Installation Guide AND Terminal BLOCK SPECIFICATIONSNI PXIe-4353 and TC-4353NI SC Express is a family of PXI Express modules with integrated data acquisition and signal conditioning. These devices offer increased speed, accuracy, and synchronization features that are well suited for high-density sensor measurement and signal-conditioning systems. The TC-4353 rack-mount Terminal block accessories provides thermocouple plug-in Terminal Guide describes how to install and configure the NI PXIe-4353 module and TC-4353 Terminal block, thermocouple connector signals, and verify that the system is working properly. Current versions of NI documents are available at NI PXIe-4353 is a high-accuracy thermocouple input module that supports up to 32 thermocouple inputs and has 8 cold-junction compensation (CJC) channels for improved CJC accuracy.

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4353 and TC-4353 NI SC Express is a family of PXI Express modules with integrated data acquisition and signal

Tags:

  3345, Ipex, Ni pxie 4353

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of NI PXIe-4353 and TC-4353 Installation Guide and Terminal ...

1 Installation Guide AND Terminal BLOCK SPECIFICATIONSNI PXIe-4353 and TC-4353NI SC Express is a family of PXI Express modules with integrated data acquisition and signal conditioning. These devices offer increased speed, accuracy, and synchronization features that are well suited for high-density sensor measurement and signal-conditioning systems. The TC-4353 rack-mount Terminal block accessories provides thermocouple plug-in Terminal Guide describes how to install and configure the NI PXIe-4353 module and TC-4353 Terminal block, thermocouple connector signals, and verify that the system is working properly. Current versions of NI documents are available at NI PXIe-4353 is a high-accuracy thermocouple input module that supports up to 32 thermocouple inputs and has 8 cold-junction compensation (CJC) channels for improved CJC accuracy.

2 The TC-4353 Terminal block has eight thermistors that provide CJC for TC-4353 Terminal block is designed for use with the following module as specified:NI PXIe-4353 .. 80 mV maximum voltage measurement rangeCautionDo not supply hazardous voltages (>30 Vpk/60 VDC) to the TC-4353 Terminal to the NI PXIe-4353 Specifications document for additional voltage and safety keying of this Terminal block prevents it from connecting to other modules that could be damaged by the voltage present on the Terminal block. However, you should only use this Terminal block with its supported | |NI PXIe-4353 and TC-4353 ContentsWhat You Need to Get Started.

3 3 Installation .. 3 Step 1. Install the Software .. 3 Step 2. Unpack and Install the Module .. 4 Step 3. Install the Terminal Block, Chassis, and Cables .. 5 Step 4. Confirm NI SC Express Module Recognition .. 9 Step 5. Run Test Panels .. 10 Step 6. Take an NI-DAQmx Measurement .. 10NI-DAQmx Channels and Tasks .. 10 Configure a Task Using the DAQ Assistant from 10 Step 7. Use Your NI SC Express 4353 in an Application .. 11 Programming 11 Removal .. 12 Step 1. Remove the Terminal Block and Cables .. 12 Step 2. Remove the 12 Create a Simulated 13 Cold-Junction 14 Minimizing Thermal Gradients .. 15 Calibrate the Module and Terminal Block.

4 15 More 16 Troubleshooting ..16 Specifications .. 16 Calibration .. 16 Electrical .. 16 Mechanical .. 18 Physical .. 18 Environmental Specifications .. 18 Operating 18 Storage Environment .. 19 Shock and Vibration .. 19 Safety Voltages ..19 Safety Standards ..20 Electromagnetic Compatibility .. 20CE Compliance .. 20 Online Product Certification .. 21 Environmental Management .. 21 Worldwide Technical Support .. 21NI PXIe-4353 and TC-4353 | National Instruments|3 What You Need to Get StartedTo set up and use the TC-4353 rack-mount Terminal block with the NI PXIe-4353 module, you need the following items: Hardware TC-4353 rack-mount Terminal block NI PXIe-4353 module PXIechassis 19 in.

5 Rack to accommodate the TC-4353 and NI PXIe-4353 Four 10-32 screws of a length suitable for your application (not supplied by NI) SH96-96-1 cable and included standoffs Rack-mount kit (as required for your application) Shielded thermocouple wire and thermocouple miniconnectors as required for your application Tools Phillips-head and flathead screwdrivers as required by your application Wire cutter Wire insulation stripper Documentation NI PXIe-4353 and TC-4353 Installation Guide and Terminal Block Specifications Read Me First: Safety and Electromagnetic Compatibility NI PXIe-4353 User Manual PXIe chassis user manualYou can download needed documents from 1.

6 Install the SoftwareNoteYou must be an administrator to install NI software and devices on your installing the NI SC Express hardware, make sure the following are installed in the order application software, such as LabVIEW, LabWindows /CVI , or . or | |NI PXIe-4353 and TC-4353 NoteWhen installing NI application software, such as NI LabVIEW, refer to the NI-DAQmx Readme on the software disc for supported software versions. Back up any applications before upgrading software or modifying the an NI-DAQmx simulated device, you can test NI-DAQmx applications without installing hardware. Refer to the Create a Simulated Device section for instructions for creating NI-DAQmx simulated 2.

7 Unpack and Install the ModuleRemove the packaging and inspect the module. Contact NI if the module is damaged. Do not install a damaged module is static sensitive. Always properly ground yourself and the equipment when handling or connecting to the the following steps to install the NI SC Express module while referring to Figures 1 and 2 off the PXI Express chassis. Refer to the chassis manual for chassis Installation and configuration to the Read Me First: Safety and Electromagnetic Compatibility, included with your module, before connecting or disconnecting signal a supported PXI Express slot in the chassis. NI SC Express devices can be placed only in PXI Express Peripheral slots, PXI Express Hybrid Peripheral slots, and PXI Express System Timing slots.

8 Refer to the chassis documentation for 1. Symbols for PXI Express/PXI Express Hybrid/PXI the filler panel and touch any metal part of the chassis to discharge static the module edges into the module guides at the top and bottom of the installing the module, make sure both edges are positioned inside the guides and that the module components do not come into contact with adjacent PXI Express System Controller Slot2 PXI Peripheral Slot3 PXI Express Hybrid Peripheral Slot4 PXI Express System Timing SlotNI PXIe-1062Q1234NI PXIe-4353 and TC-4353 | National Instruments| the module along the guides until it reaches the rear connector.

9 Then seat the module by pushing the front panel until it is flush with the front panel of the the module to the chassis using the front-panel captive screws, shown in Figure 2. Tighten the screws to N m ( lb in.).Figure 2. Installing NI SC Express ModulesStep 3. Install the Terminal Block, Chassis, and CablesCautionRefer to the Read Me First: Safety and Electromagnetic Compatibility document before removing equipment covers or connecting or disconnecting any signal not supply hazardous voltages (>30 Vpk/60 VDC) to the Terminal chassis can be powered on or off when installing the Terminal ensure the EMC performance specified for the connected NI PXIe-4353 module, operate this product only with shielded thermocouple install the rack-mount Terminal block into the rack, complete the following steps while referring to Figure the TC-4353 in the desired position by installing and tightening the four rack-mounting ScrewsNI PXIe-1062 QCOOLING CLEARANCE AND FAN FILTER MAINTENANCE REQUIRED.

10 SEE CLEARANCE AND FAN FILTER MAINTENANCE REQUIRED. SEE | |NI PXIe-4353 and TC-4353If the chassis is not already installed in the rack, complete the following the PXIe chassis rack-mount hardware to the NI PXIe chassis according to the rack-mount hardware the PXIe chassis in the rack in the desired 3. TC-4353 Installation and Front Connections1 Rack-Mounting Screws (4)2To Thermocouple Sensors3 Thermocouple Miniconnector4 Thermocouple Miniconnector Receptacle5 Shield Drain Wire6 Chassis Ground Screw7TC-4353 Rack-Mount Terminal Block8 COM Terminals9To COMNATIONALINSTRMUENTSTC0TC1TC2TC3TC4TC5 TC6TC7TC8TC9TC10TC11TC12TC13TC14TC15TC16 TC17TC18TC19TC20TC21TC22TC23TC24TC25TC26 TC27TC28TC29TC30TC31 COM10TC-4353 32 Ch Thermocouple Accessory60V!