Motor Control Center Type Freedom Unitrol - Eaton

RP04304004 EFor more information visit: PROOF MCCTypeDatesCutler-Hammer Renewal PartsPublication F2100 Advantage E Series 2100 1995 1992 1987 95RP04304001 ERP04304002 ERP04304003E5 Star Freedom Unitrol F10 Unitrol 1975 871988 941972 89RP04304003 ERP04304004 ERP04304005E Type W9800 Unitrol11-3001965 751956 741935 65RP04304006 ERP04304007 ERP04304008E Motor Control Center Type Freedom Unitrol Renewal PartsSupersedes 1-28, dated September 2000 DescriptionPage Motor Control Center Type Freedom Unitrol Distributor Ordering Instructions .. 2 Procedure for Identifying MCC Renewal Units and Parts .. 2 Identifying Motor Control Center types .

For more information visit: www.cutler-hammer.eaton.com RP04304004E Renewal Parts Page 4 Effective: December 2002 Motor Control Center Type Freedom Unitrol

Tags:

  Center, Types, Control, Eaton, Motor, Freedom, Motor control center type freedom unitrol, Unitrol

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Motor Control Center Type Freedom Unitrol - Eaton

1 RP04304004 EFor more information visit: PROOF MCCTypeDatesCutler-Hammer Renewal PartsPublication F2100 Advantage E Series 2100 1995 1992 1987 95RP04304001 ERP04304002 ERP04304003E5 Star Freedom Unitrol F10 Unitrol 1975 871988 941972 89RP04304003 ERP04304004 ERP04304005E Type W9800 Unitrol11-3001965 751956 741935 65RP04304006 ERP04304007 ERP04304008E Motor Control Center Type Freedom Unitrol Renewal PartsSupersedes 1-28, dated September 2000 DescriptionPage Motor Control Center Type Freedom Unitrol Distributor Ordering Instructions .. 2 Procedure for Identifying MCC Renewal Units and Parts .. 2 Identifying Motor Control Center types .

2 3 Identification by Original Handle Mechanism .. 3 Procedure for Identifying Motor Control Center types .. 4 Freedom Unitrol Product Description .. 5 Replacement Starter Units .. 6 14 Unit Options .. 15 17 Structure Parts .. 18 22 Unit Parts .. 23 26 Replacement Feeder Units (All Vintages) .. 28F2100 AdvantageSeries 2100/5 StarFreedomUnitrolF10 UnitrolType W9800 Unitrol11-300 RP04304004 EFor more information visit: Renewal Parts Effective: December 2002 Page 3 Motor Control Center Type Freedom Unitrol PROOF Identifying Motor Control Center types In most cases, it is possible to identify MCC design by handle type.

3 Starter type, bucket width and door width can assist in identification. Table 1. Identifying Motor Control Center types 1 MCC types were sometimes produced outside the time spans shown. This was due to the overlap of production when a new design was adopted. 2 The unit wrappers are mechanically identical for these designs. 3 9800 originally was supplied with Rotary. New replacement units are manufactured with slider handle mechanism. Identification by Original Handle Mechanism MCCTypeType of HandleMechanismOriginal MCCS tarter TypeBucket WidthInches (mm)Door WidthInches (mm)OriginalManufacturer 1 Starter Type(Installed in New Unit) F2100 2 LeverFreedom Series 13-3/4 ( )15-5/8 ( )Cutler-Hammer 1994 to Present FreedomAdvantage 2 LeverAdvantage13-3/4 ( )15-5/8 ( )Westinghouse until 1994 Cutler-Hammer 1994 to PresentAdvantageSeries 2100 2 LeverA20013-3/4 ( )15-5/8 ( )Westinghouse until 1994 Cutler-Hammer 1994 to PresentA2005 Star 2 LeverA20013-3/4 ( )15-5/8 ( )Westinghouse 1975 1987A200 Freedom Unitrol SliderFreedom Series 13-7/8 ( )15-1/2 ( )

4 Cutler-Hammer 1988 1994 FreedomF10 UnitrolSlider and Lever Citation14 ( )14-3/4 ( ) w/ Wireway19-1/2 ( ) w/o WirewayCutler-Hammer 1972 1989 FreedomType WSliderA200 or 11-20011-3/4 ( )13-3/8 ( )Westinghouse 1965 1975A2009800 UnitrolRotary 3 3 Star/Citation16-1/8 ( )19-3/8 ( )Cutler-Hammer 1956 1974 Freedom11-300 Rotary11-200 Lifeline Type N/A20015-3/4 ( )20 ( )Westinghouse 1950 1965A200 Freedom UnitrolType W9800 Unitrol11-300 F2100, Advantage, Series 2100/5 StarF10 Unitrol Slider9800 UnitrolF10 Unitrol Lever and 9800 Unitrol For more information visit: Renewal Parts Page 4 Effective: December 2002 Motor Control Center Type Freedom Unitrol PROOF Procedure for Identifying Motor Control Center types In the event that the nameplate is missing, it is possible to identify the MCC design by the type of handle mechanism, starter type, bucket width and door width.

5 Table 2. Identifying Motor Control Center types F2100 Freedom Unitrol9800 UnitrolAdvantageF10 Unitrol11-300 Series 2100/5 StarType W MCC TypeType of Handle MechanismStarter TypeBucket WidthInches (mm)Door WidthInches (mm)Cutler-HammerRenewal PartsPublication F2100 Advantage Series 2100 LeverLeverLeverFreedom SeriesAdvantageA20013-3/4 ( )13-3/4 ( )13-3/4 ( )15-5/8 ( )15-5/8 ( )15-5/8 ( )RP04304001 ERP04304002 ERP04304003E5 StarFreedom Unitrol F10 UnitrolLeverSliderLever/SliderA200 Freedom SeriesCitation13-3/4 ( )13-7/8 ( )14 ( )15-5/8 ( )15-1/2 ( )14-3/4 ( ) w/ Wireway or19-1/2 ( ) w/o WirewayRP04304003 ERP04304004 ERP04304005 EType W 9800 Unitrol 11-300 SliderRotaryRotaryA200 or 11-2003 Star and/or Citation11-200 Life-line N and/or A20011-3/4 ( )16-1/8 ( )15-3/4 ( )13-3/8 ( )19-3/8 ( )20 ( )RP04304006E RP04304007 ERP04304008E RP04304004 EFor more information visit: Renewal Parts Effective: December 2002 Page 5 Motor Control Center Type Freedom Unitrol PROOF Freedom UnitrolProduct Description Introduced in 1989, this Cutler-Hammer MCC had vertical structures that measured 20 inches ( mm) wide, 91-1/2 inches ( mm) high and either 15 inches ( mm) or 20 inches ( mm) deep.

6 It allowed a 6-inch ( mm) size 1 unit 49 was applied to the units, structural framework, roof, side sheets, and all exterior Freedom Unitrol utilized the Freedom starter and was identified by the slider type handle mechanism. Bus and bus support systems were typically braced to withstand fault currents of 42,000A with the option to increase to 65,000A. Table 3. Freedom Unitrol Product Rating Maximum Ratings 3-Phase, 600V, 400 hp, 2500A BusFreedom UnitrolStructureFreedom Unitrol Starter Unit For more information visit: Renewal Parts Page 6 Effective: December 2002 Motor Control Center Type Freedom Unitrol PROOF Freedom Unitrol Replacement Starter Units How to Order When ordering a replacement unit, you receive: n Series C T HMCP.

7 N Freedom Starter. n Unit options as steel wrapper, door and handle the following steps for creating a catalog number for your specific application:Step 1 Select the correct replacement unit from Pages 6 14. When selecting, you need to know the following:nMCC of Unit (FVNR, FVR, Reduced Voltage Autotransformer or Part Winding or Solid State, FV 2 Speed, 1 Winding or 2 Speed, 2 Winding, etc.).nStarter size or horsepower device (breaker or fusible).nService 2 Verify required space is 3 Create a catalog number by selecting Catalog Codes from the columns per the example 4 Add modifications as required from the Unit Options on Pages 15 17.

8 Space available determines allowable 4. Catalog Numbering System ExampleTable 5. Full Voltage Non-Reversing Combination Starter HMCP (Must specify if HMCPE is required)1On 6-inch ( mm) units, the only options available are (3) E22 pilot devices and separate source fuse or disconnect or HorsepowerHMCP SizeCatalog CodeServiceVoltageCatalog CodeControlVoltageCatalog CodeSpace Options Inches (mm)Catalog Code208V240V380V480V600V1 1 3 1 3 1 2 5 10 1 3 10 3 10 3 7 15 30FD206 AFD206 BFD206 CFD206D208240380480575 BCDEF120208240380480575 ABCDEF 6 ( ) High12 ( ) High18 ( )

9 HighC 1SX210 15 25 25 25 50FD206E208240380480575 BCDEF120208240380480575 ABCDEF12 ( ) High18 ( ) HighSX325 30 50 50 50100FD206H208240380480575 BCDEF120208240380480575 ABCDEF18 ( ) High24 ( ) HighSX440 50 75100100150FD206L208240380480575 BCDEF120208240380480575 ABCDEF18 ( ) High24 ( ) HighSX56075 60100125150150200150200250400FD206 PFD206R208240380480575 BCDEF120208240380480575 ABCDEF48 ( ) HighSAdded OptionsUnit SizeC = CompactS = StandardX = OversizedControlVoltageA = 120VB = 208VC = 240VD = 380VE = 480VF = 575V Service VoltageB = 208VC = 240VD = 380VE = 480VF = 575VF D 2 0 6 C E A S C12 P10 P34 HMCP SizeSize, hp and AmperesRP04304004 EFor more information visit: PartsEffective: December 2002 Page 7 Motor Control Center Type Freedom UnitrolPROOFF reedom Unitrol Replacement Starter UnitsTable 6.

10 Full Voltage Reversing Combination Starter HMCP1 Full size bolt-in 7. Full Voltage 2 Speed 1 Winding Constant/Variable Torque HMCP 22 For constant horsepower instead of constant/variable torque, see Option SV6 on Page size bolt-in HorsepowerHMCP SizeCatalog CodeServiceVoltageCatalog CodeControlVoltageCatalog CodeSpace Options Inches (mm)Catalog Code208V240V380V480V600V1 1 3 1 3 1 2 5 10 1 3 10 3 10 3 7 15 30FD216 AFD216 BFD216 CFD216D208240380480575 BCDEF120208240380480575 ABCDEF18 ( ) High24 ( ) HighSX210 15 25 25 25 50FD216E208240380480575 BCDEF120208240380480575 ABCDEF18 ( ) High24 ( )


Related search queries