Example: stock market

Measuring Amplifier System - hottinger.sk

Measuring enSystem devices*)Mains supplySupply voltageMax. input nominal (rated) currentStart-up currentV ACAA115 V/230 V 25+15 % <20 Battery supplyBattery voltageMax. input nominal currentStart-up currentV DCAA12 V/24 V 25+15 % <20 Max. power consumptionW150 Nominal (rated) temperature range C [ F] slots, desktop housing 10 .. +55 [+14 .. +131]19 rack frame 10 .. +55 [+14 .. +131]Type of protectiondesktop housing IP2019 rack frame IP20 Dimensions desktop housing (w x h x d in mm) (1 mm = inches)Desktop housingRack frameMax. number of slotsSupply voltage(V)Weight, approx. (kg)TG/ERTG001D 6230 V (115)6TG010D 6 (with AB32)230 V (115)8TG002D 612/24 =6TG003 DER003D16230 V (115)7/6TG004 DER004D1612/24 = 2230 V (115)5*)The MGCplus System is tested according to the harmonized European standards EN61326 and EN61010 Therefore it achieves the protectionaims of EEC directive 89/336 EEC in the field of electromagnetic compatibility and EEC directive 73/23/EEC in the field of electrical safety oflow voltage equipment.

System devices*) Mains supply Supply voltage Max. input nominal (rated) current Start-up current V AC A A 115 V/230 V −25+15 % 2.2/1.3 <20 Battery supply

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Measuring Amplifier System - hottinger.sk

1 Measuring enSystem devices*)Mains supplySupply voltageMax. input nominal (rated) currentStart-up currentV ACAA115 V/230 V 25+15 % <20 Battery supplyBattery voltageMax. input nominal currentStart-up currentV DCAA12 V/24 V 25+15 % <20 Max. power consumptionW150 Nominal (rated) temperature range C [ F] slots, desktop housing 10 .. +55 [+14 .. +131]19 rack frame 10 .. +55 [+14 .. +131]Type of protectiondesktop housing IP2019 rack frame IP20 Dimensions desktop housing (w x h x d in mm) (1 mm = inches)Desktop housingRack frameMax. number of slotsSupply voltage(V)Weight, approx. (kg)TG/ERTG001D 6230 V (115)6TG010D 6 (with AB32)230 V (115)8TG002D 612/24 =6TG003 DER003D16230 V (115)7/6TG004 DER004D1612/24 = 2230 V (115)5*)The MGCplus System is tested according to the harmonized European standards EN61326 and EN61010 Therefore it achieves the protectionaims of EEC directive 89/336 EEC in the field of electromagnetic compatibility and EEC directive 73/23/EEC in the field of electrical safety oflow voltage equipment.

2 Mechanical stress is tested according to European Standard EN60068 2 6 for vibrations and EN60068 2 27 forshock. The equipment is exposed to an acceleration of 25 m/s2 within the frequency range of Hz in all 3 axes. Duration of this vibrationtest: 30 min per axis. The shock test is performed with a rated value of 200 m/s2 acceleration during 11 ms, half sine pulse shape, with 3shocks in each of the 6 possible rack module ER 003D/004D (482x133x375)Desktop housing TG 009D (173x171x367)Desktop housing TG 001D/002D (255x171x367)Desktop housing TG 010D/003D/004D (458x171x367) enHBM3 System devices MGCsplit1 NT650/1 NT651 power packsInput voltage range, nominalV DCV DC10 .. 5012, 24 and 42 (suitable for all common automotive vehicle electrical systems)Output voltageV DC28 " 2%Max. continuous output currentA3,5 Max. number of connectableMGCsplit modules 10 ( 1x SH400CP, 9x SH400 or SH650;one module less, if an ABX22 is connected)Ride through start upIntrusion at > only:Intrusion at < s(ride through times without measurement System failure)unlimitedmin.

3 10 Voltage discontinuityNT650:NT651:ssmsms(typical ride through times without measurement System failure)10at full load (100 W)60at a load of 1x SH400CP42+ 2x SH65015at full load (100 W)50at a load of 1x SH400CP42+ 2x SH650 Start from standby mode Via CAN message and digital control signalPower consumption at standby modeW< hardware bus linkBaud rate kBits/sStandard CAN as per ISO11898250 Electrical isolation of digital inputV DC500, typicallyInput voltage range of digital inputV DC0 .. 50 Input current of digital inputmA< 3 Low level of digital inputV< 1 High level of digital inputV> 3 Protection against false operation Sustained short circuit proof, polarity reversal protection,cutoff at excess temperatureDegree of protection IP65 Operating temperature range C 30 .. +70 Nominal temperature range C 20 .. +60 Permissible relative humidity%100 Connections Power supplySplit line IN / OUTCAN / digital inputConnection techniquePower supplySplit line IN / OUTCAN / digital input ODU Minisnap, series B, design S3, size 24 pin, 60 coding (suitable connector for cable S32 BFC T04 LPH0 6000)16 pin, no coding (suitable connector for cable S32B0C T16 PFG0 7500)6 pin, 30 coding (suitable connector for cable S32 BAC T06 MPH0 6000) (W x H x D)mm104 x 146 x enHBM4 Modules *)1 SH4001 SH6501 SH400 CPFunctionEnclosure for one MLxx Amplifier and max.

4 Two connectionboards (each 4 divs wide)Enclosure for thecommunication processorDegree of protectionIP40IP65IP40 Operating temperature range C [ F] 30 .. +70 [ 22 .. +158] 30 .. +70 [ 22 .. +158] 20 .. +60 [ 4 .. +140]Nominal (rated) temperaturerange C [ F] 20 .. +60 [ 4 .. +140]Permissible relative humidity%95 at 40 C [104 F]10095 at 40 C [104 F]Supply voltageV18 ..32 Connections S Split Line Input/OutputS As on the resp. connectionboardsS Split Line Input/OutputS ODU connectors (Lemo compatible)S Connection for ABX22AS With CP22 and CP42:100 Mbit-Ethernet; USB;RS-232-CWeight without Amplifier andconnection board, (W x H x D)mm104 x 146 x 205*)See MGCplus System specifications for measurement properties of Amplifier lengthm25 (from 1 SH400CP through last module)Max. number of measurementmodules 16 Baud ,200; 4 byte format (like MGCplus)Bus termination Connected enHBM5 Enclosure dimensions MGCsplit (in mm; 1 mm = inches)Mounting dimensions MGCsplit (in mm; 1 mm = inches)Rear mountingLateral enHBM6 General technical data single-channel Amplifier (4 divs)1)Maximum sampling rate without linearisationvalues/s19200 Limit value switchesNumberReference levelReference voltage (freely adjustable)Hysteresis factory settingAdjustment accuracy %%% 4 Gross, net, peak values 100.

5 +100 of Measuring range1 of Measuring of Measuring rangeResponse Butterworth filter > 5 Hzand Bessel filter > HzPeak value storeNumberFunctionPeak combine 2 Maximum, minimumPeak-peak, averageUpdate time s30 with Butterworth filter > 250 Hzand Bessel filter > 100 HzClearing the peak value stores (switching to current value)within 1 ms, via control inputsHolding of the current value/peak valuewithin 1 ms, via control inputsTime constant for envelope curve .. 10000 Control contacts (HCMOS)Inputs (8 lines, connectable as desired) Permissible input voltageHigh levelLow levelSchmitt-trigger, hysteresisPull-up resistorsVVVVk to + + + > (limit value switch, error)High level with max. 1 mALow level with max. mAInternal resistanceVVk > < (rated) temperature range Service temperature range Storage temperature range C [ F] C [ F] C [ F] 20 ..+60 [ 4 .. +140] 20 ..+60 [ 4 .. +140] 25 ..+70 [ 13 .. +158]Operating voltagesV" ; (< 120 mA)" ; (< 120 mA)2)+ ; (< 150 mA)Card format (Euro)Weightmmg100 x 160300 Connection plugIEC 603-2 indirectlyAnalog outputs Vo1 and Vo2 Nominal (rated) voltagePermissible load resistanceInternal resistanceThe two output voltages can be used to display the five signal voltages.

6 Vk "10 V (asymmetrical)> 5< 5 Amplifier output with zero balanceOutput staggered by the tare valuePeak value store 1 output (maximum or minimum)Peak value store 2 output (maximum or minimum)Peak value store 3 output (peak combine of 1 and 2)Max. deviation of the analog outputs from thedigital valuemV< 3 (< 10 with ML10B)Monitor output for Vo1 via BNC plug on front panelNominal (rated) voltage Permissible load resistanceInternal resistanceVk k "10 (asymmetrical)> 10001 Effect of a 10K-change of the ambient temperature(effect additional to digital value)on the outputs Vo1 and Vo2:sensitivityzero point%mV< , typ. < 3 typ. 21)With ML38B: mm (8 divs)2)Also connectable to "16 enHBM7ML01B single-channel Amplifier modulesAccuracy amplifierInput for voltage measurementsymmetricalInput signal range (selectable) Measuring range (digitally adjustable) Zero offset Measuring frequency rangeVVVHz ..+ ..+ " .. " .. "10" .. 2400 -1 dB1)0 .. 250 1 dBInternal resistance of the signal voltage sourcek < for thermocouple measurementMeasuring range (digitally adjustable)Linearisation error (with AP09 connection board)Linearisation rangeNiCr-Ni (K)Fe-CuNi (J)Cu-CuNi (T)NiCr-CuNi (E)NiCrSi-NiSi (N)Pt10Rh-Pt (S)Pt30Rh-Pt6Rh (B)Pt13Rh Pt(R) C, [ F] C C C C C C C C C C10.

7 3275, [50 .. 5927]< < (K, J, T, E, N)< (S, B, R) 158 .. +1414 191 .. +1414 167 .. +1192 190 .. +1192 210 .. +393 237 .. +393 161 .. +1005 205 .. +1005 186 .. +1300 219 .. +1300+181 .. +1755 50 .. +1755+570 .. +1814+160 .. +1814+178 .. +1769 50 .. +1769 Max. internal resistancek range for cold junction 2) C, [ F] 20 ..+ 60, [ 4 ..+140]Max. permissible common-mode voltageV62 Input for current measurementasymmetrical (to an internal 50 standard resistor)Input signal rangeMeasuring range (digitally adjustable) Max. Measuring frequency rangeZero offset, adjustable ( living zero point)mAmAHzmA 50 ..+50"4 .. 500 .. 2400 -1 dB 0 ..50 Measuring frequency rangeButterworth low passNom. val. fc 1dB 3dB Phase del. Rise time Over- (Hz)(Hz)(Hz)(ms)(ms)shoot %2400 3) 3) 4) low passNom. val. fc 1dB 3dB Phase del. Rise time Over- (Hz) (Hz) (Hz) (ms) (ms)shoot %11004) 1100 *) 300046000 High-pass5)from Hz Be; 5 Hz Bufrom Hz Be; 5 Hz Bufrom 20 Hz Be; 40 Hz calibration deviation% )Linearity deviation%< typ.

8 % of full scale 7)Noise rel. to input with filter : 75 mVMR: 10 V VPP VPP37540120 ThermocouplesType K, J, T, E, NType S, B, RKKtyp. 1*)Factory setting1)With VI > Vpp, note limited Measuring frequencies2)Cold junction included in AP09 connection board3)Valid for VIpp < V with Range = 10 V ( )Valid for VIpp < 5 V with Range = 10 V (corresp. to 50 % modulation of range)5)In the case of resistance thermometers and 6) % with current measurementthermocouples: no function7)For Measuring ranges > 3 V or > 25 mV or > 10 mA; otherwise < % of full 25 % modulation of range) enHBM8ML01B single-channel Amplifier module (continued)Long-term drift over 48 hours (Autocalibration on / off)Meas. range 75 mVMeas. range 10 V VmV5 / / 1 Thermocouples (Autocalibration on / off)Type J, TType E, K, NType S, B, / / 11 / 2 Effect of a 10 K-change of the ambient temperature onthe digital signals S1 and S2with autocalibration on / offSensitivityZero point10 V range75 mV range20 mA rangeThermocouplesType J, TType E, K, NType S, B, R%mV V AKKK< typ.

9 / < < / < 6< 5 / < 50< 4 / < / / 51 / 10 Analog outputs Vo1 and Vo2 Residual carrier voltage ( kHz)Long-term drift (over 48 h)mVPPmV< 12< 3ML10B single-channel Amplifier moduleAccuracy exitation voltage (" 5 %) half and full bridges, potentiometers, piezoresistivetransducersV *) quarter bridgePiezoelectric transducerCurrent-fed piezoelectric transducers ( Deltatron from Br el&Kjaer)In conjunction with AP14 connection boardIn conjunction with AP08 connection boardIn conjunction with AP18 connection boardPerm. cable length between transducer and amplifiermmax. 5001)DC amplifierMeasuring rangesStrain gages (Low)Potentiometers, piezoresistive transducers (High)mV/VmV/V" " " " " " " " amplifiersVoltage input with max. " V amplitudeBridge balancing rangeStrain gages (Low)Potentiometers, piezoresistive transducers (High)mV/VmV/V" "306" "612" "1224" "3060 Charge amplifiersV" VMeasuring frequency rangeButterworth low passNom. val. fc -1dB-3dB Phase del.

10 Rise timeOvershoot(Hz)(Hz)(Hz)(ms)(ms)% ) *)Factory setting1)100 m max. distance between connection board and T-ID/TEDS module2)For a max. of 25 % modulation (UAPPmax=5 V) enHBM9ML10B single-channel Amplifier module (continued) Measuring frequency rangeBessel low passNom. val. fc -1dB-3dB Phase del. Rise timeOvershoot(Hz)(Hz)(Hz)(ms)(ms)%Analog output only(Digital interface 5000 Hz Butterworth)100000111000 188000 (High)100000104000 145000 (Low)5000049000 84000 *) Hz Be; 5 Hz Bufrom Hz Be; 5 Hz Bufrom 20 Hz Be; 40 Hz permissible common-mode voltageV"6 Common-mode-rejectionStrain gagesPotentiometersLinearity deviationLong-term drift over 48 hours (Autocalibration on/off)Interference voltages at the outputNoise related to the inputwith Bessel low pass1000 00 Hz50 000 Hz10 000 Hz1000 Hz100 HzdBdB% V/V V/Vpp>120 (DC)> 95 (DC)< typ. full scale< gagePotentiometer( mV/V)( mV/V)430031) of a 10 K-change of the ambient temperature onthe digital signals S1 and S2 Strain gage (Low):sensitivityzero pointPotentiometer (High):sensitivityzero pointLong-term drift over 48 hoursStrain gage (Low):Potentiometer (High):% V/V% V/VmV/VmV/Vwith autocalibrationon:< < < <30< <20with autocalibrationoff:< <10< <500<5<400 Analog outputs Vo1 and Vo2 Residual carrier voltagemVpp<5 Long-term drift (over 48 h)mV<3*)Factory setting1)For half bridge 20 V/V.