Example: air traffic controller

Molded case circuit breakers - Eaton

Volume 4 circuit ProtectionCA08100005E August 2017 case circuit BreakersSeries G circuit Overview ..V4-T2-2 Typical Applications ..V4-T2-2 Eaton Molded case circuit breakers in Assemblies .. G Globally Accepted breakers Product Overview ..V4-T2-4 Product Selection Overview ..V4-T2-6 Product Selection Guide ..V4-T2-7 Technical Data and Specifications ..V4-T2-9 Dimensions and Weights..V4-T2-14EG-Frame (15 125 Amperes) ..V4-T2-15JG-Frame (63 250 Amperes) ..V4-T2-29LG-Frame (250 630 Amperes)..V4-T2-47NG-Frame (320 1200 Amperes) ..V4-T2-65RG-Frame (800 2500 Amperes) ..V4-T2-74 Motor circuit Protectors (MCP).

programmable relays, making this the ultimate example of an intelligent node in a power distribution system Leverage the capabilities of this product to eliminate meters and other components from the system, making the power distribution system cost-effective and smaller, with increased intelligence and connectivity Each breaker frame section

Tags:

  Eaton, Intelligent, Case, Early, Circuit, Molded, Molded case circuit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Molded case circuit breakers - Eaton

1 Volume 4 circuit ProtectionCA08100005E August 2017 case circuit BreakersSeries G circuit Overview ..V4-T2-2 Typical Applications ..V4-T2-2 Eaton Molded case circuit breakers in Assemblies .. G Globally Accepted breakers Product Overview ..V4-T2-4 Product Selection Overview ..V4-T2-6 Product Selection Guide ..V4-T2-7 Technical Data and Specifications ..V4-T2-9 Dimensions and Weights..V4-T2-14EG-Frame (15 125 Amperes) ..V4-T2-15JG-Frame (63 250 Amperes) ..V4-T2-29LG-Frame (250 630 Amperes)..V4-T2-47NG-Frame (320 1200 Amperes) ..V4-T2-65RG-Frame (800 2500 Amperes) ..V4-T2-74 Motor circuit Protectors (MCP).

2 V4-T2-85 Motor Protector circuit breakers (MPCB) ..V4-T2-8930 mA Ground Fault (Earth Leakage) Module ..V4-T2-92 Current Limiting circuit Breaker Module ..V4-T2-96 High Instantaneous circuit Breaker for Selective Coordination ..V4-T2-101 Special Features and Accessories ..V4-T2-104 Motor Operators ..V4-T2-112 Plug-In Blocks ..V4-T2-114 Drawout Cassette .. C North American Standards and Special Application breakers Product Overview ..V4-T2-116 Standards and Certifications ..V4-T2-117 Quick Reference ..V4-T2-118G-Frame (15 100 Amperes) ..V4-T2-121F-Frame (10 225 Amperes) ..V4-T2-135J-Frame (70 250 Amperes).

3 V4-T2-153K-Frame (70 400 Amperes) ..V4-T2-161L-Frame (125 600 Amperes) ..V4-T2-185M-Frame (300 800 Amperes) ..V4-T2-211N-Frame (400 1200 Amperes)..V4-T2-222R-Frame (800 2500 Amperes)..V4-T2-237 Motor circuit Protectors (MCP) ..V4-T2-256 Motor Protection circuit breakers (MPCB) ..V4-T2-267 Type ELC Current Limiter Attachment (Size 0 4)..V4-T2-269 Current Limiting circuit Breaker Module ..V4-T2-270 Internal Accessories ..V4-T2-273 External Accessories .. PurposeOptimized Solution for HVAC/R and Pumping ApplicationsDefinite Purpose Molded case circuit breakers .. and CommunicationsPower Monitoring and Metering with Modbus RTUPM3 Monitoring and Metering Module.

4 BreakersEngine Generator circuit breakers ..V4-T2-343 Direct Current circuit breakers ..V4-T2-349 PVGard Solar circuit breakers ..V4-T2-363E2 Mining Service breakers ..V4-T2-372 Classic Mining breakers ..V4-T2-398 Add-On Ground Fault Protection Type GFR.. MechanismsHandle Mechanisms Series G ..V4-T2-415 Handle Mechanisms Series C ..V4-T2-427 LearnOnlineDrawingsOnlineV4-T2-2 Volume 4 circuit ProtectionCA08100005E August case circuit BreakersIntroductionSeries G E-Frame and Series C F-Frame Molded case circuit breakers ContentsDescriptionPageIntroductionSerie s G ..V4-T2-4 Series C.

5 V4-T2-116 Definite Purpose ..V4-T2-333PM3 Monitoring and Metering Module ..V4-T2-340 Specialty breakers ..V4-T2-343 LearnOnlineDrawingsOnlineProduct OverviewSeries G vs. Series C Eaton s Electrical Sector, under the Eaton brand, offers the widest variety of Molded case circuit breakers available today. Designed for electrical and machinery OEMs serving a range of industries and applications, these proven designs incorporate the latest in innovation with the high reliability that has been our hallmark since the advent of the circuit breaker in the Series C family ranges from 15 2500 amperes, and includes thermal-magnetic breakers , electronic trip breakers , Molded case switches, motor circuit protectors, and specially designed breakers for engine generator, DC and mining new Series G line features an average 35% size reduction, commonfield-installable internal accessories.

6 And advanced trip unit functionality that eliminates the need for rating plugs. These breakers meet the requirements of UL , CSA , IEC, CCC and CE, allowing the OEM to standardize on a design that meets the needs of their global customer DescriptionEaton Molded case circuit breakers cover the widest range of applications in the industry: Electrical OEMs Machinery OEMs Navy breakers : UL 489 Supplement SB MIL-C-17588 MIL-C-17361 ABS/NVR Mining breakers up to 110 0 Va c Earth leakage DC breakers 125 750 Vdc Engine generator breakers 15 1200 amperes Current limiting breakersTypical ApplicationsMachine Tool Control Panels and Motor Control CentersDesigned for these equipment requirements, including new world-class both main and branch circuit protection PillarsIn distribution systems to provide main and branch circuit distribution systems to provide main and branch circuit protection up to 2500 amperes (RG-Frame).

7 Busbar Trunking Tap-OffsIn busbar trunking tap-offs to provide circuit EnclosuresCompletely assembled in enclosures to meet specific customer ApplicationsSpecial versions of each Eaton frame are available to provide safe equipment control and protection in mining and other applications. Contact your Eaton agent or distributor for additional Eaton ApplicationsSwitchboardBusbar TrunkingTap-OffIndividual CircuitBreaker EnclosurePanelboardMachine ToolControl PanelVolume 4 circuit ProtectionCA08100005E August 2017 case circuit BreakersIntroductionEaton Molded case circuit breakers in AssembliesApplications Notes1125 amperes is the maximum UL and CSA rating for amperes is the maximum UL and CSA rating for amperes is the maximum UL and CSA rating for Control CentersFrameAmpere Range1A2A1A-LX 2A-LX 3A3E44B4D5 PPRL-C PRL-iPRL-C/iFreedomIT.

8 Enclosed ControlBus PlugsEnclosed BreakerSeries GEG15 160 1 JG20 250 LG100 630 2 NG400 1600 RG800 2500 3 Series CFD/ED15 225 JD70 250 KD70 400 LD400 600 MDL300 800 ND400 1200 RD800 2500 - V4-T2-4 Volume 4 circuit ProtectionCA08100005E August case circuit BreakersSeries GSeries G, 15 2500 Amperes for UL, CSA and IEC ApplicationsContentsDescriptionPageSerie s G Standards and Certifications.

9 V4-T2-5 Product Selection Overview ..V4-T2-6 Product Selection Guide ..V4-T2-7 Technical Data and Specifications ..V4-T2-9 Dimensions and Weights ..V4-T2-14EG-Frame (15 125 Amperes) ..V4-T2-15JG-Frame (63 250 Amperes) ..V4-T2-29LG-Frame (250 630 Amperes) ..V4-T2-47NG-Frame (320 1200 Amperes) ..V4-T2-65RG-Frame (800 2500 Amperes) ..V4-T2-74 Motor circuit Protectors (MCP) ..V4-T2-85 Motor Protector circuit breakers (MPCB) ..V4-T2-8930 mA Ground Fault (Earth Leakage) Module..V4-T2-92 Current Limiting circuit Breaker Module ..V4-T2-96 High Instantaneous circuit Breaker for Selective Coordination.

10 V4-T2-101 Special Features and Accessories ..V4-T2-104 Motor Operators ..V4-T2-112 Plug-In Blocks ..V4-T2-114 Drawout Cassette ..V4-T2-115 LearnOnlineDrawingsOnlineProduct OverviewSeries G, 15 2500 Amperes for UL, CSA and IEC Applications Eaton Series G Molded case circuit breakers provide increased performance in considerably less space than standard circuit breakers or comparable fusible G signifies global applications: Series G circuit breakers are marked with UL, CSA, CE, IEC and KEMA KEUR listings. Other advantages include: Field-fit accessories Common accessories through 630 amperes Electronic trip units from 20 to 2500 amperes UL-listed and IEC-rated, 30 mA ground fault/earth leakage modules Built-in ground fault protection down to 20 amperesThe EG, JG and LG frames are designed around space-saving footprints.


Related search queries