Example: bankruptcy

PERFORMANCE DATA CERTIFIED ... - dms.hvacpartners.com

40 RUAP ackaged Air---Handling Units60 Hzwith Puronr(R---410A) RefrigerantSi ze s 07 --- 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS FAN COIL ACCESSORYDIMENSION PRINTSC opyright 2014 Carrier W. Morris , IN 46231 Edition Date: 05/14 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without No:40 RUA--- 7 --- 3 0 --- 0 1 S BReplaces: 40RU---03SB2 Job Data:Location:Buyer:Buyer #:Carrier:Unit Number:Model Number:Unit Designation: CERTIFIED to ISO9001 DESCRIPTIONThe 40 RUA units are completely packaged directexpansion air--handling units offering the ultimate ininstallation ease and flexibility.

3 SUBMITTAL DATA Job Name Architect Engineer Contractor Unit Designation FACTORY--INSTALLED OPTIONS (FIOPs) j Fan Motor Options S Standard Motor/Standard Drive

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PERFORMANCE DATA CERTIFIED ... - dms.hvacpartners.com

1 40 RUAP ackaged Air---Handling Units60 Hzwith Puronr(R---410A) RefrigerantSi ze s 07 --- 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS FAN COIL ACCESSORYDIMENSION PRINTSC opyright 2014 Carrier W. Morris , IN 46231 Edition Date: 05/14 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without No:40 RUA--- 7 --- 3 0 --- 0 1 S BReplaces: 40RU---03SB2 Job Data:Location:Buyer:Buyer #:Carrier:Unit Number:Model Number:Unit Designation: CERTIFIED to ISO9001 DESCRIPTIONThe 40 RUA units are completely packaged directexpansion air--handling units offering the ultimate ininstallation ease and flexibility.

2 Combined with Carrier38A Series condensing units these packaged air handlingunits offer system capacities from 6 up to 30 tons. Theseunits may be installed in either the vertical or horizontalconfiguration with no modifications. Powerful fan systemsallow easy adaptation to existing ductwork. Heatingcapability is provided by electric heaters, hot water coilsor steam FEATURESSP uronR(R--410A) HFC refrigerantSCleanable insulation treated with an anti--microbial agentSTwo slopped condensate pans on each unit forhorizontal or vertical applicationsS2--inch filtersSPowerful belt--driven forward curved fansSFactory--installed fan motor and contactorSRefrigerant metering devices (TXV s)

3 Factory--installedSEasy maintenance removal of a single panel allowsaccess to virtuallyall componentsSSingle refrigerant circuit on 07 and 08 models, dualrefrigerant circuit on 12 to 30 models. Dual circuitmodels can be field modified for use on single circuitcondensing ;dualbloweron14to30 terminal block for control wiring connectionSOptional Staged Air Volume (SAVt) system with2--speed indoor fan VFD controller (12--30 models)SStandard one--year warrantyPERFORMANCE DATAT otal Cooling CapacityMBtuhSensible Cooling CapacityMBtuhEntering Air_Fdb_FwbAirflowCFME xternal Static Pressurein.

4 WgRPM, BHPS aturated Suction Temperature_FTotal Heating CapacityMBtuhELECTRICAL DATAP ower Supply to UnitVoltsPhaseHzMinimum Circuit AmpsMaximum Overcurrent Protection40 RUA3 SUBMITTAL DATAJob NameArchitectEngineerContractorUnit DesignationFACTORY--INSTALLED OPTIONS (FIOPs)jFan Motor OptionsSStandard Motor/Standard DriveSStandard Motor/Medium DriveSHigh Motor/High DrivejStaged Air Volume (SAV) system utilizes a VariableFrequency Drive (VFD) to automatically adjust theindoor fan motor for 2 speed indoor fan motor to ASHRAE 2010 Standard Available on 12 to 30 models with two stagecooling CabinetOPTIONAL WARRANTIESjComplete Unit Parts only up to 5 yearsjComplete Unit Parts and Labor up to 5 yearsMany other optional warranties are theCommercial Start--Up and Optional ExtendedWarranty Priceprice pages for further INSTALLED ACCESSORIESjEconomizer -- Enthalpy Controlled --Standard Leak designjEconomizer temperature dry bulb

5 Controlled UltraLOW LEAK -- EconoMi$er X with solid--state W7220controller, gear--driven, modulating damper, springreturn actuator. Supply and outdoor air sensors, and CO2sensor compatible, for use in electro mechanical controlsonly. Also includes return and outside air damper leakagethat meets Title 24 section meets California Title 24 Section FaultDetection and Diagnostic (FDD) Control for W7220 Controller only,(One required for single enthalpy, two required fordifferent enthalpy)jDisplay Kit for Variable Frequency Drive (VFD),Staged Air Volume System.

6 Allows additional set upand diagnostics of the unit VFD controller. Can be unitmounted or used with any other compatible VFDmodel as a reusable Heat:Volts,kWjHot Water Coil (2 row)jCondensate Overflow Switch AssemblejDischarge Plenum*jDischarge Plenum (painted)*jReturn Air GrillejReturn Air Grille (painted)jSteam Coil (1 row)jFloor Mount Base (Subbase)jFloor Mount Base (Subbase) -- PaintedjOverhead Suspension BracketsjCO2 Room Sensor -- Wall mount(Aspirator Box required for duct mounting)jThermostats* Discharge Plenums are shipped knocked down and require fieldassembly.

7 Cannot be used with electric heat or DIMENSION 40 RUA07, 08, 12C1420040 RUA5 CERTIFIED DIMENSION 40 RUA14, 16, 25C1420140 RUA6 CERTIFIED DIMENSION 40 RUA28, 30C1420240 RUA7 CERTIFIED DIMENSION -- ACCESSORIES FOR 40 RUA07, 08, 12C0920640 RUA8 CERTIFIED DIMENSION -- ACCESSORIES FOR 40 RUA14, 16, 25C0920740 RUA9 CERTIFIED DIMENSION -- ACCESSORIES FOR 40 RUA28, 30C0946340 RUA10 CERTIFIED DIMENSION -- ACCESSORIES FOR 40 RUA07, 08, 12C0920840 RUA11 CERTIFIED DIMENSION -- ACCESSORIES FOR 40 RUA14, 16, 25C0920940 RUA12 CERTIFIED DIMENSION -- ACCESSORIES FOR 40 RUA28, 30C0946440 RUA13 CERTIFIED DIMENSION -- ACCESSORIESC0946540 RUA1440 RUA