Example: bachelor of science

NI 6225 Device Specifications - National Instruments

Device Specifications . NI 6225. M Series Data Acquisition: 16 Bit, 250 kS/s, 80 AI, 2 AO, 24 DIO. The following Specifications are typical at 25 C, unless otherwise noted. For more information about the NI 6225, refer to the M Series User Manual available at manuals. Analog Input Number of channels 40 differential or 80 single ended ADC resolution 16 bits DNL No missing codes guaranteed INL Refer to the AI Absolute Accuracy section Sample rate Single channel maximum 250 kS/s Multichannel maximum (aggregate) 250 kS/s Minimum No minimum Timing accuracy 50 ppm of sample rate Timing resolution 50 ns Input coupling DC. Input range V, 1 V, 5 V, 10 V. Maximum working voltage for analog 11 V of AI GND.

DEVICE SPECIFICATIONS NI 6225 M Series Data Acquisition: 16 Bit, 250 kS/s, 80 AI, 2 AO, 24 DIO The following specifications are typical at 25 °C, unless otherwise noted.

Tags:

  Devices, Device specifications

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of NI 6225 Device Specifications - National Instruments

1 Device Specifications . NI 6225. M Series Data Acquisition: 16 Bit, 250 kS/s, 80 AI, 2 AO, 24 DIO. The following Specifications are typical at 25 C, unless otherwise noted. For more information about the NI 6225, refer to the M Series User Manual available at manuals. Analog Input Number of channels 40 differential or 80 single ended ADC resolution 16 bits DNL No missing codes guaranteed INL Refer to the AI Absolute Accuracy section Sample rate Single channel maximum 250 kS/s Multichannel maximum (aggregate) 250 kS/s Minimum No minimum Timing accuracy 50 ppm of sample rate Timing resolution 50 ns Input coupling DC. Input range V, 1 V, 5 V, 10 V. Maximum working voltage for analog 11 V of AI GND.

2 Inputs (signal + common mode). CMRR (DC to 60 Hz) 92 dB. Input impedance Device on AI+ to AI GND >10 G in parallel with 100 pF. AI- to AI GND >10 G in parallel with 100 pF. Device off AI+ to AI GND 820 . AI- to AI GND 820 . Input bias current 100 pA. Crosstalk (at 100 kHz). Adjacent channels -75 dB. Non-adjacent channels -90 dB1. Small signal bandwidth (-3 dB) 700 kHz Input FIFO size 4,095 samples Scan list memory 4,095 entries Data transfers PCI/PXI DMA (scatter-gather), interrupts, programmed I/O. USB USB Signal Stream, programmed I/O. Overvoltage protection for all analog input and sense channels Device on 25 V for up to two AI pins Device off 15 V for up to two AI pins Input current during overvoltage condition 20 mA maximum/AI pin Settling Time for Multichannel Measurements Accuracy, full-scale step, all ranges 90 ppm of step ( 6 LSB) 4 s convert interval 30 ppm of step ( 2 LSB) 5 s convert interval 15 ppm of step ( 1 LSB) 7 s convert interval 1 Channel AI < > crosstalk to channel AI < > is -71 dB.

3 This applies to channels with 64-channel separation. Example: AI (x) and AI (x + 64). 2 | | NI 6225 Device Specifications Typical Performance Graphs Figure 1. Settling Error versus Time for Different Source Impedances 10 k Error (ppm of Step Size). 1k 100. 100 . 1 k . 10 2 k . 5 k . 10 k . 1. 1 10 100. Time (ms). Figure 2. AI Small Signal Bandwidth 2. Normalized Signal Amplitude (dB). 0. 2. 4. 6. 8. 10. 12. 14. 1k 10 k 100 k 1000 k 10000 k Frequency (Hz). NI 6225 Device Specifications | National Instruments | 3. Figure 3. AI CMRR. 120. 100. CMRR (dB) 80. 60. 40. 10 V Range 5 V Range 20 1 V Range V Range 0. 10 100 1k 10 k 100 k Frequency (Hz). AI Absolute Accuracy Note Accuracies listed are valid for up to one year from the Device external calibration.

4 Table 1. AI Absolute Accuracy Nominal Nominal Residual Residual Absolute Range Range Gain Offset Offset Accuracy Positive Negative Error Error Tempco Random at Full Full Full (ppm of (ppm of (ppm of Noise, Scale Sensitivity Scale Scale Reading) Range) Range/ C) ( Vrms) ( V) ( V). 10 -10 75 20 57 244 3,100 5 -5 85 20 60 122 1,620 1 -1 95 25 79 30 360 135 80 175 13 112 Note Sensitivity is the smallest voltage change that can be detected. It is a function of noise. Gain tempco 25 ppm/ C. Reference tempco 5 ppm/ C. INL error 76 ppm of range 4 | | NI 6225 Device Specifications AI Absolute Accuracy Equation AbsoluteAccuracy = Reading (GainError) + Range (OffsetError) + NoiseUncertainty GainError = ResidualAIGainError + GainTempco (TempChangeFromLastInternalCal).

5 + ReferenceTempco (TempChangeFromLastExternalCal). OffsetError = ResidualAIOffsetError + OffsetTempco . (TempChangeFromLastInternalCal) + INLE rror Random Noise 3. NoiseUncertainty = for a coverage factor of 3 and averaging 100. 100 points. AI Absolute Accuracy Example Absolute accuracy at full scale on the analog input channels is determined using the following assumptions: TempChangeFromLastExternalCal = 10 C. TempChangeFromLastInternalCal = 1 C. number_of_readings = 100. CoverageFactor = 3 . For example, on the 10 V range, the absolute accuracy at full scale is as follows: GainError = 75 ppm + 25 ppm 1 + 5 ppm 10 = 150 ppm OffsetError = 20 ppm + 57 ppm 1 + 76 ppm = 153 ppm 244 3.

6 NoiseUncertainty = = 73 V. 100. AbsoluteAccuracy = 10 V (GainError) + 10 V (OffsetError) + NoiseUncertainty =. 3,100 V. Analog Output Number of channels 2. DAC resolution 16 bits DNL 1 LSB. Monotonicity 16 bit guaranteed Maximum update rate 1 channel 833 kS/s 2 channels 740 kS/s per channel Timing accuracy 50 ppm of sample rate Timing resolution 50 ns Output range 10 V. NI 6225 Device Specifications | National Instruments | 5. Output coupling DC. Output impedance . Output current drive 5 mA. Overdrive protection 25 V. Overdrive current 10 mA. Power-on state 20 mV. Power-off glitch 400 mV for 200 ms Output FIFO size 8,191 samples shared among channels used Data transfers Data transfers DMA (scatter-gather), interrupts, programmed I/O.

7 USB USB Signal Stream, programmed I/O. AO waveform modes Non-periodic waveform, periodic waveform regeneration mode from onboard FIFO, periodic waveform regeneration from host buffer including dynamic update Settling time, full-scale step, 6 s 15 ppm (1 LSB). Slew rate 15 V/ s Glitch energy Magnitude 100 mV. Duration s AO Absolute Accuracy Absolute accuracy at full-scale numbers is valid immediately following internal calibration and assumes the Device is operating within 10 C of the last external calibration. Note Accuracies listed are valid for up to one year from the Device external calibration. 6 | | NI 6225 Device Specifications Table 2. AO Absolute Accuracy Nominal Nominal Residual Residual Offset Absolute Range Range Gain Error Gain Offset Tempco Accuracy Positive Negative (ppm of Tempco Error (ppm (ppm of at Full Full Scale Full Scale Reading) (ppm/ C) of Range) Range/ C) Scale ( V).

8 10 -10 90 10 40 5 3,230. Reference tempco 5 ppm/ C. INL error 128 ppm of range AO Absolute Accuracy Equation AbsoluteAccuracy = OutputValue (GainError) + Range (OffsetError). GainError = ResidualGainError + GainTempco (TempChangeFromLastInternalCal) +. ReferenceTempco (TempChangeFromLastExternalCal). OffsetError = ResidualOffsetError + AOOffsetTempco . (TempChangeFromLastInternalCal) + INLE rror Digital I/O/PFI. Static Characteristics Number of channels 24 total, 8 (P0.< >), 16 (PFI < >/P1, PFI < >/P2). Ground reference D GND. Direction control Each terminal individually programmable as input or output Pull-down resistor 50 k typical, 20 k minimum Input voltage protection 20 V on up to two pins2.

9 Waveform Characteristics (Port 0 Only). Terminals used Port 0 (P0.< >). Port/sample size Up to 8 bits Waveform generation (DO) FIFO 2,047 samples Waveform acquisition (DI) FIFO 2,047 samples 2 Stresses beyond those listed under Input voltage protection may cause permanent damage to the Device . NI 6225 Device Specifications | National Instruments | 7. DI or DO Sample Clock frequency 0 MHz to 1 MHz, system and bus activity dependent Data transfers DMA (scatter-gather), interrupts, programmed I/O. DI or DO Sample Clock source3 Any PFI, RTSI, AI Sample or Convert Clock, Ctr n Internal Output, and many other signals PFI/Port 1/Port 2 Functionality Functionality Static digital input, static digital output, timing input, timing output Timing output sources Many AI, AO, counter, DI, DO timing signals Debounce filter settings 125 ns, s, ms, disable; high and low transitions; selectable per input Recommended Operating Conditions Level Minimum Maximum Input high voltage (VIH) V V.

10 Input low voltage (VIL) 0V V. Output high current (IOH) P0.< > -24 mA. Output high current (IOH) PFI < >/P1/P2 -16 mA. Output low current (IOL) P0.< > 24 mA. Output low current (IOL) PFI < >/P1/P2 16 mA. Electrical Characteristics Level Minimum Maximum Positive-going threshold (VT+) V. Negative-going threshold (VT-) V . Delta VT hystersis (VT+ - VT-) V . IIL input low current (Vin = 0 V) -10 A. IIH input high current (Vin = 5 V) 250 A. 3 The digital subsystem does not have its own dedicated internal timing engine. Therefore, a sample clock must be provided from another subsystem on the Device or an external source. 8 | | NI 6225 Device Specifications Digital I/O Characteristics Figure 4.