Example: marketing

NI 9401 Datasheet - National Instruments

DATASHEETNI 94018 DIO, 5 V/TTL, Bidirectional, 100 ns DSUB connectivity CompactDAQ counter compatibility 60 VDC, CAT I, channel-to-earth isolationThe NI 9401 is a bidirectional digital module for any NI CompactDAQ or CompactRIOchassis. The eight DIO channels are grouped in two ports that you can configureindependently for input or output. You can use the NI 9401 to implement custom digitalsystems such as counters/timers, digital communication protocols, pulse generation, ContentsAccessories NI 9401 NI 9401 Getting Started Guide Front- mount NI 9924 Screw-Terminal Block (781922-01) Cable DSUB Cable, 1 m (192568-01) DIN Rail Screw-Terminal Block (781081-01)EMC Compliance EMI Noise-Suppression Ferrite (782803-01) IsolationContinuousUpdateRateChannelsPro ductNameSignalLevelsC SERIES DIGITAL INPUT/OUTPUT MODULE COMPARISONC onnectivityDirectionNone1 sLVTTLNI 93814 DSUB Bidirectional100 ns5 V/TTL NI 94018 DSUBB idirectional 60 VDCCh-EarthNI 9402 LVTTL455 nsBNCB idirectionalNoneNI 94035 V/TTL 327 sDSUBB idirectional 60 VDCCh-EarthNI C Series OverviewNI provides more than 100 C Series modules for measurement, control, and communicationapplications.

chassis. The eight DIO channels are grouped in two ports that you can configure independently for input or output. You can use the NI 9401 to implement custom digital systems such as counters/timers, digital communication protocols, pulse generation, and beyond. Kit Contents Accessories • NI 9401 • NI 9401 Getting Started Guide Front-Mount

Tags:

  Mount, Chassis

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of NI 9401 Datasheet - National Instruments

1 DATASHEETNI 94018 DIO, 5 V/TTL, Bidirectional, 100 ns DSUB connectivity CompactDAQ counter compatibility 60 VDC, CAT I, channel-to-earth isolationThe NI 9401 is a bidirectional digital module for any NI CompactDAQ or CompactRIOchassis. The eight DIO channels are grouped in two ports that you can configureindependently for input or output. You can use the NI 9401 to implement custom digitalsystems such as counters/timers, digital communication protocols, pulse generation, ContentsAccessories NI 9401 NI 9401 Getting Started Guide Front- mount NI 9924 Screw-Terminal Block (781922-01) Cable DSUB Cable, 1 m (192568-01) DIN Rail Screw-Terminal Block (781081-01)EMC Compliance EMI Noise-Suppression Ferrite (782803-01) IsolationContinuousUpdateRateChannelsPro ductNameSignalLevelsC SERIES DIGITAL INPUT/OUTPUT MODULE COMPARISONC onnectivityDirectionNone1 sLVTTLNI 93814 DSUB Bidirectional100 ns5 V/TTL NI 94018 DSUBB idirectional 60 VDCCh-EarthNI 9402 LVTTL455 nsBNCB idirectionalNoneNI 94035 V/TTL 327 sDSUBB idirectional 60 VDCCh-EarthNI C Series OverviewNI provides more than 100 C Series modules for measurement, control, and communicationapplications.

2 C Series modules can connect to any sensor or bus and allow for high-accuracymeasurements that meet the demands of advanced data acquisition and control applications. Measurement-specific signal conditioning that connects to an array of sensors and signals Isolation options such as bank-to-bank, channel-to-channel, and channel-to-earth ground -40 C to 70 C temperature range to meet a variety of application and environmentalneeds Hot-swappableThe majority of C Series modules are supported in both CompactRIO and CompactDAQplatforms and you can move modules from one platform to the other with no combines an open-embedded architecturewith small size, extreme ruggedness, and C Seriesmodules in a platform powered by the NI LabVIEW reconfigurable I/O (RIO) architecture. Each systemcontains an FPGA for custom timing, triggering, andprocessing with a wide array of available modular I/O tomeet any embedded application | | NI 9401 DatasheetCompactDAQC ompactDAQ is a portable, rugged data acquisition platformthat integrates connectivity, data acquisition, and signalconditioning into modular I/O for directly interfacing to anysensor or signal.

3 Using CompactDAQ with LabVIEW, youcan easily customize how you acquire, analyze, visualize,and manage your measurement Professional Development System for Windows Use advanced software tools for large project development Generate code automatically using DAQ Assistant and InstrumentI/O Assistant Use advanced measurement analysis and digital signal processing Take advantage of open connectivity with DLLs, ActiveX,and .NET objects Build DLLs, executables, and MSI installersNI LabVIEW FPGA Module Design FPGA applications for NI RIO hardware Program with the same graphical environment used for desktop andreal-time applications Execute control algorithms with loop rates up to 300 MHz Implement custom timing and triggering logic, digital protocols, andDSP algorithms Incorporate existing HDL code and third-party IP including Xilinx IPgenerator functions Purchase as part of the LabVIEW Embedded Control and MonitoringSuiteNI 9401 Datasheet | National Instruments | 3NI LabVIEW Real-Time Module Design deterministic real-time applications with LabVIEW graphical programming Download to dedicated NI or third-party hardware for reliableexecution and a wide selection of I/O Take advantage of built-in PID control, signal processing.

4 Andanalysis functions Automatically take advantage of multicore CPUs or setprocessor affinity manually Take advantage of real-time OS, development and debuggingsupport, and board support Purchase individually or as part of a LabVIEW suiteInput/Output CircuitryThe eight DIO channels are internally referenced to COM, so you can use any of the nineCOM lines as a reference for the external 1. NI 9401 Input/Output CircuitryNI 9401 DIO3:0 DIO7:4 COMI solated BidirectionalBuffersProtectionIsolated BidirectionalBuffersProtectionNI 9401 SpecificationsThe following specifications are typical for the range -40 C to 70 C unless otherwise voltages are relative to COM unless otherwise Do not operate the NI 9401 in a manner not specified in this misuse can result in a hazard. You can compromise the safety protectionbuilt into the product if the product is damaged in any way. If the product isdamaged, return it to NI for CharacteristicsNumber of channels8 DIO channelsDefault power-on line directionInput4 | | NI 9401 DatasheetInput/output typeTTL, single-endedDigital logic V maximumHigh, VIH2 V minimumLow, V maximumOutput High, VOH ( V maximum)Sourcing 100 V minimumSourcing 2 V minimumOutput Low, VOLS inking 100 V maximumSinking 2 V maximumMaximum signal switching frequency, per channelInput8 input channels9 MHz4 input channels16 MHz2 input channels30 MHzOutput18 output channels5 MHz4 output channels10 MHz2 output channels20 MHzI/O propagation delay100 ns maximumI/O pulse width distortion10 nsInput current (0 V VIN V ) 250 AInput capacitance30 pFInput rise/fall time500 ns maximumOvervoltage protection, channel-to-COM2 30 V maximum on one channel at a timeMTBF1,244,763 hours at 25 C.

5 Bellcore Issue 2,Method 1, Case 3, Limited Part Stress Method1By number of output channels with an output load of 1 mA, 50 pF2 Continued use at this level will degrade the life of the 9401 Datasheet | National Instruments | 5 Power RequirementsPower consumption from chassisActive mode580 mW maximumSleep mode1 mW maximumThermal dissipation (at 70 C)Active mode580 mW maximumSleep mode1 mW maximumPhysical CharacteristicsIf you need to clean the module, wipe it with a dry For two-dimensional drawings and three-dimensional models of the C Seriesmodule and connectors, visit and search by module g ( oz)Safety VoltagesConnect only voltages that are within the following limits:Maximum voltage3 Channel-to-COM 30 V maximum on one channel at a time,Measurement Category IIsolation voltagesChannel-to-channelNoneChannel-to -earth groundContinuous60 VDC, Measurement Category IWithstand1,000 Vrms, verified by a 5 s dielectricwithstand testMeasurement Category I is for measurements performed on circuits not directly connected tothe electrical distribution system referred to as MAINS voltage.

6 MAINS is a hazardous liveelectrical supply system that powers equipment. This category is for measurements of voltagesfrom specially protected secondary circuits. Such voltage measurements include signal levels,special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and maximum voltage that can be applied or output between any channel and COM withoutdamaging the module or other | | NI 9401 DatasheetCaution Do not connect the NI 9401 to signals or use for measurements withinMeasurement Categories II, III, or Measurement Categories CAT I and CAT O are equivalent. These test andmeasurement circuits are not intended for direct connection to the MAINS buildinginstallations of Measurement Categories CAT II, CAT III, or CAT (UL)Class I, Division 2, Groups A, B, C, D, T4;Class I, Zone 2, AEx nA IIC T4 Canada (C-UL)Class I, Division 2, Groups A, B, C, D, T4;Class I, Zone 2, Ex nA IIC T4 Europe (ATEX) and International (IECEx)Ex nA IIC T4 GcSafety and Hazardous Locations StandardsThis product is designed to meet the requirements of the following electrical equipment safetystandards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 EN 60079-0:2012, EN 60079-15:2010 IEC 60079-0: Ed 6, IEC 60079-15; Ed 4 UL 60079-0; Ed 5, UL 60079-15.

7 Ed 3 CSA 60079-0:2011, CSA 60079-15:2012 Note For UL and other safety certifications, refer to the product label or the OnlineProduct Certification CompatibilityThis product meets the requirements of the following EMC standards for electrical equipmentfor measurement, control, and laboratory use: EN 61326 EMC requirements; Industrial Immunity EN 55011 (CISPR 11): Group 1, Class A emissions CE, C-Tick, ICES, and FCC Part 15 Emissions; Class ANote In the United States (per FCC 47 CFR), Class A equipment is intended foruse in commercial, light-industrial, and heavy-industrial locations. In Europe,Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intendedfor use only in heavy-industrial Group 1 equipment (per CISPR 11) is any industrial, scientific, or medicalequipment that does not intentionally generate radio frequency energy for thetreatment of material or inspection/analysis 9401 Datasheet | National Instruments | 7 Note For EMC declarations and certifications, and additional information, refer tothe Online Product Certification Compliance This product meets the essential requirements of applicable European Directives, as follows: 2014/35/EU; Low-Voltage Directive (safety) 2014/30/EU; Electromagnetic Compatibility Directive (EMC) 94/9/EC; Potentially Explosive Atmospheres (ATEX)Online Product CertificationRefer to the product Declaration of Conformity (DoC) for additional regulatory complianceinformation.

8 To obtain product certifications and the DoC for this product, visit , search by model number or product line, and click the appropriate link in theCertification and VibrationTo meet these specifications, you must panel mount the vibrationRandom (IEC 60068-2-64)5 grms, 10 Hz to 500 HzSinusoidal (IEC 60068-2-6)5 g, 10 Hz to 500 HzOperating shock (IEC 60068-2-27)30 g, 11 ms half sine; 50 g, 3 ms half sine;18 shocks at 6 orientationsEnvironmentalRefer to the manual for the chassis you are using for more information about meeting temperature(IEC 60068-2-1, IEC 60068-2-2)-40 C to 70 CStorage temperature(IEC 60068-2-1, IEC 60068-2-2)-40 C to 85 CIngress protectionIP40 Operating humidity (IEC 60068-2-78)10% RH to 90% RH, noncondensingStorage humidity (IEC 60068-2-78)5% RH to 95% RH, noncondensingPollution Degree2 Maximum altitude2,000 mIndoor use | | NI 9401 DatasheetEnvironmental ManagementNI is committed to designing and manufacturing products in an environmentally responsiblemanner.

9 NI recognizes that eliminating certain hazardous substances from our products isbeneficial to the environment and to NI additional environmental information, refer to the Minimize Our Environmental Impactweb page at This page contains the environmental regulations anddirectives with which NI complies, as well as other environmental information not included inthis Electrical and Electronic Equipment (WEEE)EU Customers At the end of the product life cycle, all NI products must bedisposed of according to local laws and regulations. For more information abouthow to recycle NI products in your region, visit RoHS National Instruments (RoHS) National Instruments RoHS (For information about China RoHScompliance, go to )NI 9401 Datasheet | National Instruments | 9 Refer to the NI Trademarks and Logo Guidelines at for information on NI trademarks. Other product andcompany names mentioned herein are trademarks or trade names of their respective companies.

10 For patents covering NIproducts/technology, refer to the appropriate location: Help Patents in your software, the file on your media, or theNational Instruments Patent Notice at You can find information about end-user license agreements (EULAs)and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and otherimport/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATIONCONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. Government Customers: The data contained inthis manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forthin FAR , DFAR , and DFAR 2015 National Instruments . All rights