Example: quiz answers

OPERATION INSTALLATION - Fire Alarm Resources

fire Safety INSTALLATION Instructions Model CMI-300. CXL/MXL Interface Module NCCNT WAN/MXL Interface Module OPERATION INSTALLATION . CXL/MXL INTERFACE MODULE 1. Remove the battery connections and the AC power The SIEMENS Model CMI-300 provides modem connections from the MXL System. (Refer to the communications between an MXL System and a MXL MANUAL, P/N 315-092036.). CXL System. The CMI-300 module is located on the 2. Check that there is a jumper installed for jumper J2, MOM-4 board in the MXL enclosure. The CMI-300 pins 1 and 2 on the CMI-300 module. (See Figure 1.). plugs into a half slot in the MOM-4. It translates 3. Set the CMI-300 network communication address by signals from the MXL communication lines of the using the dipswitch settings on switch SW1 (See MMB-1/-2 to CXL modem signals. This signal is then Table 1). transmitted along suitable cable to the CXM-1. module in the CXL enclosure.

˘ˇ OPERATION The Model CMI-300 provides modem communications between an MXL System and a CXL System. The CMI-300 module is located on the

Tags:

  Operations, Fire

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of OPERATION INSTALLATION - Fire Alarm Resources

1 fire Safety INSTALLATION Instructions Model CMI-300. CXL/MXL Interface Module NCCNT WAN/MXL Interface Module OPERATION INSTALLATION . CXL/MXL INTERFACE MODULE 1. Remove the battery connections and the AC power The SIEMENS Model CMI-300 provides modem connections from the MXL System. (Refer to the communications between an MXL System and a MXL MANUAL, P/N 315-092036.). CXL System. The CMI-300 module is located on the 2. Check that there is a jumper installed for jumper J2, MOM-4 board in the MXL enclosure. The CMI-300 pins 1 and 2 on the CMI-300 module. (See Figure 1.). plugs into a half slot in the MOM-4. It translates 3. Set the CMI-300 network communication address by signals from the MXL communication lines of the using the dipswitch settings on switch SW1 (See MMB-1/-2 to CXL modem signals. This signal is then Table 1). transmitted along suitable cable to the CXM-1. module in the CXL enclosure.

2 4. Plug the CMI-300 module in the MOM-4 optional module card cage. (For CXL applications refer to the CXL SYSTEM 5. Connect the wiring from the CMI-300 to a modem OPERATION , INSTALLATION , AND MAINTE- port on the CXM-1 module by following Figure 2, 3, NANCE MANUAL, P/N 315-085683 and the CXL or 4, as applicable. WIRING DIAGRAM, P/N 315-086208.) [Refer to the CXM-1 Instructions (P/N 315-086211). for the dipswitch settings for the modem port.]. NCCNT WAN/MXL INTERFACE MODULE OR. The SIEMENS Model CMI-300 provides modem Connect the wiring from the CMI-300 to a modem communications between an MXL System and an port on the HUB-4 module by following Figures 5 or NCCNT WAN System. The CMI-300 module is located 6 as applicable. on the MOM-4 board in the MXL enclosure. The CMI- 300 plugs into a half slot in the MOM-4. It translates [Refer to the HUB-4 Instructions (P/N 315-099302).]. signals from the MXL communication lines of the 6.

3 Re-apply AC power to the MXL System; then MMB-1/-2 to CXL modem signals. This signal is then connect the batteries to the system. transmitted along suitable cable to the HUB-4 module in the COM-1 enclosure. OPERATIONAL TEST AND. (For NCCNT WAN applications refer to the NCCNT. WAN APPENDIX, P/N 315-099318.) TROUBLESHOOTING. ELECTRICAL RATING When an initiating device is activated and the MXL. responds, but the CXL or NCCNT WAN panel fails to Supervisory or Alarm module: respond, follow the steps below. 5 VDC, 96mA max 24 VDC, 30mA max 1. Check the dipswitch address settings on the CMI-300. Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview Boulevard Florham Park, New Jersey 07932 Brampton, Ontario L6T 5E4. P/N 315-091259-7. 2. Check the XMIT LED (DS2) on the CMI-300 5. If the problem persists, replace the CMI-300. module for activity approximately every 20 module, reset the dipswitch address settings, and seconds (the LED indicates MXL network retest the unit.)

4 Communication transmission). If none of the steps above solves the problem, refer 3. Check for proper field wiring connections between to the MXL MANUAL, P/N 315-092036. the CMI-300 and the CXM-1 or HUB-4 module, and check that the CXL or NCCNT WAN System MODULE PROGRAMMING. is powered. Refer to the CSG-M MANUAL, P/N 315-090381, for 4. Move the CMI-300 wiring to another port on the further instructions on configuring the MXL Control CXM-1 or HUB-4 and check for communications. Panel. Figure 1. INSTALLATION TYPICAL CLASS B (STYLE 4). CONNECTION. MOM-4. TB1. TB1. 1 2 3 4 1 2 3 4 1 2 3 4. 2-WIRE. 18 AWG. CABLE MIN* LLM-1 LLM-1. TB2. TB2. 1 2 3 4 1 2 3 4. 1 2 3 4. * USE 2-WIRE COPPER CABLE, 105 C, 300V, 18 AWG, CXM-1. SOLID OR STRANDED, MAX 7 STRANDS. Notes: 1. All wiring must conform to local codes and to the authority having jurisdiction over the INSTALLATION . 2. All circuits are rated 2 volts peak to peak, All circuits are supervised.

5 3. Operates in full conformance with Style 4. Figure 2. Typical Class B (Style 4) Wiring Connection 2. TYPICAL STYLE 7. CONNECTION. MOM-4. TB1. TB1. 1 2 3 4 1 2 3 4 1 2 3 4. LLM-1 LLM-1. *USE 2-WIRE. TB2. TB2. 1 2 3 4 1 2 3 4 COPPER CABLE, 105 C, 300V, 18 AWG, SOLID OR STRANDED, MAX 7 STRANDS. TWO 2-WIRE 18 AWG CABLE MIN*. 600 OHM MAX LINE RESISTANCE. TOTAL PER PAIR. TB1. TB1. 1 2 3 4 1 2 3 4. LLM-1 LLM-1. TB2. TB2. 1 2 3 4 1 2 3 4. 1 2 3 4. CXM-1. Notes: 1. All wiring must conform to local codes and to the authority having jurisdiction over the INSTALLATION . 2. All circuits are rated 2 volts peak to peak, All circuits are supervised. 3. Operates in full conformance with Style 7. Figure 3. Typical Style 7 Connection CONDITIONED NON-SWITCHED. LEASED TELEPHONE LINE, 600 OHMS IMPEDANCE. TYPICAL CLASS B (STYLE 4). CONNECTION. MOM-4. TB1. TB1. 1 2 3 4 1 2 3 4 1 2 3 4. R1 LLM-1 LLM-1. 560 OHMS, TB2. TB2.

6 1/2W, 5% 1 2 3 4 1 2 3 4. P/N 140-820366. R2. 1 2 3 4. CXM-1. Notes: 1. All wiring must conform to local codes and to the authority having jurisdiction over the INSTALLATION . 2. All circuits are rated 2 volts peak to peak, All circuits are supervised. 3. Operates in full conformance with Style 4. Figure 4. Typical Class B (Style 4) Connection Using Conditioned, Non-Switched Telephone Line 3. TYPICAL CLASS B (STYLE 4). CONNECTION. MOM-4 MODEM 2. TB1. 1 2 3 4 1 2 3 4. - - +. +. 2-WIRE. 18 AWG A B B A. CABLE MIN* LLM-1. - - TB2. 1 2 3 4. +. +. 1 2 3 4 5 6 7 8. 9 10 11 12 13 14 15 16. A B B A A B B A. * USE 2-WIRE COPPER CABLE, 105 C, 300V, 18 AWG, SOLID OR STRANDED, MAX 7 STRANDS. - - - - +. +. +. +. MODEM 3 MODEM 4. ONE SLOT OF CC-5 WITH HUB-4 INSTALLED. 17 18 19 20 21 22 23 24. Figure 5. Typical Class B (Style 4) Wiring Connection With HUB-4. TYPICAL STYLE 7. CONNECTION. MOM-4. TWO 2-WIRE 18 AWG CABLE MIN*.

7 TB1. 1 2 3 4 1 2 3 4 600 OHM MAX LINE RESISTANCE. TOTAL PER PAIR. MODEM 2. LLM-1. - - +. +. TB2. 1 2 3 4. A B B A. - - +. +. 1 2 3 4 5 6 7 8. 9 10 11 12 13 14 15 16. A B B A A B B A. TB1. 1 2 3 4. - - - - +. +. +. +. LLM-1. MODEM 3 MODEM 4. TB2. 1 2 3 4. ONE SLOT OF CC-5 WITH HUB-4 INSTALLED. *USE 2-WIRE 17 18 19 20 21 22 23 24. COPPER CABLE, 105 C, 300V, 18 AWG, SOLID OR STRANDED, MAX 7 STRANDS. Figure 6. Typical Style 7 Wiring Connection With HUB-4. 4. TABLE 1. NETWORK ADDRESS PROGRAMMING. ADDR 87654321 ADDR 87654321 ADDR 87654321 ADDR 87654321. 000 ILLEGAL 064 OXOOOOOO 128 XOOOOOOO 192 XXOOOOOO. 001 ILLEGAL 065 OXOOOOOX 129 XOOOOOOX 193 XXOOOOOX. 002 ILLEGAL 066 OXOOOOXO 130 XOOOOOXO 194 XXOOOOXO. 003 OOOOOOXX 067 OXOOOOXX 131 XOOOOOXX 195 XXOOOOXX. 004 OOOOOXOO 068 OXOOOXOO 132 XOOOOXOO 196 XXOOOXOO. 005 OOOOOXOX 069 OXOOOXOX 133 XOOOOXOX 197 XXOOOXOX. 006 OOOOOXXO 070 OXOOOXXO 134 XOOOOXXO 198 XXOOOXXO.

8 007 OOOOOXXX 071 OXOOOXXX 135 XOOOOXXX 199 XXOOOXXX. 008 OOOOXOOO 072 OXOOXOOO 136 XOOOXOOO 200 XXOOXOOO. 009 OOOOXOOX 073 OXOOXOOX 137 XOOOXOOX 201 XXOOXOOX. 010 OOOOXOXO 074 OXOOXOXO 138 XOOOXOXO 202 XXOOXOXO. 011 OOOOXOXX 075 OXOOXOXX 139 XOOOXOXX 203 XXOOXOXX. 012 OOOOXXOO 076 OXOOXXOO 140 XOOOXXOO 204 XXOOXXOO. 013 OOOOXXOX 077 OXOOXXOX 141 XOOOXXOX 205 XXOOXXOX. 014 OOOOXXXO 078 OXOOXXXO 142 XOOOXXXO 206 XXOOXXXO. 015 OOOOXXXX 079 OXOOXXXX 143 XOOOXXXX 207 XXOOXXXX. 016 OOOXOOOO 080 OXOXOOOO 144 XOOXOOOO 208 XXOXOOOO. 017 OOOXOOOX 081 OXOXOOOX 145 XOOXOOOX 209 XXOXOOOX. 018 OOOXOOXO 082 OXOXOOXO 146 XOOXOOXO 210 XXOXOOXO. 019 OOOXOOXX 083 OXOXOOXX 147 XOOXOOXX 211 XXOXOOXX. 020 OOOXOXOO 084 OXOXOXOO 148 XOOXOXOO 212 XXOXOXOO. 021 OOOXOXOX 085 OXOXOXOX 149 XOOXOXOX 213 XXOXOXOX. 022 OOOXOXXO 086 OXOXOXXO 150 XOOXOXXO 214 XXOXOXXO. 023 OOOXOXXX 087 OXOXOXXX 151 XOOXOXXX 215 XXOXOXXX. 024 OOOXXOOO 088 OXOXXOOO 152 XOOXXOOO 216 XXOXXOOO.

9 025 OOOXXOOX 089 OXOXXOOX 153 XOOXXOOX 217 XXOXXOOX. 026 OOOXXOXO 090 OXOXXOXO 154 XOOXXOXO 218 XXOXXOXO. 027 OOOXXOXX 091 OXOXXOXX 155 XOOXXOXX 219 XXOXXOXX. 028 OOOXXXOO 092 OXOXXXOO 156 XOOXXXOO 220 XXOXXXOO. 029 OOOXXXOX 093 OXOXXXOX 157 XOOXXXOX 221 XXOXXXOX. 030 OOOXXXXO 094 OXOXXXXO 158 XOOXXXXO 222 XXOXXXXO. 031 OOOXXXXX 095 OXOXXXXX 159 XOOXXXXX 223 XXOXXXXX. 032 OOXOOOOO 096 OXXOOOOO 160 XOXOOOOO 224 XXXOOOOO. 033 OOXOOOOX 097 OXXOOOOX 161 XOXOOOOX 225 XXXOOOOX. 034 OOXOOOXO 098 OXXOOOXO 162 XOXOOOXO 226 XXXOOOXO. 035 OOXOOOXX 099 OXXOOOXX 163 XOXOOOXX 227 XXXOOOXX. 036 OOXOOXOO 100 OXXOOXOO 164 XOXOOXOO 228 XXXOOXOO. 037 OOXOOXOX 101 OXXOOXOX 165 XOXOOXOX 229 XXXOOXOX. 038 OOXOOXXO 102 OXXOOXXO 166 XOXOOXXO 230 XXXOOXXO. 039 OOXOOXXX 103 OXXOOXXX 167 XOXOOXXX 231 XXXOOXXX. 040 OOXOXOOO 104 OXXOXOOO 168 XOXOXOOO 232 XXXOXOOO. 041 OOXOXOOX 105 OXXOXOOX 169 XOXOXOOX 233 XXXOXOOX. 042 OOXOXOXO 106 OXXOXOXO 170 XOXOXOXO 234 XXXOXOXO.

10 043 OOXOXOXX 107 OXXOXOXX 171 XOXOXOXX 235 XXXOXOXX. 044 OOXOXXOO 108 OXXOXXOO 172 XOXOXXOO 236 XXXOXXOO. 045 OOXOXXOX 109 OXXOXXOX 173 XOXOXXOX 237 XXXOXXOX. 046 OOXOXXXO 110 OXXOXXXO 174 XOXOXXXO 238 XXXOXXXO. 047 OOXOXXXX 111 OXXOXXXX 175 XOXOXXXX 239 XXXOXXXX. 048 OOXXOOOO 112 OXXXOOOO 176 XOXXOOOO 240 XXXXOOOO. 049 OOXXOOOX 113 OXXXOOOX 177 XOXXOOOX 241 XXXXOOOX. 050 OOXXOOXO 114 OXXXOOXO 178 XOXXOOXO 242 XXXXOOXO. 051 OOXXOOXX 115 OXXXOOXX 179 XOXXOOXX 243 XXXXOOXX. 052 OOXXOXOO 116 OXXXOXOO 180 XOXXOXOO 244 XXXXOXOO. 053 OOXXOXOX 117 OXXXOXOX 181 XOXXOXOX 245 XXXXOXOX. 054 OOXXOXXO 118 OXXXOXXO 182 XOXXOXXO 246 XXXXOXXO. 055 OOXXOXXX 119 OXXXOXXX 183 XOXXOXXX 247 XXXXOXXX. 056 OOXXXOOO 120 OXXXXOOO 184 XOXXXOOO 248 ILLEGAL. 057 OOXXXOOX 121 OXXXXOOX 185 XOXXXOOX 249 ILLEGAL. 058 OOXXXOXO 122 OXXXXOXO 186 XOXXXOXO 250 ILLEGAL. 059 OOXXXOXX 123 OXXXXOXX 187 XOXXXOXX 251 ILLEGAL. 060 OOXXXXOO 124 OXXXXXOO 188 XOXXXXOO 252 ILLEGAL.