configuration and Use ManualMMI-20020944, Rev ACApril 2016 Micro Motion Compact Density Meters (CDM) configuration and Use ManualSafety messagesSafety messages are provided throughout this manual to protect personnel and equipment. Read each safety message carefullybefore proceeding to the next Flow customer serviceEmail: Worldwide: Asia-Pacific: and South AmericaEurope and Middle EastAsia PacificUnited 240 1978 Australia800 158 727 Canada+1 303-527-5200 The Netherlands+31 (0) 704 136 666 New Zealand099 128 804 Mexico+41 (0) 41 7686 111 France0800 917 901 India800 440 1468 Argentina+54 11 4837 7000 Germany0800 182 5347 Pakistan888 550 2682 Brazil+55 15 3413 8000 Italy8008 77334 China+86 21 2892 9000 Venezuela+58 26 1731 3446 Central & Eastern+41 (0) 41 7686 111 Japan+81 3 5769 6803 Russia/CIS+7 495 981 9811 South Korea+82 2 3438 4600 Egypt0800 000 0015 Singapore+65 6 777 8211 Oman800 70101 Thailand001 800 441 6426 Qatar431 0044 Malaysia800 814 008 Kuwait663 299 01 South Africa800 991 390 Saudi Arabia800 844 9564 UAE800 0444 0684 ContentsPart IGetting StartedChapter 1 Before you begin.

Configuration and Use Manual MMI-20020944, Rev AC April 2016 Micro Motion® Compact Density Meters (CDM) Configuration and Use Manual

Tags:

  Manual, Configuration, Meters, Density, Density meter, Configuration and use manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Micro Motion Compace Density Meters (CDM) …

1 configuration and Use ManualMMI-20020944, Rev ACApril 2016 Micro Motion Compact Density Meters (CDM) configuration and Use ManualSafety messagesSafety messages are provided throughout this manual to protect personnel and equipment. Read each safety message carefullybefore proceeding to the next Flow customer serviceEmail: Worldwide: Asia-Pacific: and South AmericaEurope and Middle EastAsia PacificUnited 240 1978 Australia800 158 727 Canada+1 303-527-5200 The Netherlands+31 (0) 704 136 666 New Zealand099 128 804 Mexico+41 (0) 41 7686 111 France0800 917 901 India800 440 1468 Argentina+54 11 4837 7000 Germany0800 182 5347 Pakistan888 550 2682 Brazil+55 15 3413 8000 Italy8008 77334 China+86 21 2892 9000 Venezuela+58 26 1731 3446 Central & Eastern+41 (0) 41 7686 111 Japan+81 3 5769 6803 Russia/CIS+7 495 981 9811 South Korea+82 2 3438 4600 Egypt0800 000 0015 Singapore+65 6 777 8211 Oman800 70101 Thailand001 800 441 6426 Qatar431 0044 Malaysia800 814 008 Kuwait663 299 01 South Africa800 991 390 Saudi Arabia800 844 9564 UAE800 0444 0684 ContentsPart IGetting StartedChapter 1 Before you begin.

2 This manual .. codes and device types .. tools and protocols .. documentation and resources ..5 Chapter 2 Quick start .. up the transmitter .. meter status .. a startup connection to the transmitter .. the meter .. the meter using the display .. the meter using ProLink III .. the meter using the Field Communicator ..11 Part IIConfiguration and commissioningChapter 3 Introduction to configuration and commissioning .. values .. default values .. access to the off-line menu of the display .. HART security .. the HART lock .. the factory configuration ..19 Chapter 4 Configure process measurement .. the calibration factors .. factors .. line Density measurement .. Density Measurement Density Damping .. Density two-phase flow parameters .. temperature measurement .. Temperature Measurement Temperature Temperature the pressure input.

3 The pressure input using ProLink III .. the pressure input using the Field Communicator .. for Pressure Measurement up the API referral application ..37 ContentsConfiguration and Use manual up the API referral application using ProLink III .. up the API referral application using the Field Communicator .. up concentration measurement .. to set up concentration measurement .. up concentration measurement using ProLink III .. up concentration measurement using the Field Communicator .. equations to calculate specific gravity, Baum , Brix, Plato, and Twaddell .. switching .. up flow monitoring .. velocity measurement .. volume flow rate measurement .. Flow Flow 5 Configure device options and preferences .. the transmitter display .. the language used for the display .. the process variables and diagnostic variables shown on the display .. the number of decimal places (precision) shown on the display.

4 The refresh rate of data shown on the display .. or disable automatic scrolling through the display variables .. or disable the Acknowledge All Alerts display command .. security for the display menus .. alert handling .. Fault Alert informational parameters .. 83 Chapter 6 Integrate the meter with the control system .. Channel B .. the mA output .. mA Output Process Lower Range Value (LRV) and Upper Range Value (URV) .. Added mA Output Fault Action and mA Output Fault the discrete output .. Discrete Output Discrete Output Discrete Output Fault an enhanced event .. HART/Bell 202 communications .. basic HART parameters .. HART variables (PV, SV, TV, QV) .. burst communications .. Modbus communications .. Digital Communications Fault for Digital Communications Fault 7 Complete the configuration .. or tune the system using sensor simulation.

5 Up transmitter configuration .. HART security ..108 ContentsiiMicro Motion Compact Density Meters (CDM)Part IIIO perations, maintenance, and troubleshootingChapter 8 Transmitter operation .. the process variables .. process variables and diagnostic variables .. process variables using the display .. process variables and other data using ProLink III .. process variables using the Field Communicator .. and acknowledge status alerts .. and acknowledge alerts using the display .. and acknowledge alerts using ProLink III .. alerts using the Field Communicator .. data in transmitter memory .. 118 Chapter 9 Measurement support .. the inline calibration check procedure .. the inline calibration check using ProLink III .. the inline calibration check using the Field Communicator .. the Known Density Verification procedure .. the Known Density Verification procedure using the display.

6 The Known Density Verification procedure using ProLink III .. the Known Density Verification procedure using theField Communicator .. Density measurement with Density Offset or Density Meter Density offset calibration .. Density offset calibration using the display .. Density offset calibration using ProLink III .. Density offset calibration using the Field Communicator .. temperature measurement with Temperature concentration measurement with Trim concentration measurement with Trim Slope and Trim up user-defined calculations .. used in user-defined calculations .. units used in user-defined calculations .. Density .. diagnostic input Density .. calculated diagnostic Density ..138 Chapter 10 Troubleshooting .. guide to troubleshooting .. power supply wiring .. grounding .. loop tests .. loop tests using the display .. loop tests using ProLink III.

7 Loop tests using the Field Communicator .. LED states .. alerts, causes, and recommendations .. measurement problems .. measurement problems .. insulation ..155 ContentsConfiguration and Use manual referral problems .. measurement problems .. measurement problems .. output problems .. output problems .. Period Signal (TPS) output problems .. sensor simulation for troubleshooting .. mA outputs .. mA outputs using ProLink III .. mA outputs using the Field Communicator .. HART communications .. Lower Range Value and Upper Range mA Output Fault for radio frequency interference (RFI) .. Flow the cutoffs .. for two-phase flow (slug flow) .. the drive gain .. or erratic drive gain .. drive gain data .. the pickoff voltage .. pickoff voltage data .. for internal electrical problems .. a device using the HART 7 Squawk feature .. 170 Appendices and referenceAppendix ACalibration certificate.

8 Calibration certificates ..171 Appendix BUsing the transmitter display .. of the transmitter interface .. the optical switches .. and use the display menu system .. a floating-point value using the display .. codes for process variables .. and abbreviations used in display menus .. 180 Appendix CUsing ProLink III with the transmitter .. information about ProLink III .. with ProLink III .. types supported by ProLink III .. with ProLink III over Modbus/RS-485 .. with ProLink III over HART/Bell 202 .. 198 Appendix DUsing the Field Communicator with the transmitter .. information about the Field Communicator .. with the Field Communicator .. 208 Appendix EConcentration measurement matrices, derived variables, and process variables .. matrices for the concentration measurement application .. measurement matrices available by order .. variables and calculated process variables.

9 214 ContentsivMicro Motion Compact Density Meters (CDM)Appendix FMID applications .. flow computer and power supply requirements .. computer Density calculations .. and external input connections to the flow computer .. support .. revision and checksum data .. the meter .. to unsecured mode ..224 ContentsConfiguration and Use manual vContentsviMicro Motion Compact Density Meters (CDM)Part IGetting StartedChapters covered in this part: Before you begin Quick startGetting StartedConfiguration and Use manual 1 Getting Started2 Micro Motion Compact Density Meters (CDM)1 Before you beginTopics covered in this chapter: About this manual Model codes and device types Communications tools and protocols Additional documentation and this manualThis manual provides information to help you configure, commission, use, maintain, andtroubleshoot the Micro Motion Compact Density Meter (CDM).

10 The following versions of the CDM are documented in this manual : Compact Density Meter with Analog Outputs Compact Density Meter with Analog Output and Discrete Output Compact Density Meter with Time Period Signal OutputFor the Compact Density Meter with FOUNDATION Fieldbus, see Micro Motion CompactDensity Meters with FOUNDATION Fieldbus: configuration and Use manual assumes that the following conditions apply: The meter has been installed correctly and completely, according to the instructions in theinstallation manual . The installation complies with all applicable safety requirements. The user is trained in all government and corporate safety codes and device typesYour device can be identified by the model code on the device codes and device typesTable 1-1: Model codeDevice nicknameI/OElectronics mount-ingCDM100M**CCDM mA Two mA outputs RS-485 terminalsIntegralCDM100M**DCDM DO One mA output One discrete output RS-485 terminalsIntegralBefore you beginConfiguration and Use manual 3 Model codes and device types (continued)Table 1-1: Model codeDevice nicknameI/OElectronics mount-ingCDM100M**BCDM TPS One mA output One Time Period Sig-nal output RS-485 terminalsIntegralCDM100M**ACDM FF FOUNDATION field-bus4-wire remotetransmitterRestrictionThe CDM mA, CDM DO, and CDM FF support a complete set of application and configurationoptions.