Example: quiz answers

MHT - SOFIMA HYD

MHTHIGH PRESSURE INLINE FILTERP ressure FiltersMHT42 MPa (420 bar)Port sizes: 1/2 1 1/2 Flow rates: 10 420 l/minTECHNICAL DATAMax. working pressure: 42 MPa (420 bar)Max. testing pressure: 62 MPa (620 bar)Min. bursting pressure: 126 MPa (1260 bar) Fatigue test: 0 28 MPa (280 bar)Bypass valve: standard p 600 kPa (6 bar) 10%Reverse fl ow valve: available on requestFilter element collapse pressure: p 2,1 MPa (21 bar) all types p 21 MPa (210 bar) 2T - 2C - 2D - 2V - TD - TV - TT - TSWorking temperature: -25 C +110 CMATERIALSHead: cast ironBowl: forged steelSeals: standard NBRon request FKMCOMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4).

Technical data subject to variations without prior notice. MHT 07/2013 DIRT HOLDING CAPACITY (g) ISO MTD ∆p = 500 kPa (5 bar) FILTER AREA 2) MHT

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of MHT - SOFIMA HYD

1 MHTHIGH PRESSURE INLINE FILTERP ressure FiltersMHT42 MPa (420 bar)Port sizes: 1/2 1 1/2 Flow rates: 10 420 l/minTECHNICAL DATAMax. working pressure: 42 MPa (420 bar)Max. testing pressure: 62 MPa (620 bar)Min. bursting pressure: 126 MPa (1260 bar) Fatigue test: 0 28 MPa (280 bar)Bypass valve: standard p 600 kPa (6 bar) 10%Reverse fl ow valve: available on requestFilter element collapse pressure: p 2,1 MPa (21 bar) all types p 21 MPa (210 bar) 2T - 2C - 2D - 2V - TD - TV - TT - TSWorking temperature: -25 C +110 CMATERIALSHead: cast ironBowl: forged steelSeals: standard NBRon request FKMCOMPATIBILITY (ISO 2943)Full with fl uids: HH-HL-HM-HV-HTG (according to ISO 6743/4).

2 For fl uids different than the above mentioned, please contact our Sales tests performed according to the following standards: ISO 2941: Element collapse resistance testISO 2942: Production integrity testISO 2943: Fluids compatibilityISO 3723: End load test methodISO 3724: Flow fatigue resistance methodISO 3968: Pressure drop versus fl ow rateISO 16889: Multipass test. For further information contact our Technical FiltersMHTA ccessoriesXXXXXXXX = Not available XXType Type151152153-301302--801802803804 MHTCCHS ealsSeals1212121 = NBR Nitrile 2 = FKM Fluoroelastomer1 = NBR Nitrile 2 = FKM FluoroelastomerFilter media Filter media FTFCFDFVCDCVRDMV2T2C2D2 VTDTVFTFCFDFVCDCVRDMV2T2C2D2 VTDTVFTFCFDFVCDCVRDMV 2T2C2D2 VTDTVFT = 5 m(c) FC = 7 m(c)FD = 12 m(c)FV = 21 m(c)CD = 10 CV = 25 RD = 10 MV = 25 2T = 5 m(c)2C = 7 m(c)2D = 12 m(c)2V = 21 m(c)

3 TD = 10 TV = 25 Inorganic fiber >1000 Inorganic fibres >200 PaperSteel wire meshSteel wire mesh p = 21 MPa (210 bar)IndicatorsPort size34----45----5673 = 1/2 4 = 3/4 5 = 1 ( * )6 = 1 1/47 = 1 1/2 (H7 not available)Bypass type SC--SCRPSCRPS = Without C = 600 kPa (6 bar)R = Reverse flow valveP = 600 kPa (6 bar) + option RPorts BNS--BNSFHBNSFHB = BSPN = NPT (N3 not available)S = SAEF = SAE flange 3000 psiH = SAE flange 6000 psi( * ) = F5 only for MHT30+, H5 > MHT30+ not available F5/H5 > MHT80+ not availableOn request only Inorganic fiber >1000 - p = 21 MPa (210 bar)FT = 5 m(c) FC = 7 m(c)FD = 12 m(c)FV = 21 m(c)CD = 10 CV = 25 RD = 10 MV = 25 2T = 5 m(c)2C = 7 m(c)2D = 12 m(c)2V = 21 m(c)TD = 10 TV = 25 Inorganic fiber >1000 - p = 210 bar (21 MPa)03 = Port, plugged5E = Visual differential 500 kPa (5 bar) 5F = Visual differential 800 kPa (8 bar)6E = Electrical differential 500 kPa (5 bar)6F = Electrical differential 800 kPa (8 bar)

4 7E = 6E with LED 7F = 6F with LED T2 = Electrical 500 kPa (5 bar) with thermostat 30 CT3 = Electrical 800 kPa (8 bar) with thermostat 30 C035E5F6E6F7E7FT2T3035E5F6E6F7E7FT2T3035 E5F6E6F7E7FT2T3 Indicator 72 - 73on request only When the filter is ordered with FKM seals, the first digit of the indicator codeis a letter (please see page 188-189).Inorganic fiber >1000 PaperSteel wire meshSteel wire mesh p = 21 MPa (210 bar)Inorganic fiber >1000 - p = 21 MPa (210 bar)HOW TO ORDER THE COMPLETE FILTERHOW TO ORDER THE FILTER ELEMENTP ressure FiltersMHTMHT 151 MHT 152 MHT 153 MHT 301 MHT 302 MHT 801 MHT 802 MHT 803 MHT 8041/2 - 3/4 1/2 - 3/4 1/2 - 3/4 3/4 - 1 3/4 - 1 1 -1 1/4-1 1/21 -1 1/4-1 1/21 -1 1/4-1 1/21 -1 1/4-1 1/28686869494128128128128166196296226317 2453374575587910920911620710719931942087 8787112112138138138138242424353544444444 6363637777949494948888881081081431431431 4346464665658888888812,512,512,5==434343 4310010010010010010010010010004,404,605, 206,608,211,013,917,222.

5 0 Weight KgTypeD1D2H1H2H3H4H5L1L2L4RL3M85/16 18 UNCM107/16 14 UNCMHT 15 ..MHT 30 ..H5H3H2H1RH4D17,430L1L4L3L2D2RD1L3L2D23 0H5H4H3H2H1L1L4L1 123L3L2D2H5H4D1H3H2H1R30 MHT 80 ..MHT 804 Indicator PortIndicator PortIndicator PortDIMENSIONAL LAYOUT(mm)Pressure FiltersMHTH4F5H6 F6F7 TypeMHT 30 MHT 80 3/4 1 1 1/41 1/41 1/2(420 bar )(210 bar)( 420 bar)( 210 bar)(210 bar )42 MPa21 MPa42 MPa21 MPa21 MPa50,8 52,4 66,7 58,7270,0 23,8 26,2 31,830,1835,714 14 19 1919 CodeD1 Max PressureL5L6T (min. thread depth)D3M10 M14M10M1223164,5304835M20 x 1,5 NBRFKMD ifferential ELECTRICAL indicators6 ESetting 500 kPa (5 bar)CE6 FSetting 800 kPa (8 bar)CFRecommended tightening torque 90 NmSPDT differential switch.

6 14 - 30 V: > max resistive or inductive load 4 - 3 A 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650GR231+ ,5304835M20 x 1,5 NBRFKM7 ESetting 500 kPa (5 bar)EE7 FSetting 800 kPa (8 bar)EFRecommended tightening torque 90 NmSPDT differential switch. 14 - 30 V: > max resistive or inductive load 4 - 3 A 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential ELECTRICAL indicators with LED (24 V) for visual indication705932M20 x 1,5O30 CNBRFKMT2 Setting 500 kPa (5 bar)DET3 Setting 800 kPa (8 bar)DFRecommended tightening torque 90 NmSPDT differential switch.

7 14 - 30 V: > max resistive or inductive load 4 - 3 A 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential ELECTRICAL indicators with THERMOSTAT 30 CO30 C704830M20 x 1,5 NBRFKM72 Setting 500 kPa (5 bar)E273 Setting 800 kPa (8 bar)E3 Recommended tightening torque 90 NmSPDT differential switch. 14 - 30 V: > max resistive or inductive load 4 - 3 A 125-250 V: > max resistive or inductive load 1 A - Protection IP65 - Connector DIN 43650 Differential VISUAL ELECTRICAL indicatorsCLOGGING INDICATORS35,530 30M20 x 1,5 NBRFKM5 ESetting 500 kPa (5 bar)AE5 FSetting 800 kPa (8 bar)AFRecommended tightening torque 90 NmDifferential VISUAL indicatorsFLANGE MOUNTING BOLT DIMENSIONS(mm)Pressure FiltersMHTFLOW RATES(l/min)

8 Type pMHT 151 Port 3/4 MHT 152 Port 3/4 MHT 153 Port 3/4 FTFCFDFVCDCVRDMVTDTV2T2C2D2 VFTFCFDFVCDCVRDMVTDTV2T2C2D2 VFTFCFDFVCDCVRDMVTDTV2T2C2D2V11141931457 5708068789121627151825405080758573831315 2235222435557285809078902022315021263860 7590909090901923335030355068809090909090 2630466035415583909090909090333850782840 5785909090909090253552774550759090909090 9090414770855056859090909090909048528190 Filter MediaType pMHT 301 Port 1 MHT 302 Port 1 MHT 801 Port 1 FTFCFDFVCDCVRDMVTDTV2T2C2D2 VFTFCFDFVCDCVRDMVTDTV2T2C2D2 VFTFCFDFVCDCVRDMVTDTV2T2C2D2V25273962801 1010012097117232436573438507512213513014 8127144303447703946791051592191781861501 5527365073556273110130150150150150150515 8671006373841191501501501501501506068781 0973911541942402402402402402404862981307 0819515015015015015015015067769014579901 0415015015015015015015074861001501241421 932402402402402402402407487131184 Filter MediaType pMHT 802 Port 1 1/2 MHT 803 Port 1 1/2 MHT 804 Port 1 1/2 FTFCFDFVCDCVRDMVTDTV2T2C2D2 VFTFCFDFVCDCVRDMVTDTV2T2C2D2

9 VFTFCFDFVCDCVRDMVTDTV2T2C2D2V93128163201 2392792612912172427112512515313114017022 5290320311335260280109116141187173188237 3123303403313552772951441561972601982182 8630030030030030030015215216723028027028 7325380420420420420420420225239270316351 3634104204204204204204204202923023413902 5028130030030030030030030030019021628030 0340350420420420420420420420420283291408 4204204204204204204204204204204203103624 20420 Filter Media50 kPa(0,5 bar)50 kPa(0,5 bar)50 kPa(0,5 bar)150 kPa(1,5 bar)150 kPa(1,5 bar)150 kPa(1,5 bar)100 kPa(1 bar)100 kPa(1 bar)100 kPa(1 bar)The reference fluid has a kinematic viscosity of 30 cSt and a density of 0,86 different oil viscosity please contact our Sales Department for further FiltersMHTT echnical data subject to variations without prior notice.

10 MHT 07/2013 DIRT HOLDING CAPACITY(g) ISO MTD p = 500 kPa (5 bar)FILTER AREA(cm2)TypeCCH 151 CCH 152 CCH 153 CCH 301 CCH 302 CCH 801 CCH 802 CCH 803 CCH 804 2,03,05,55,710,911,922,028,039,12,03,05, 55,710,911,916,125,333,32,63,87,27,514,1 15,527,637,949,42,63,87,27,514,111,320,7 32,242,53,03,97,88,215,617,231,042,556,3 3,03,97,88,215,612,623,036,848,34,36,211 ,512,121,825,346,062,180,54,36,211,512,1 21,818,433,352,970,1FT2 TFC2 CFD2 DFV2 VFilter MediaTypeCCH 151 CCH 152 CCH 153 CCH 301 CCH 302 CCH 801 CCH 802 CCH 803 CCH 804 3004308057701455171031605020658030043080 5770145517103160502065803004308057701455 1430221035604700300430805770145514302210 3560470031047591597517851720269543255685 31047591597517851720269543255685 RDTDTVCDCVMVF ilter MediaPressure FiltersMHT


Related search queries