MXL Series - Fire Alarm Resources

SERVICE. MXL Series Pyrotronics Cerberus Division, Siemens SERVICE. MXL Control Panel n Advanced fire protection control panel z Multiplexed Alarm Reporting z custom Site Specific custom Programming n Basic Panel Contains: z Two Addressable Loop z Two NAC Circuits z Three System Relays ( Alarm , Trouble, Supervisory). n Additional MOM-4 Motherboard z Additional System Modules, Input or Control Outputs SERVICE. MXL Series n MXL. Basic Addressable System n MXLV. Addressable System with Integrated Voice Features n MXL-IQ. Standard MXL system with Limited Point Capacity n Network All of the above systems can be Integrated into a Network SERVICE.

SERVICE MXL Control Panel n Advanced fire protection control panel z Multiplexed Alarm Reporting z Custom Site Specific Custom Programming n Basic Panel Contains: z Two Addressable Loop z Two NAC Circuits z Three System Relays (Alarm, Trouble, Supervisory) n Additional MOM-4 Motherboard z Additional System Modules, Input or Control Outputs

Tags:

  Services, Custom, Service mxl

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MXL Series - Fire Alarm Resources

1 SERVICE. MXL Series Pyrotronics Cerberus Division, Siemens SERVICE. MXL Control Panel n Advanced fire protection control panel z Multiplexed Alarm Reporting z custom Site Specific custom Programming n Basic Panel Contains: z Two Addressable Loop z Two NAC Circuits z Three System Relays ( Alarm , Trouble, Supervisory). n Additional MOM-4 Motherboard z Additional System Modules, Input or Control Outputs SERVICE. MXL Series n MXL. Basic Addressable System n MXLV. Addressable System with Integrated Voice Features n MXL-IQ. Standard MXL system with Limited Point Capacity n Network All of the above systems can be Integrated into a Network SERVICE.

2 System Configuration Original Back Box Tan Alarm POWER. n MMB-1 Main Control Board PARTIAL. AUDIBLES. 2 Addressable Loops SYSTEM. z DISABLE. SUPERVISORY. TROUBLE NEXT HOLD. SECURITY. FCT. ALT 1. FCT. ALT 2. FCT. (120 Devices). 1 2 3 HELP F1. z 2 NAC Circuits ALT. 1. 4 5 6 PRINT F2. FORM. 7 8 9 FEED F3. ALT. ( Amps Each). 2. 0 ENTER CLEAR F4. TSP-40 n MOM-4 Motherboard z 4 Half Width Modules z 2 Full Width Modules MOM-4. z Capable of Holding 2. Addressable Modules y 2 Addressable Loops per Each Module (240 Devices Total). PSR-6/12. n TSP-40 Thermal Strip Printer SERVICE.

3 System Configuration Original Back Box Tan Alarm POWER. n MMB-1 Main Control Board PARTIAL. AUDIBLES. 2 Addressable Loops SYSTEM. z DISABLE. SUPERVISORY. TROUBLE NEXT HOLD. SECURITY. FCT. ALT 1. FCT. ALT 2. FCT. (120 Devices). 1 2 3 HELP F1. 2 NAC Circuits ALT. 4. 7. 5. 8. 6. 9. PRINT. FORM. FEED. 1. ALT. F2. F3. z ( Amps Each). 2. 0 ENTER CLEAR F4. MOM-4 n 2 MOM-4 Motherboards z 8 Half Width Modules MOM-4 z 4 Full Width Modules z Capable of Holding 2. Addressable Modules y 2 Addressable Loops per PSR-6/12 Each Module (480 Devices Total). SERVICE.

4 System Configuration Current Back Box Black Alarm POWER. n MMB-1/2 Main Control Board PARTIAL. AUDIBLES SYSTEM. DISABLE. SUPERVISORY. TROUBLE. SECURITY. NEXT HOLD. z 2 Addressable Loops (120 Devices). ALT 1 ALT 2. FCT FCT FCT. 1 2 3 HELP F1. ALT. 1. 4 5 6 PRINT F2. FORM. 7 8 9 FEED ALT F3. 2. z 2 NAC Circuits 0 ENTER CLEAR F4. ( Amps Each). n 2 MOM-4 Motherboards TSP-40. z 8 Half Width Modules MOM-4. MOM-4. z 4 Full Width Modules z Capable of Holding 2. Addressable Modules y 2 Addressable Loops per Each Module (480 Devices Total). PSR-6/12. n TSP-40 Thermal Strip Printer SERVICE.

5 System Configuration Current Back Box Black Alarm POWER. PARTIAL. n MMB-1/2 Main Control Board AUDIBLES SYSTEM. DISABLE. SUPERVISORY. TROUBLE. SECURITY. NEXT HOLD. z 2 Addressable Loops 1. 4. 2. 5. 3. 6. HELP. PRINT. ALT. 1. F1. F2. FCT. ALT 1. FCT. ALT 2. FCT. (120 Devices). FORM. 7 8 9 FEED ALT F3. 2. z 2 NAC Circuits 0 ENTER CLEAR F4. ( Amps Each). n 3 MOM-4 Motherboards 12 Half Width Modules MOM-4. MOM-4. MOM-4. z z 6 Full Width Modules z Capable of Holding 2. Addressable Modules y 2 Addressable Loops per Each Module (720 Devices PSR-6/12 Total).

6 SERVICE. MXL Control Panel n Continuous System Supervision z Microprocessor Based Polling n System Degrade Operation z Enhances system reliability in case of main CPU failure n System Outputs: z Programmable Output Operation z Cabinet Mounted Outputs z Addressable Filed Devices with Control Capability SERVICE. Basic System Components n MMB-1/2 Main System Board n MPS-6/12 System Power Supply n MKB-1 System Keyboard/Annunciator n TPS-40 Thermal Strip Printer n MBR-1 Back box n MDR-1 / MDR-1P Door Plain or with Printer View port n Batteries SERVICE.

7 MMB Main System Board n 16 - bit CPU with EPROM / RAM Memory Storage n Watchdog circuitry for CPU Operation n Flash memory for the CSG-M (System Specific Program). n Network Interface for Transponders or Peer-to-Peer Operation n Back-Up Battery Capability up to 60 Amp Hours n 24 VDC Regulator for Internal System Power Requirements z Field Power is Unfiltered with Minimal Rectification n AC Transfer Relay for Continuous Operation SERVICE. MMB Main System Board n Class A Power for CZM-1 Field Modules n 24 VDC unregulated supply n Two Analog Loops z Initiating and Control Devices on the Same Loop n Two Indicating Appliance Circuits z Class A or Class B Operation n Three Form C Relays z Alarm , Trouble and Supervisory SERVICE.

8 System Power Supplies n MPS-6 Power Supply z Supervised power supply z Amp, 24 VDC unregulated output n MPS-12 Power Supply z Supervised power supply z Amp, 24 VDC unregulated output z Transponder Power Supply SERVICE. MKB Keyboard/Annunciator 12 00 00 JAN 01 1990 SYSTEM. - - - CERBERUS PYROTRONICS SYSTEM MXL NORMAL. Alarm POWER. PARTIAL. AUDIBLES. SYSTEM. DISABLE. SUPERVISORY. TROUBLE NEXT HOLD. SECURITY. ALT 1 ALT 2. FCT FCT FCT. 1 2 3 HELP F1. ALT. 1. 4 5 6 PRINT F2. FORM. 7 8 9 FEED F3. ALT. 2. 0 ENTER CLEAR F4. SERVICE. MKB Keyboard/Annunciator n Annunciator and manual control panel for the MLX.

9 N 2 - line 80 character alphanumeric display n System Indicators: z Power indicator (Green). z Alarm indicator (Red). z Audibles silenced (Red). z Supervisory indicator (Yellow). z Trouble indicator (Yellow). z Security indicator (Yellow). z Point disabled (Yellow). SERVICE. MKB Keyboard/Annunciator n The Keypad contains the following keys: z ACKnowledge z AUD SIL (Audible Silence). z RESET. z NEXT display z HOLD display z Numeric keys z Cursor Controls z PRINT, HELP and CLEAR keys z User configurable function keys SERVICE. MKB Keyboard/Annunciator n MKB-1 - MXL Display/Keyboard This unit is used on the original version of the MXL system, GREY.

10 Backbox. The display mounts with stand off legs to bolts on the back of the main backbox. n MKB-2 - MXL Display/Keyboard Hinged This unit is used on the current version of the MXL system, BLACK. backbox. The display is hinged for wiring access n MKB-3 - MXL Display/Keyboard for 19" Rack Mounting This unit is used when the MXL system is installed in a Rack mount enclosure. For this configuration the MKB-RK Rack Mount Bracket must be used. n MKB-4 - MXL Display/Keyboard Hinged for IQ. This unit is used on the MXL-IQ system. The display is also used with the XL3 system upgrade kit to a MXL system configuration.