Example: air traffic controller

Product Data

158 MCB4 --- WAY MULTIPOISE FIXED --- CAPACITYCONDENSING GAS FURNACEI nput Rates: 40,000 thru 138,000 BtuhProduct DataA05104 HIGH EFFICIENCY AND FLEXIBILITYDESIGNED TO MEET THE NEEDS OFNEW HOMESThe model 58 MCB combines high efficiency with flexibility tomeet the changing needs of new home construction. The unique4--way, multipoise design of the 58 MCB allows for installation inupflow, downflow, horizontal left, and horizontal rightorientations, meaning it is perfect for a variety of installationapplications. With the exception of the 140 size unit, all sizes of the58 MCB can be installed in a manufactured ( mobile ) home whenthe optional kit is used and in installations with elevations up to10,000 ft (140 size unit limitation 7,000 ft). The furnace is factoryconfigured for upflow application but can easily be made ready fordownflow or horizontal installation. With the exception of the 140size, all sizes can be installed with 2--pipe or 1--pipe venting. The140 size can be installed only as a 2--pipe applications offer the advantage of reduced spacerequirements by locating the furnace in an attic or crawlspace,freeing space formerly dedicated to a furnace or utility 58 MCB is specifically designed to meet the needs of homebuilders and new home owners.

NEW HOMES The model 58MCB combines high efficiency with flexibility to ... manufactured (mobile) home when the optional kit is used. Refer ... FUSE 3-AMP 0.5 AMP@24VAC HUM TEST/TWIN G Com W Y R 24V 120 180 90 150 BLOWER OFF-DELAY PLT 1 COOL HEAT SPARE-1 SPARE-2 EAC-1 1-AMP@ ...

Tags:

  Mobile, Home, Manufactured

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Product Data

1 158 MCB4 --- WAY MULTIPOISE FIXED --- CAPACITYCONDENSING GAS FURNACEI nput Rates: 40,000 thru 138,000 BtuhProduct DataA05104 HIGH EFFICIENCY AND FLEXIBILITYDESIGNED TO MEET THE NEEDS OFNEW HOMESThe model 58 MCB combines high efficiency with flexibility tomeet the changing needs of new home construction. The unique4--way, multipoise design of the 58 MCB allows for installation inupflow, downflow, horizontal left, and horizontal rightorientations, meaning it is perfect for a variety of installationapplications. With the exception of the 140 size unit, all sizes of the58 MCB can be installed in a manufactured ( mobile ) home whenthe optional kit is used and in installations with elevations up to10,000 ft (140 size unit limitation 7,000 ft). The furnace is factoryconfigured for upflow application but can easily be made ready fordownflow or horizontal installation. With the exception of the 140size, all sizes can be installed with 2--pipe or 1--pipe venting. The140 size can be installed only as a 2--pipe applications offer the advantage of reduced spacerequirements by locating the furnace in an attic or crawlspace,freeing space formerly dedicated to a furnace or utility 58 MCB is specifically designed to meet the needs of homebuilders and new home owners.

2 home builders benefit from the58 MCB s unmatched flexibility and by building a reputation ofusing quality appliances in homes. home owners benefit by energysavings from one of the most important home components of the 58 MCB represent the finest in the surface ignition (HSI) and a control center provide reliable andefficient ignition. The combustion inducer is unique in thatefficient operation is achieved in any type of installation. Standard2--in. (51 mm) PVC pipe connects the combustion--air and ventpipes to the 58 MCB is a standard part of a quality--built new home . Thishigh efficiency furnace will provide years of quality service tohome builders and home owners with other Carrier furnaces, this model is designed to work as apart of the total home comfort system which includes elements forcooling, air cleaning, humidification, ventilation, and FEATURES / BENEFITSS erpentufft Exclusive Serpentuff coating, a patentedpolypropylene laminate is used on the secondary heat HeattIgniter The Carrier unique SiN igniter is not onlyphysically robust but it is also electrically robust.

3 It is capable ofrunning at line voltage and does not require complex voltageregulators as do other brands. This unique feature further enhancesthe reliability of the 58 MCB gas furnace and continues Carrier stradition of technology leadership and innovation in providing areliable and durable Center Controls sequencing and furnace with a component test feature and status indicator lightto assist in troubleshooting. Control times blower start after mainburners ignite to eliminate cold air blowing into or Non--direct Venting The 58 MCB can be installed as a1 pipe--Non-- Direct vent or 2 pipe/Direct vent furnace except the140 size which can be installed as 2--pipe only. This providesadded flexibility to meet diverse installation Blower Speed For precise airflow selection ofheating or cooling One piece, seamless wraparound construction ofprepainted galvanized steel resists Products Venting The combustion--air and ventpipes can terminate through a side wall or through the roof whenused with a factory authorized vent termination Foil--faced insulation in heat exchanger section of thecasing minimizes heat The 58 MCB units are CSA ( and )design certified for use with natural and propane gases.

4 Thefurnace is factory--shipped for use with natural gas. A CSA( ) listed gas conversion kit is required to convertfurnace for use with propane gas. The efficiency is GAMA efficiency rating certified. The 58 MCB meets California AirQuality Management District emission requirements. Except forthe 140 size unit, all sizes of the 58 MCB can be installed in amanufactured ( mobile ) home when the optional kit is used. Referto Vent Table for elevation Registration The 58 MCB is engineered andmanufactured under an ISO 9001 registered quality NUMBER NOMENCLATURE58 MCB0404-Way Multipoise Fixed-CapacityDirect-Vent (2-Pipe) and Non-Direct Vent (1-Pipe) Condensing Gas FurnaceInput Rate040 40,000 Btuh060 60,000 Btuh080 80,000 Btuh100 100,000 Btuh120 120,000 Btuh140 138,000 Btuh10008 Cooling Size Airflow(Nominal 400 CFM per12,000 Btuh Cooling)08 800 CFM12 1200 CFM16 1600 CFM20 2000 CFMS eriesBLWNUETRALSTATUS CODE LEDSEC-2 SEC-1 EAC-2 L2 FUSE AMP@24 VACHUMTEST/TWIN G Com W Y R24V120 18090 150 BLOWER OFF-DELAYPLT 1 COOL HEATSPARE-1 SPARE-2 EAC-11-AMP@115 VACPR-1L1PL2 124-V THERMOSTATTERMINALS3-AMP FUSELED OPERATION &DIAGNOSTIC LIGHT115-VAC(L2)NEUTRALCONNECTIONSCOOLHE ATSPARE-1 SPARE-2 BLOWER SPEEDSELECTION TERMINALSEAC-1 TERMINAL(115-VAC AMP MAX.)

5 115 VAC (L1) LINEVOLTAGE CONNECTIONPL2-HOT SURFACEIGNITER & INDUCERMOTOR CONNECTORPL1-LOW VOLTAGE MAINHARNESS CONNECTORTRANSFORMER 24-VACCONNECTIONSHUMIDIFIER TERMINAL(24-VAC AMP MAX.)TWINNING AND/ORCOMPONENT TESTTERMINALBLOWER OFF-DELAYJ2J2 JUMPERPLTA92505 HEAT EXCHANGERSCONTROL CENTERA02172 INDUCER ASSEMBLYA0210058 MCB3121168109764521131418315161719A02173 NOTE:SThe 58 MCB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory--authorized and listedaccessory conversion location and actual controls may be different than shown sight glass for viewing burner assembly (inside), operates with energy--sav-ing, inshot burners and hot surface igniter for safe,dependable intake connection to ensure con-taminant--free air (right or left side). gas valve, safe, efficient, features 1 gascontrol with 2 internal shutoff box for 115--v electrical power supply.(right or left side) outlet uses sealed PVC pipe to carry vent gasesfrom the furnace s combustion system (right or leftside).

6 Condensing heat exchanger (inside),wrings out more heat through condensation ofgases. Constructed with polypropylene--laminatedsteel to ensure switch ensures adequate flow of flueproducts through furnace and out vent motor pulls hot flue gases through the heatexchangers, maintaining negative pressure for ad-ded drain connection collects moisture con-densed during the combustion blower circulates air across the heatexchangers to transfer heat into the filter and retainer may be used for side or bot-tom return switch (manual reset) to prevent overtem-perature in burner serpentine heat exchanger (inside).Stretches fuel dollars with the S--shaped heat--flowdesign. Solid weld--free construction of corrosion--resistant aluminized steel means 3--amp fuse provides electrical and emitting diode (LED) on control center. Codelights are for diagnosing furnace operation and ser-vice access panel safety interlock (24v) behind control center provideslow--voltage power to furnace control center SIZE040---08040---12060---08060---12060- --16080---12 RATINGS AND PERFORMANCEI nput Btuh*40,00040,00060,00060,00060,00080,00 0 Output CapacityBTUH* (ICS)(Shaded capa-cities are spe-cified on ratingplate)Direct Vent (2 --- Pipe)Upflow37,00037,00056,00056,00056,00 074,000 Downflow37,00037,00056,00056,00056,00074 ,000 Horizontal37,00037,00056,00056,00056,000 74,000 Non --- Direct Vent (1 --- Pipe)Upflow37,00037,00056,00056,00056,00 074,000 Downflow37,00037,00056,00056,00056,00074 ,000 Horizontal37,00037,00056,00056,00056,000 74,000 AFUE%Nonweather-ized ICSD irect Vent (2 --- Pipe) --- Direct Vent (1 --- Pipe) Temperature Rise Range F ( C)30---60(17 --- 33)15---45(8 --- 25)45---75(25 --- 41)30---60(17 --- 33)20---50(11 --- 28)40---70(22 --- 39)

7 Certified External Static CFM}Heating8501125885106513201190 Cooling8951215900120015451245 ELECTRICALUnit Volts --- Hertz --- Phase115 --- 60 --- 1 Operating Voltage Range Min---Max**104---127 Maximum Unit Ampacity{{ Wire Size141414141414 Maximum Wire Length --- Ft (M)}}44( )37( )44( )38( )29( )36( )Maximum Fuse Size or Ckt Bkr Amps (Time---Delay Type Recommended)151515151515 Transformer (24v)40vaExternal Control Power AvailableHeating12vaCooling21vaAir Conditioning Blower RelayStandardCONTROLSL imit ControlSPSTH eating Blower Control (Off Delay)Factory---Set at 135 SecBurners (Monoport)223334 Gas Connection Size1/2 --- in. NPTGAS CONTROLSGas Valve (Redundant)ManufacturerWhite --- RodgersMin Inlet Pressure (In. wc) (Natural Gas)Max Inlet Pressure (In. wc) (Natural Gas)Ignition DeviceHot SurfaceBLOWER DATAD irect---Drive Motor HP (Permanent Split Capacitor)1/51/31/51/31/21/3 Motor Full Load (Nominal) --- Speeds1075---31075---41075---31075---4 Blower Wheel Diameter x Width --- In.

8 (mm)10 x 6(254 x152)10 x 7(254 x178)10 x 6(254 x152)10 x 7(254 x178)11 x 8(279 x203)10 x 7(254 x178)Filter Size --- In. (mm) --- Sold Separately(1) 16 x 25 x 3/4 (406 x 635 x 19)FACTORY---AUTHORIZED AND LISTED, DEALER---INSTALLED OPTIONSGas Conversion Kit --- Natural --- to --- PropaneKGANP4601 ALLGas Conversion Kit --- Propane --- to --- NaturalKGAPN3901 ALLT winning KitN/AKGATW0601 HSIN/AManufactured ( mobile ) home KitKGAMH0301 KITD ownflow Base**KGASB0301 ALLVent Termination Kit (Bracket Only for 2 Pipes) Vent Termination Kit (Single Exit) Freeze Protection KitKGAHT0101 CFPC ondensate Neutralizer Kit (Obtained Thru RCD)P908---0001 Side Filter Rack (Without Filter)---Upflow ONLYKGAFR0206 ALLE lectronic/Mechanical Air CleanerModel EACA, EZXCAB, or FILCABH umidifierModel HUMHeat/Energy Recovery VentilatorModel HRVUV LightsModel UVLDoor Gasket KitKGBAC0110 DGKU nframed Filter Permanent Washable 3/4---in. (19 mm) thick16 x 25 (406 x 635 mm)24 x 25 (610 x 635 mm)KGAWF1306 UFRKGAWF1506 UFR58 MCB5 SPECIFICATIONS (CONTINUED)UNIT SIZE080---16080---20100---16100---20120- --20140---20 RATINGS AND PERFORMANCEI nput Btuh*80,00080,000100,000100,000120,00013 8,000 Output CapacityBTUH* (ICS)(Shaded capa-cities are spe-cified on ratingplate)Direct Vent (2 --- Pipe)Upflow74,00074,00093,00093,000112,0 00127,000 Downflow74,00074,00093,00093,000112,0001 27,000 Horizontal74,00074,00093,00093,000112,00 0127,000 Non --- Direct Vent (1 --- Pipe)Upflow74,00074,00093,00093,000112,0 00 NADownflow74,00074,00093,00093,000112,00 0 NAHorizontal74,00074,00093,00093,000112, 000 NAAFUE%NonweatherizedICSD irect Vent (2 --- Pipe) --- Direct Vent (1 --- Pipe) Temperature Rise Range F ( C)30---60(17 --- 33)20---50(11 --- 28)45---75(25 --- 41)30---60(17 --- 33)40---70(22 --- 39)50---80(28 --- 44)

9 Certified External Static CFM}Heating128517851315169017201970 Cooling152519251570193020001990 ELECTRICALUnit Volts --- Hertz --- Phase115 --- 60 --- 1 Operating Voltage Range Min---Max**104---127 Maximum Unit Ampacity{{ Wire Size141214121212 Maximum Wire Length --- Ft (M)}}28( )31( )27( )30( )30( )30( )Maximum Fuse Size or Ckt Bkr Amps (Time---Delay Type Recommended)152015202020 Transformer (24v)40vaExternal Control Power AvailableHeating12vaCooling21vaAir Conditioning Blower RelayStandardCONTROLSL imit ControlSPSTH eating Blower Control (Off Delay)Factory---Set at 135 SecBurners (Monoport)445566 Gas Connection Size1/2 --- in. NPTGAS CONTROLSGas Valve (Redundant)ManufacturerWhite --- RodgersMin Inlet Pressure (In. wc) (Natural Gas)Max Inlet Pressure (In. wc) (Natural Gas)Ignition DeviceHot SurfaceBLOWER DATAD irect---Drive Motor HP (Permanent Split Capacitor)1/23/41/23/43/43/4 Motor Full Load (Nominal) --- Speeds1075---4 Blower Wheel Diameter x Width --- In. (mm)11 x 8(279x203)11 x 10(279x254)11 x 8(279x203)11 x 10(279x254)11 x 10(279x254)11 x 10(279x254)Filter Size --- in.

10 (mm) --- Sold Separately(1) 20 x 25 x 3/4(508 x 635 x 19)(2)16 x 25 x 3/4(406 x 635 x 19)FACTORY---AUTHORIZED AND LISTED, DEALER---INSTALLED OPTIONSGas Conversion Kit --- Natural --- to --- PropaneKGANP4601 ALLGas Conversion Kit --- Propane --- to --- NaturalKGAPN3901 ALLT winning KitKGATW0601 HSIN/AManufactured ( mobile ) home KitKGAMH0301 KITN/ADownflow Base**KGASB0301 ALLVent Termination Kit (Bracket Only for 2 Pipes) Vent Termination Kit (Single Exit) Freeze Protection KitKGAHT0101 CFPC ondensate Neutralizer Kit (Obtained Thru RCD)P908---0001 Side Filter Rack (Without Filter)---Upflow ONLYKGAFR0206 ALLE lectronic/Mechanical Air CleanerModel EACB, EZXCAB, or FILCABH umidifierModel HUMHeat/EnergyRecoveryVentilatorModel HRVUV LightsModel UVLDoor Gasket KitKGBAC0110 DGKU nframed Filter Permanent Washable 3/4---in. (19 mm) thick16 x 25 (406 x 635 mm)24 x 25 (610 x 635 mm)KGAWF1306 UFRKGAWF1506 UFR* Gas input ratings are certified for elevations to 2000 ft. (610 M) For elevations above 2000 ft.


Related search queries