masonry Resists wind-driven rain, helps prevent water Cement plaster SHELF LIFE. penetration into the substrate Stucco 18 months when properly stored Breathable to allow water vapor to escape EIFS. VOC CONTENT Excellent adhesion, bonds securely to Existing Coatings Less than 100 g/L substrate for long-term durability less water and exempt solvents UV resistance provides excellent color retention for a long lasting attractive finish HOW TO APPLY.

2 Excellent hiding power SURFACE PREPARATION. Textured formulations help improve aesthetics 1. Surfaces should be clean and sound and free of irregular substrates of all bond-inhibiting contaminants. Effective carbon dioxide diffusion barrier, 2. Concrete substrates should be fully cured. protects embedded steel from corrosion 3. Repair any holes, spalled and damaged Freeze/thaw resistant, suitable for cold concrete with appropriate Master Builders climates Solutions repair materials. Allow appropriate Low VOC content for broad compliance across cure time prior to coating. all regions 4. Remove any protruding concrete accessories and smooth out any surface irregularities. 5. High-pressure power wash surface (or APPLICATIONS abrasive blast on hard, dense surfaces) to Exterior create a profile of SP 3, per ICRI Guide Vertical and overhead surfaces 6. Some stains may require chemical removal. Above-grade Neutralize any cleaning compounds used and Protecting and waterproofing rinse with clean water.

3 7. Check adhesion of old coatings according to ASTM D 3359, Measuring Adhesion by Tape Test Method A. 8. Remove any blisters or delaminated areas and sand edges to smooth rough areas and provide transition to old paint areas. A brand of Technical Data Guide MasterProtect HB 400. Technical Data Test Data Composition MasterProtect HB 400 SMOOTH. MasterProtect HB 400 is a water-based, high-build, PROPERTY RESULTS TEST METHOD. 100% acrylic waterproof coating. Compliances Density, lbs/gal (kg/L) ( ) ASTM D 1475. Alberta Transportation - Type 3 sealer Solids, % ASTM D 5201. By weight By volume 38. Viscosity, KU 102 110 ASTM D 562 (Stormer). MasterProtect HB 400 FINE. PROPERTY RESULTS TEST METHOD. Density, lbs/gal (kg/L) ( ) ASTM D 1475. Solids, % ASTM D 5201. By weight By volume 49. Viscosity, KU 117 125 ASTM D 562 (Stormer). Gloss, gloss units <3 ASTM D 523. MasterProtect HB 400 COARSE. PROPERTY RESULTS TEST METHOD.

4 Density, lbs/gal (kg/L) ( ) ASTM D 1475. Solids, % ASTM D 5201. By weight By volume 50. Viscosity, KU 117 125 ASTM D 562 (Stormer). MasterProtect HB 400 SMOOTH. PROPERTY RESULTS TEST METHOD. Resistance to wind-driven rain Meets requirement TT-C-555B. no water penetration Accelerated weathering, Passes ASTM G 23, Type D. 5,000 hrs Visual color change, Passes ASTM D 1729. 5,000 hrs Chalking, Passes ASTM D 4214. 5,000 hrs Freeze/thaw resistance, Passed DOT Method A and B. 50 cycles Water-vapor permeance, perms 23 ASTM D 1653. Moisture resistance, Meets requirement: TT-C-555B. no blistering, loss of adhesion, or discoloration Master Builders Solutions Test Data MasterProtect HB 400 SMOOTH, CONTINUED. PROPERTY RESULTS TEST METHOD. Salt spray (fog) resistance, Passed ASTM B 117. 300 hrs Carbon-dioxide diffusion PR EN 1062-6. R (equivalent air-layer thickness), ft (m) 1,318 (402). Sc (equivalent concrete thickness),in (cm) 39 (100).

5 Flexibility, No cracking ASTM D 522. 1 mandrel Dirt pick-up, % ; passed ASTM D 3719. after 6 months exposure Sand abrasion resistance, Passed ASTM D 968 Method A. at 3,000 L. Impact resistance, Passed ASTM D 2794. at 30 in-lbs Fungus resistance No growth ASTM D 3273. Meets requirement Mildew resistance Fed Spec. TT-P-29. Aspergillus oryzae, 7 days No growth (Fed. Std. 141, Method 6152. Aspergillus niger, 21 days No growth and ). Surface burning characteristics ASTM E 84. Flame spread 1. Smoke 4. Fuel contribution 7. Flash point, F ( C) > 200 (93) ASTM D 56 Tag Closed Tester Test results are averages obtained under laboratory conditions. Reasonable variations can be expected. Yield TEXTURE RATE, WET FILM, DRY FILM, FT2/GAL/COAT (M2/L) MILS (MM) MILS (MM). Smooth Recoat 75 125 ( ) 22 13 ( ) 8 5 ( ). Fine or Coarse Recoat 75 125 ( ) 22 13 ( ) 11 6 ( ). Smooth 75 100 ( ) 22 16 ( ) 8 6 ( ). Fine or Coarse 75 100 ( ) 22 16 ( ) 11 8 ( ).

6 *Coverages are estimates for smooth, dense concrete. Coverages will vary on porous or textured surfaces. 9. Treat cracks greater than 1 32" with MasterProtect 2. In multi-pail applications, mix the contents of 2. Apply MasterProtect HB 400 by brush, spray , FL 746 or MasterProtect FL 748. Treat cracks each new pail into the partially used previous roller, or spray -and-backroll. spray apply larger than 1/4 as expansion joints and fill with pail to ensure color consistency and smooth MasterProtect HB 400 Coarse for best results. appropriate Master Builders Solutions sealant. transitions from pail to pail. 3. Maintain proper uniform wet-film thickness 10. New CMU must have a base coat of (WFT) during application to ensure the MasterProtect FL 749. APPLICATION performance characteristics desired (see yield 1. MasterProtect HB 400 is meant to be applied rates section). MIXING INSTRUCTIONS as a two-coat system, achieving a total dry-film 4.

7 Always work to a natural break and maintain a 1. Prior to use, mix MasterProtect HB 400 at slow thickness (DFT) of 12 16 mils ( mm mm). wet edge during application. speed with drill and mixing paddle to ensure For re-coat applications one coat applied at 5. For uniformity of color and texture, application uniform color and aggregate disbursement and 11 5 mils ( ) DFT. techniques must be consistent throughout to minimize air entrapment. the project. Technical Data Guide MasterProtect HB 400. ROLLER. FOR BEST PERFORMANCE HEALTH, SAFETY AND ENVIRONMENTAL. 1. Use a quality 1-1/4 nap roller cover. Do not apply when substrate or ambient Read, understand and follow all Safety Data 2. Completely saturate the roller and keep it temperature is 40 F (4 C) or below or is Sheets and product label information for this loaded with the coating to build the required expected to fall below 40 F (4 C) within 24 product prior to use.

8 The SDS can be obtained mils. Never dry roll. hours after application. by visiting 3. Cross roll, maintaining a wet edge, to achieve Do not apply if rain is expected within 24 hours en-us, e-mailing your request to uniform thickness. Backroll in one direction for of application. or calling 1(800)433-9517. consistent appearance. Not for immersion service. Use only as directed. spray Not intended for use as a horizontal traffic- IN CASE OF EMERGENCY: Call CHEMTEL. 1. Equipment is available for spraying all grades bearing coating. +1 (800) 255-3924 or if outside the US or of MasterProtect HB 400. For fine and coarse Apply a 4 by 4 ft ( by m) test area to Canada, +1 (813) 248-0585. textures, it is necessary to use a heavy- verify acceptable color, texture and adhesion duty sprayer designed for the application before proceeding with any project. The test of coatings that contain sand particles. method for measuring adhesion is ASTM D.

9 Contact equipment manufacturer for further 3359, Measuring Adhesion by Tape Method A. recommendations. On the 0 5 scale, a minimum adhesion rating 2. For smooth and fine grades, backrolling of 4A is required. in one direction after spray application is Color formulas containing organic colorants recommended to achieve uniform texture and are susceptible to fading in exterior film thickness. applications. Refer to Technical Support for guidance. BRUSH. Do not thin the material. 1. Application by brush is recommended only for For professional use only; not for sale to or use small inaccessible areas, , on touch-ups. by the general public. 2. Use only a nylon brush. Make certain the most current versions of product data sheet and SDS are being used;. DRYING TIME. visit Times assume 70 F (21 C) and 50% relative to verify the most current versions. humidity. Proper application is the responsibility of the To touch: 1 2 hours user.

10 Field visits by Master Builders Solutions To recoat: minimum of 6 hours personnel are for the purpose of making Lower surface or air temperatures and higher technical recommendations only and not for relative humidity will extend the drying time. supervising or providing quality control on the jobsite. CLEAN UP. Clean all tools and equipment immediately with water. Cured material may be removed by mechanical means. Master Builders Solutions LIMITED WARRANTY NOTICE Purchaser must determine the suitability of the Master Builders Solutions Construction products for the intended use and assumes Systems US, LLC ( Master Builders ) warrants all risks and liabilities in connection therewith. this product to be free from manufacturing This information and all further technical advice defects and to meet the technical properties are based on Master Builders Solutions 's on the current Technical Data Guide, if used present knowledge and experience.