Example: quiz answers

Owners Manual TIME - LED Andon

The Trimline Series Timer with Light Block Owners Manual (Firmware PP-2110-382A). TIME. American LED-gible Inc. 1776 Lone Eagle St. Columbus, OH 43228. (614) 851-1100 Phone (614) 851-1121 Fax www PB-2149-423. e-mail Rev A. October 2003. Table of Contents Getting 1. Product 1. Unpacking the 2. The Trimline Circuit 2. Power 5. Logic Input 6. Serial Communications 8. Notes on RS-485 Multi-drop 10. Light Block 11. Setting the Timer 12. Setting the Timer Baud 12. Using the Timer Configuration 13. Installing the Configuration 13. Establishing a Link with the 14. Configuring Timer 18. Configuring Light Block 19. Testing the 20. Timer Configuration 21. In Case of 24. Contacting American LED-gible 24. Product 25. Limited 26. ASCII 27. Connection 29. Trimline Timer Owners Manual PB-2149-423 Rev A. Getting Started Thank you for your confidence in AMERICAN LED-gible.

Trimline Timer Owners Manual PB-2149-423 Rev A 1.2 Unpacking the Unit Every Trimline timer is carefully tested, both mechanically and electrically, before shipment.

Tags:

  Manual, Owner, Unit, Owners manual

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Owners Manual TIME - LED Andon

1 The Trimline Series Timer with Light Block Owners Manual (Firmware PP-2110-382A). TIME. American LED-gible Inc. 1776 Lone Eagle St. Columbus, OH 43228. (614) 851-1100 Phone (614) 851-1121 Fax www PB-2149-423. e-mail Rev A. October 2003. Table of Contents Getting 1. Product 1. Unpacking the 2. The Trimline Circuit 2. Power 5. Logic Input 6. Serial Communications 8. Notes on RS-485 Multi-drop 10. Light Block 11. Setting the Timer 12. Setting the Timer Baud 12. Using the Timer Configuration 13. Installing the Configuration 13. Establishing a Link with the 14. Configuring Timer 18. Configuring Light Block 19. Testing the 20. Timer Configuration 21. In Case of 24. Contacting American LED-gible 24. Product 25. Limited 26. ASCII 27. Connection 29. Trimline Timer Owners Manual PB-2149-423 Rev A. Getting Started Thank you for your confidence in AMERICAN LED-gible.

2 You have selected one of the best-built, high-quality, precision-engineered products available today. Our products are designed to give you years of trouble-free enjoyment. We appreciate your support, and we will do everything we can to keep you happy with your purchase for many years to come. After all, you are the reason we are in business! Product Description The Trimline series numeric marquees, are our most cost effective numeric marquees. Trimline series marquees are available with or " tall modules. " tall modules provide data visibility up to 125 feet away. " tall modules provide data visibility up to 200 feet away. Trimline series marquees use latched modules instead of multiplexed modules resulting in a brighter and more consistent display. Basic units are constructed using high efficiency red modules, however optional green or amber modules are available.

3 Optional high-brightness red modules are also available for applications with high ambient lighting conditions. Basic single sided NEMA-1 units are housed in a painted steel enclosure designed to be bolted to the wall. Screw terminals are provided within the enclosure for connection of 120 VAC power, 120 VAC or 24 VDC. Start/Stop/Reset inputs and RS-232/RS-485 serial communications. For harsher environments, Trimline marquees are housed in a rugged NEMA-12 enclosure constructed from painted 16 gauge steel with a " acrylic lens. NEMA-12 units are suitable for use in most industrial and factory environments. NEMA-12 enclosures can optionally be upgraded to NEMA-4 specifications. Optional stainless steel enclosures are also available for food processing applications. The Trimline Timer with Light Block is designed to be a versatile solution for most Manual production timing applications.

4 The timer can easily be configured to time up, or down. The timer can automatically reset and start timing again, or halt until a button is pressed. The associated light block can illuminate green, amber, and red over user configurable time spans. TIME. Page 1. Trimline Timer Owners Manual PB-2149-423 Rev A. Unpacking the unit Every Trimline timer is carefully tested, both mechanically and electrically, before shipment. Inspect the timer for damage, which may have occurred in transit. If there is evidence of damage or the timer fails to operate, file a claim with the shipper and notify American LED-gible. Save the shipping materials for inspection. Carefully remove the timer from the shipping carton. Then mount, or set the timer in a location where the unit is readily visible. The Trimline Timer Circuit Board Take a few moments to become familiar with the Trimline timer circuit board.

5 There are two versions of the board, one with " tall digits, and one with " tall digits. Both versions of the circuit board may be shortened from six digits to four digits by cutting off the two most significant digits of the display. Both boards have eight indicator lamps that can be quite helpful when troubleshooting problems:L1 lights when the start input is asserted, L2 lights when the stop input is asserted, L3 lights when the reset input is asserted, L4. lights when the n/c input is asserted, L5 lights when the RS-485 transmitter is on; L6 lights when the board is transmitting serial data; L7 lights when the board is receiving serial data; and L8 lights when power is applied to the board. Trimline Circuit Board, IC Side View Main 120 VAC Main Serial Logic Level Example Alternate 120 VAC Power and Logic Communications Selection Configuration Power Connector Input Connector Connector Jumpers Switch Settings Alternate Serial DB9 Communications Configuration Switches Firmware EPROM Output Relay Communications Connector Selection Jumpers Address / Baud / Misc in a Socket Connector Page 2.

6 Trimline Timer Owners Manual PB-2149-423 Rev A. Trimline Circuit Board, Side View Logic Input Indicator Serial Communications Power Indicator Lamps (4) Indicator Lamps (3) Lamp Trimline Circuit Board, IC Side View Main 120 VAC Main Serial Logic Level Example Alternate 120 VAC Power and Logic Communications Selection Configuration Output Relay Power Connector Input Connector Connector Jumpers Switch Settings Connector Alternate Serial DB9 Communications Configuration Switches Firmware EPROM. Communications Connectors Selection Jumpers Address / Baud / Misc in a Socket Page 3. Trimline Timer Owners Manual PB-2149-423 Rev A. Trimline Circuit Board, Side View Logic Input Indicator Serial Communications Power Indicator Lamps (4) Indicator Lamps (3) Lamp Page 4. Trimline Timer Owners Manual PB-2149-423 Rev A. Power Installation Bring the power and serial communications wiring to the timer separately through conduit, to avoid noise problems.

7 Power wires should be American Wire Gauge #16 with a 600 volt insulation rating. Standard timers are shipped without external connections in the enclosure. Power wiring is terminated within the unit on screw terminals appropriate for 16 AWG wire. Typical power wiring to the timer is shown below. Typical Power Wiring NEUT 1) 120 VAC NEUT. HOT 2) 120 VAC HOT. EARTH. 3) EARTH. SWITCH 4) POWER SWITCH. SWITCH 5) POWER SWITCH. 6) START. 7) STOP. 8) RESET. 9) n/c 10) INPUT COMMON. 2 RXD. 1) RS-232 OUT. 3 TXD. 2) RS-232 IN. 5 GND. 3) RS-232 GND. 4) RS-485- 5) RS-485+. 6) RS-485 GND. Typical RS-232 Wiring Connect 120 VAC Neutral to pin 1, 120 VAC Hot to pin 2, and Earth Ground to pin 3. A switch suitable for 120 VAC power may be connected across pins 4 and 5 to control 120 VAC power to the timer. Otherwise pins 4. and 5 of the power connector must be jumpered or the timer will fail to operate.

8 Maximum power draw is 30W per display side. Page 5. Trimline Timer Owners Manual PB-2149-423 Rev A. Logic Input Wiring The start, stop, and reset logic inputs are designed to be connected to momentary normally open push button switches. Pushing the start button makes the timer begin timing. Pressing the stop button makes the timer stop timing. Pressing the reset button resets the timer and optionally stops or starts timing. The logic inputs are optically isolated and passive in nature as shown is the schematic below. To assert any input, apply a voltage between logic common and the desired input terminal. 120 VAC logic levels are selected by removing all four shorting jumpers from the option header. 24 VDC logic levels are selected by installing all four shorting jumpers in the option header as shown below. 120 VAC Logic 24 VDC Logic Jumpers Removed Jumpers Installed 1 1.

9 2 2. 3 3. 4 4. Page 6. Trimline Timer Owners Manual PB-2149-423 Rev A. Typical wiring to the timer logic inputs is shown below. Typical 120 VAC Logic Input Wiring (Jumpers Removed). KT-2764-033. 1) 120 VAC NEUT. 2) 120 VAC HOT. 3) EARTH. 120 VAC HOT. 4) POWER SWITCH. 5) POWER SWITCH. 6) START. 7) STOP. 8) RESET. 9) n/c 10) INPUT COMMON. 120 VAC NEUT. 1) RS-232 OUT. 2) RS-232 IN. 3) RS-232 GND. 4) RS-485- 5) RS-485+. 6) RS-485 GND. Page 7. Trimline Timer Owners Manual PB-2149-423 Rev A. Serial Communications Installation Later in this Manual , we will describe the process of using a PC to configure one or more timers using the free PD-2116-062 configuration tool supplied with the timer. Using this tool, the timer will be configured to time up or down, and illuminate the light block various colors at specified times. In order to use the configuration tool, the PC serial port will have to be connected to a single timer or an RS-485 network of timers.

10 The wiring may be temporary, or permanent. The advantage to permanent wiring is that it makes future configuration changes to the timer easier. Timer configuration is stored in super-capacitor backed ram and will be retained for a minimum of two weeks without 120 VAC power applied to the unit . For a single timer within 50 feet of the PC, RS-232 is preferable to RS-485. RS-232 is simpler, and RS-232 serial ports are very common on computers and industrial control systems. RS-485 is more complex, and RS-485. serial ports are far less common. An external RS-232 to RS-485 communications converter may be required. However, there are situations where using RS-485 for communication is justified. RS-485 can be used to communicate with a timer up to 4000 feet away. Additionally RS-485 allows you to construct a network of up to 63 timers.