PELLA INSTALLATION INSTRUCTIONS …

PELLA INSTALLATION INSTRUCTIONS . brickmould AND FLUSH FLANGE WINDOWS. THE FOLLOWING INSTALLATION METHODS ARE INCLUDED IN THIS BOOKLET: New Construction INSTALLATION of Wood brickmould Windows in Wood Framed Walls After Building Wrap New Construction INSTALLATION in Masonry Construction for Flush Flange or Wood brickmould Windows Pocket Replacement into Aluminum Frames in Stucco Walls for Flush Flange Windows Full Frame replacement Full Frame Replacement of wood brickmould products with new PELLA EnduraClad . Exterior Trim or Wood brickmould Products Full Frame Replacement in Stucco Walls for Flush Flange Windows Full Frame Replacement in Masonry Construction with Stucco for ush ange windows These INSTRUCTIONS were developed and tested for use with wall systems designed to manage water. These INSTRUCTIONS are not to be used with any other construction methods or window frame types. INSTALLATION INSTRUCTIONS for use with other construction methods or frame types may be obtained from PELLA Corporation, your local PELLA retailer or Building designs, construction methods, building materials, and site conditions unique to your project may require an INSTALLATION method different from these INSTRUCTIONS and/or additional care.

BMFF – C PELLA INSTALLATION INSTRUCTIONS BRICKMOULD AND FLUSH FLANGE WINDOWS Always read the Limited Warranty before …

Tags:

  Installation, Instructions, Pella, Pella installation instructions, Brickmould, Pella installation instructions brickmould and

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PELLA INSTALLATION INSTRUCTIONS …

1 PELLA INSTALLATION INSTRUCTIONS . brickmould AND FLUSH FLANGE WINDOWS. THE FOLLOWING INSTALLATION METHODS ARE INCLUDED IN THIS BOOKLET: New Construction INSTALLATION of Wood brickmould Windows in Wood Framed Walls After Building Wrap New Construction INSTALLATION in Masonry Construction for Flush Flange or Wood brickmould Windows Pocket Replacement into Aluminum Frames in Stucco Walls for Flush Flange Windows Full Frame replacement Full Frame Replacement of wood brickmould products with new PELLA EnduraClad . Exterior Trim or Wood brickmould Products Full Frame Replacement in Stucco Walls for Flush Flange Windows Full Frame Replacement in Masonry Construction with Stucco for ush ange windows These INSTRUCTIONS were developed and tested for use with wall systems designed to manage water. These INSTRUCTIONS are not to be used with any other construction methods or window frame types. INSTALLATION INSTRUCTIONS for use with other construction methods or frame types may be obtained from PELLA Corporation, your local PELLA retailer or Building designs, construction methods, building materials, and site conditions unique to your project may require an INSTALLATION method different from these INSTRUCTIONS and/or additional care.

2 Determining the appropriate INSTALLATION method is the responsibility of you, your architect, or construction professional. Always read the Limited Warranty before purchasing or installing PELLA products. By installing this product, you are acknowledging that this Limited Warranty is part of the terms of the sale. Failure to comply with all PELLA INSTALLATION and maintenance INSTRUCTIONS may void your PELLA product warranty. See written Limited Warranty for details, including exceptions and limitations at , or contact PELLA Customer Service at 877-473-5527. BMFF C Revised 04/16/2018 2018 PELLA Corporation BM-FF_Booklet FULL FRAME OR SASH REMOVAL WHEN PREPARING TO INSTALL A NEW WINDOW WITH. brickmould OR FLUSH FLANGE. CAUTION: Many windows in older homes are painted with lead-based paint. Removal of old windows may disturb this paint. Proper precautions must be taken to minimize exposure to dust and debris.

3 Consult state or local authorities and/or go to for more information. TOOLS REQUIRED: Utility knife Pry bar Hammer Heat gun Angle grinder Phillips and Standard Reciprocating saw Putty knife Deglazing wheel screwdrivers REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT. B. Apply adhesive lm or duct tape to the glass to prevent breakage. ALUMINUM SASH AND/OR FRAME REMOVAL. A. Score the paint or varnish between the interior trim and the wall or between the drywall return and the window frame to minimize damage. (Frame removal only). B. Remove the interior trim. C. Score the sealant or paint between the exterior siding or brick and the window frame. E. D. Remove the screen and vent sash from the old window. If it is not removable, see steps G-I. E. Remove the division bar by removing the screws at the ends or cutting it with a reciprocating saw. F. Remove the other sash/panel. Remove any screws holding the xed sash.

4 Slide it and lift it out of the channel (sliding windows) or tilt it and release it from the balance assembly (hung windows). If the sashes are not removable or the glass is sealed to the frame: G H. G. Remove the glazing bead using a putty knife or small pry bar. H. H. For single pane windows with divided lights (grids). Use an angle grinder with a cut-off wheel to cut the end of the bars where they intersect with the sash or frame. This will allow the window glass to be removed more quickly. I. Heat the glazing seal using an electric heat gun. J. While applying heat, press a de-glazing wheel between the glass and sash or frame. Continue around the perimeter of the sash or panel. Apply J. light, constant pressure to separate the glass from the sash or frame. Dispose or recycle of the glass properly. I. NOTE: Wear appropriate personal protective equipment and keep the heat source away from ammable materials.

5 Stop here for pocket replacement, complete steps K-L for full frame replacement. K. Cut through the frame using a reciprocating saw. L. Pry the frame away from the brick or siding. Use a block of wood under L K. the pry bar to protect interior or exterior nishes. Dispose or recycle of the frame materials properly. brickmould FRAME REMOVAL. A. Score paint or varnish between the interior trim and the wall with a sharp utility knife. NOTE: This will minimize the damage to the interior wall and trim. BB D. D. B. Remove the interior trim. Remove the interior trim from all the four sides of the window including the stool at the bottom of the window. If the interior trim is being reused, pull the nails out through the back side of the board with nipper pliers. C. Cut the exterior sealant line between the exterior brickmould or trim and the exterior siding or wall cladding. D. Remove the exterior brickmould or at trim.

6 CAUTION: Some windows may come out of the opening as the exterior trim is removed. NOTE: DO NOT disturb existing head ashings. E. Remove the window frame. Consult with local providers and authorities to recycle or properly dispose of old window components. BMFF 2 Revised 04/16/2018 2018 PELLA Corporation BM-FF_Booklet PREPARING FOR brickmould OR FLUSH FLANGE WINDOW INSTALLATION . YOU WILL NEED TO SUPPLY: TOOLS REQUIRED: Moisture Resistant shims/spacers Tape measure Fasteners (see frame anchor INSTRUCTIONS and tables at the end of this booklet) Level Closed cell foam backer rod/sealant backer Square PELLA SmartFlash foil backed butyl window and door ashing tape or equivalent. Hammer Low expansion, low pressure polyurethane insulating window and door foam sealant Scissors or utility knife DO NOT use high pressure or latex foams. Small at blade screwdriver PELLA Window and Door INSTALLATION Sealant or equivalent high quality, multi-purpose Sealant Gun sealant (1 tube per window) SEALANT.

7 SEALANT. Screw Gun with a Phillips Driver bit 1/8" Allen wrench Note: Other construction materials may be required. Read and understand the INSTRUCTIONS and inspect the wall conditions before you begin. TWO OR MORE PEOPLE WILL BE REQUIRED FOR THE WINDOW INSTALLATION . Store windows in upright position, out of direct sunlight. PREPARING FOR INSTALLATION . A. Remove plastic wrap and cardboard packaging from the window. Do not Pull screen near cut checkrail bands (if present) or remove plastic or foam shipping spacers shipping clip located between the window sash and frame. DO NOT open the window until it is securely fastened. Shipping Clip DISCARD DISCARD. PUSH. B. Inspect the product for any damage such as cracks, dents or scratches. DO. C. PUSH. NOT install damaged windows. C. C. Remove screens and hardware (if necessary). Label them and set aside in a protected area. Windows with Half Screens: From the exterior, pull one side of the screen near the shipping clips until the clips disengage from the frame.

8 Rotate the shipping clips toward the exterior of the screen until they snap free from the screen. #6 x 5/8 corrosion resistant screws Half screens of some vinyl windows can be removed from the interior. 6 from end D. Pre-Drill INSTALLATION holes or install clips (if necessary). See frame anchor C. INSTRUCTIONS at the end of this booklet." Lip E. Before INSTALLATION , remove dirt and debris from all surfaces of the opening. F. Read the entire instruction before proceeding. D. D. These INSTRUCTIONS were developed and tested for use with wall systems designed to manage water. These INSTRUCTIONS are not to be used with any other construction methods or window frame types. INSTALLATION INSTRUCTIONS for use with other construction methods or frame types may be obtained from PELLA Corporation, your local PELLA retailer or Building designs, construction methods, building materials, and site conditions unique to your project may require an INSTALLATION method different from these INSTRUCTIONS and/or additional care.

9 Determining the appropriate INSTALLATION method is the responsibility of you, your architect, or construction professional. Always read the Limited Warranty before purchasing or installing PELLA products. By installing this product, you are acknowledging that this Limited Warranty is part of the terms of the sale. Failure to comply with all PELLA INSTALLATION and maintenance INSTRUCTIONS may void your PELLA product warranty. See written Limited Warranty for details, including exceptions and limitations at , or contact PELLA Customer Service at 877-473-5527. BMFF 3 Revised 04/16/2018 2018 PELLA Corporation BM-FF_Booklet WOOD brickmould WINDOW AFTER BUILDING WRAP . FOR USE IN WOOD FRAME WALLS. Sill Flashing Tape #1. Sill Flashing Tape #2. Water Resistive Barrier Sheathing Framing 1 PREPARE THE OPENING. Refer to the INSTALLATION preparation section at the beginning of this 2 SETTING AND FASTENING THE WINDOW.

10 A. Apply sealant to the back of the brickmould or at casing. booklet. B. Insert the window into the opening by placing the window sill on the sill spacers and tilting the window up. Center the window between jambs. A. Con rm the window will t Water Resistive Barrier Water Resistive Barrier the opening. Measure all 1st cut 1st cut 6 6 . four sides of the opening EXT. ERIO. to make sure it is 1/2" to 6 6 . R. 3rd cut 2nd cut 3/4" larger than the window INTE. RIOR. in both width and height 1C. 1B 1B. 1C. including subsill. On larger openings; measure the 2nd 3rd cut 2A 2B. cut width and height in several places to ensure the header or studs are not bowed. NOTE: 1-1/2" or more of solid Exterior Exterior wood blocking is required around the perimeter of the opening. Fix any problems with the rough opening before proceeding. 1D 1D. 1C C. Level the window across the head. Adjust the sill 2D.