Example: biology

NI 9211 Datasheet

DATASHEETNI 9211 Datasheet4 TC, 80 mV, 24 Bit, 14 S/s Aggregate Screw-terminal connectivity 50 Hz/60 Hz noise rejection 250 Vrms, CAT II, channel-to- earth isolationThe NI 9211 thermocouple input module for use with CompactDAQ and NI CompactRIOchassis includes a 24-bit delta-sigma analog-to-digital converter, anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouplemeasurements. The NI 9211 features NIST-traceable calibration and a channel-to- earth grounddouble isolation barrier for safety, noise immunity, and high common-mode voltage ContentsAccessories NI 9211 NI 9211 Getting Started Guide NI 9932 Backshell Connector KitNI 9213NI 9214* For a J type thermocouple at 100 C using high-resolution mode when S/s/chScrew TerminalSpring TerminalIsothermal

Isolation options such as bank-to-bank, channel-to-channel, and channel-to-earth ground • -40 °C to 70 °C temperature range to meet a variety of application and environmental needs • Hot-swappable The majority of C Series modules are supported in …

Tags:

  Earth, Datasheet, Isolation, 1912, Ni 9211 datasheet, To earth

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of NI 9211 Datasheet

1 DATASHEETNI 9211 Datasheet4 TC, 80 mV, 24 Bit, 14 S/s Aggregate Screw-terminal connectivity 50 Hz/60 Hz noise rejection 250 Vrms, CAT II, channel-to- earth isolationThe NI 9211 thermocouple input module for use with CompactDAQ and NI CompactRIOchassis includes a 24-bit delta-sigma analog-to-digital converter, anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouplemeasurements. The NI 9211 features NIST-traceable calibration and a channel-to- earth grounddouble isolation barrier for safety, noise immunity.

2 And high common-mode voltage ContentsAccessories NI 9211 NI 9211 Getting Started Guide NI 9932 Backshell Connector KitNI 9213NI 9214* For a J type thermocouple at 100 C using high-resolution mode when S/s/chScrew TerminalSpring TerminalIsothermalTerminal BlockIsothermalTerminal Block250 VrmsCh-Earth250 VrmsCh-Ch250 VrmsCh-Earth250 VrmsCh-Earth14 S/s68 S/sIsolationContinuousConnectivitySample RateSoftwareSelectableOTD Autozero ProductNameNI 9211NI 9212 ChannelsMaximumAccuracy*( C) C SERIES THERMOCOUPLE MODULE COMPARISONNI C Series OverviewNI provides more than 100 C Series modules for measurement, control, and communicationapplications.

3 C Series modules can connect to any sensor or bus and allow for high-accuracymeasurements that meet the demands of advanced data acquisition and control applications. Measurement-specific signal conditioning that connects to an array of sensors and signals isolation options such as bank-to-bank, channel-to-channel, and channel-to- earth ground -40 C to 70 C temperature range to meet a variety of application and environmentalneeds Hot-swappableThe majority of C Series modules are supported in both CompactRIO and CompactDAQplatforms and you can move modules from one platform to the other with no | | NI 9211 DatasheetCompactRIOC ompactRIO combines an open-embedded architecturewith small size.

4 Extreme ruggedness, and C Seriesmodules in a platform powered by the NI LabVIEW reconfigurable I/O (RIO) architecture. Each systemcontains an FPGA for custom timing, triggering, andprocessing with a wide array of available modular I/O tomeet any embedded application is a portable, rugged data acquisition platformthat integrates connectivity, data acquisition, and signalconditioning into modular I/O for directly interfacing to anysensor or signal. Using CompactDAQ with LabVIEW, youcan easily customize how you acquire, analyze, visualize,and manage your measurement Professional Development System for Windows Use advanced software tools for large project development Generate code automatically using DAQ Assistant and InstrumentI/O Assistant Use advanced measurement analysis and digital signal processing Take advantage of open connectivity with DLLs, ActiveX,and.

5 NET objects Build DLLs, executables, and MSI installersNI LabVIEW FPGA Module Design FPGA applications for NI RIO hardware Program with the same graphical environment used for desktop andreal-time applications Execute control algorithms with loop rates up to 300 MHz Implement custom timing and triggering logic, digital protocols, andDSP algorithms Incorporate existing HDL code and third-party IP including Xilinx IPgenerator functions Purchase as part of the LabVIEW Embedded Control and MonitoringSuiteNI 9211 Datasheet | National Instruments | 3NI LabVIEW Real-Time Module Design deterministic real-time applications with LabVIEW graphical programming Download to dedicated NI or third-party hardware for reliableexecution and a wide selection of I/O Take advantage of built-in PID control, signal processing.

6 Andanalysis functions Automatically take advantage of multicore CPUs or setprocessor affinity manually Take advantage of real-time OS, development and debuggingsupport, and board support Purchase individually or as part of a LabVIEW suiteInput CircuitryThe NI 9211 channels share a common ground isolated from other modules in the channel passes through a filter and then a 24-bit analog-to-digital converter (ADC)samples the 1. Input Circuitry for One Channel of the NI 9211TC+TC COMNI 9211 InputImpedanceOpenThermocoupleDetectionC urrent FilteredDifferentialAmplifierIsolatedADC 10 M 10 M Open Thermocouple DetectionEach channel has an open thermocouple detection (OTD) circuit, which consists of a currentsource between the TC+ and TC- terminals.

7 If an open thermocouple is connected to thechannel, the current source forces a full-scale voltage across the ImpedanceEach channel has a resistor that produces an input impedance between the TC and COMterminals. The gain and offset errors resulting from the source impedance of connectedthermocouples are negligible for most applications. Thermocouples with a higher leadresistance can introduce more significant | | NI 9211 DatasheetThermocouple Measurement AccuracyThermocouple measurement errors depend partly on the following factors: the type of thermocouple the accuracy of the thermocouple the temperature that you are measuring the resistance of the thermocouple wires the cold-junction temperatureFor the best accuracy performance, set up the NI 9211 according to the getting started guide on to minimize thermal gradients across the NI 9211 AccuracyHeat dissipated by adjacent C Series modules or nearby heat sources can cause errors inthermocouple measurements by heating the NI 9211 terminals to a different temperature thanthe cold-junction compensation sensor.

8 Thermal gradient across the terminals can cause theterminals of different NI 9211 channels to be at different temperatures, which creates accuracyerrors and affects the relative accuracy between temperature measurement accuracy specifications include errors caused by the thermalgradient across the NI 9211 terminals for configurations with the NI 9211 terminals facingforward or ChannelThe NI 9211 has an internal autozero channel, which can be subtracted from eachthermocouple reading to compensate for offset errors. Use the autozero channel if the ambienttemperature is less than 15 C or more than 35 C.

9 Refer to the documentation for the softwarethat you are using for information about using the NI 9211 autozero 9211 SpecificationsThe following specifications are typical for the range -40 C to 70 C unless otherwise within typical use can vary based on chassis, mounting parameters, other modulespresent in the system, and installed The input terminals of this device are not protected for electromagneticinterference. As a result, this device may experience reduced measurement accuracyor other temporary performance degradation when connected cables are routed in anenvironment with radiated or conducted radio frequency electromagneticinterference.

10 To limit radiated emissions and to ensure that this device functionswithin specifications in its operational electromagnetic environment, takeprecautions when designing, selecting, and installing measurement probes 9211 Datasheet | National Instruments | 5 Input CharacteristicsNumber of channels4 thermocouple channels, 1 internal autozerochannel, 1 internal cold-junction compensationchannelADC resolution24 bitsType of ADCD elta-SigmaSampling modeScannedVoltage measurement range 80 mVTemperature measurement rangesWorks over temperature ranges defined byNIST (J, K, T, E, N, B, R, S thermocoupletypes)Conversion time70 ms per channel.


Related search queries