Example: bachelor of science

Product Description Features, Functions, Benefits

April 20083-58 For more information visit: Contactors & Starters3 Advantage Full Voltage ControlProduct Family OverviewCatalog Number ECH2211 FADP roduct DescriptionSetting the Standard in Motor ControlEaton s Cutler-Hammer Advantage Motor Starters have extended operat-ing life in a physical space require-ment one half the size of conventional motor motor overcurrent protection accurate to 2% at maximum FLC, Advantage also maintains constant coil power regardless of varying con-trol circuit conditions, eliminating coil burnout, contact chatter and welding due to low voltage of fluttering control is designed with a full complement of features that make it the most versatile motor starter in the industry. Multifunction overload protection options provide application flexibility while reducing inventory. Communication capability extends benefits, allowing Advantage to be interactively linked to higher order control systems for monitoring, troubleshooting and advances incorporated in the Advantage design, such as pre-start diagnostics, increased accuracy and the ability to communicate with other systems, are benefits not realized in traditional motor , Functions, BenefitsAdvantage BreakthroughsTo achieve the level of benefits envi-sioned for Advantage controls at a competitive price, it was discovered early in the development process that simply improving existing design concepts would fall short of the mark.

April 2008 PG03300001E For more information visit: www.eaton.com NEMA Contactors & Starters 3-59 3 Advantage Full Voltage Control Product Family Overview Improved Protection and Motor

Tags:

  Feature, Descriptions, Eaton, Description features

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Description Features, Functions, Benefits

1 April 20083-58 For more information visit: Contactors & Starters3 Advantage Full Voltage ControlProduct Family OverviewCatalog Number ECH2211 FADP roduct DescriptionSetting the Standard in Motor ControlEaton s Cutler-Hammer Advantage Motor Starters have extended operat-ing life in a physical space require-ment one half the size of conventional motor motor overcurrent protection accurate to 2% at maximum FLC, Advantage also maintains constant coil power regardless of varying con-trol circuit conditions, eliminating coil burnout, contact chatter and welding due to low voltage of fluttering control is designed with a full complement of features that make it the most versatile motor starter in the industry. Multifunction overload protection options provide application flexibility while reducing inventory. Communication capability extends benefits, allowing Advantage to be interactively linked to higher order control systems for monitoring, troubleshooting and advances incorporated in the Advantage design, such as pre-start diagnostics, increased accuracy and the ability to communicate with other systems, are benefits not realized in traditional motor , Functions, BenefitsAdvantage BreakthroughsTo achieve the level of benefits envi-sioned for Advantage controls at a competitive price, it was discovered early in the development process that simply improving existing design concepts would fall short of the mark.

2 A new approach involving a higher level of technology was required. The result was the incorporation of three technical breakthroughs new current sensing monitoring, an energy-balanced contact closure system that increased life by decreasing electrical and mechanical wear and an intelligent coil controller optimizing the contact closing process based on varying control circuit condi-tions. Coordinating these break-throughs to provide enhanced motor control performance is concentrated in the SURE uses the right combination of brains and brawn in effecting a motor start. The power circuit of the contactor employs heavy-duty silver alloy contacts scientifically designed for long life. The addition of a uniquely developed application-specific micro-processor chip, regulates power sup-plied to the operating coil. The regulated closing profile is tailored to existing control circuit conditions. This results in an energy balanced system which reduces armature/magnet crash and contact bounce, extending mechanical and electrical 2008PG03300001 EFor more information visit: Contactors & Starters3 Advantage Full Voltage ControlProduct Family OverviewImproved Protection and Motor UtilizationThe motor circuit monitoring and over-load protection functions of Advan-tage starters are provided by three current sensors closely monitored by the microprocessor.

3 This sensor/microprocessor combination yields a protection scheme closely paralleling that of the motor heating damage boundary expressed in terms of currentand time. Accurate to 2%, Advantage allows full utilization of motor capability without motor damage or nuisance Heaters, Small SizeAdvantage starters eliminate the need for costly heater elements and their associated installation expense. Stan-dard overload protection functions include phase loss and unbalance protection, selectable trip class, automatic/manual reset and ground current Communications Capabilities Provide Two-Way ControlAdvantage also offers low cost communication capability. ON-OFF commands, status and motor data can be linked to automated control systems without the addition of costly sensors, I/O modules and transducers, in a language compatible with many computer-based software systems in use by 22 patents and proven in many years of operating experience in harsh industrial applications, Advan-tage motor starters and contactors offer the user unprecedented value at a price competitive with traditional and CertificationsNote:SeePage 18-2 for additional informa-tion on Standards and Certifications that apply to all Cutler-Hammer Enclosed Control products.

4 UL Listed cUL Listed (indicates appropriate CSA Standard investigation) ABS Type ApprovedApril 20083-60 For more information visit: Contactors & Starters3 Advantage Full Voltage ControlProduct Family OverviewCatalog Number Selection Table 3-46. Advantage Line Enclosed Control Catalog Numbering System Contact eaton for more information. Use with Sizes L 3, HMCP 600V applications 3-47. Magnet Coil Codes (System Voltage) When control power transformer modification codes (C1 C11) are used or when starter class includes CPT ( ECN07, 18), see Table 3-48for system voltage 3-48. Control Power Transformer Codes (System Voltage) E C A2 221 AAF-DesignA = Advantage NEMAC lassTable01 =02 =05 =06 =07=16 =17 =18 =22 =23 =24 =33 =34 =35 =36 =37 =38 =39 =40 =41 =42 =43 =44 =45 =46 =47 =48 =49 =50 =51 =52 =53 =54 =55 =62 =63 =64 =65 =68 =69 =70 =ContactorsReversing ContactorsNon-combination Non-reversing StarterNon-combination Reversing StarterNon-combination Non-reversing Starter, with CPTC ombination Non-reversing Starter Fusible DisconnectCombination Reversing Starterwith Disconnect SwitchCombination Reversing Starter Fusible/Non-fusible Disconnect with CPTC ombination Non-reversing Starter Circuit BreakerReversing, Combination with HMCP/ECombination with HMCP/E with CPTM ultispeed 2S2W Non-combinationMultispeed 2S1W CT or VT Non-combinationMultispeed 2S1W CH Non-combinationMultispeed with Disconnect Switch, 2S2 WMultispeed with Disconnect Switch, 2S1W CT or VTMultispeed with Disconnect Switch, 2S1W CHMultispeed with HMCP/E, 2S2 WMultispeed with HMCP/E, 2S1W CT or VTMultispeed with HMCP/E.

5 2S1W CHAutotransformer, Non-combinationAutotransformer, with Disconnect SwitchAutotransformer, with HMCP/EPart-Winding, Non-combinationPart-Winding, with Disconnect SwitchPart-Winding, with HMCP/EY-D, Open Transition, Non-combinationY-D, Open Transition, with Disconnect SwitchY-D, Open Transition, with HMCP/EY-D, Closed Transition, Non-combinationY-D, Closed Transition, with Disconnect SwitchY-D, Closed Transition, with HMCP/EStd Width Pump Panel, with Disconnect SwitchStd Width Pump Panel, with HMCP/EAutotransformer Pump Panel, Disconnect SwitchAutotransformer Pump Panel, HMCP/EPart-Winding Pump Panel, DisconnectPart-Winding Pump Panel, Circuit BreakerDuplex, Non-combinationDuplex, with Disconnect SwitchDuplex, with HMCP/E 3-50 3-51 3-523-53 NEMA SizeL =1 =2 =3 =Lower 1 Size 1 Size 2 Size 34 =5 =6 =Size 4 Size 5 Size 6 Modification CodesSee Page 16-40 Coil Voltage and/or Control TransformersSeeTables 3-47 and 3-48 Disconnect Fuse Clip RatingsA =B =C =D =E =F =None30A/250V R30A/600V R60A/250V R60A/600V R100A/250V RG =H =J =K =L =M =100A/600V R200A/250V R200A/600V R400A/250V R400A/600V R600A/250V RN =P =Q =R =S =T =600A/600V R800A/600V R1200A/600V R1600A/600V R2000A/600V Rby DescriptionHMCP/E or Breaker RatingsA =B =C =D =E =F =W =G =None3A7A15A30A50A70A100AH =J =K =L =M =N =P =Q =150A250A400A600A800A1000A1200A2000AR =T =5 =6 =7 =8 =9 =I =3000 Aby Description3A 7A 15A 30A 50A 100A Enclosure Type1 =2 =3 =4 =5 =6 =7 =8 =9 =Type 1 General PurposeType 3R RainproofType 4 Watertight (Painted Steel)Type 4X Watertight (304-Grade Stainless Steel)Type 4X Corrosion (Nonmetallic)

6 Type 7/9 Bolted Hazardous LocationType 7/9 Threaded Hazardous LocationType 12 Dust-TightType 4X 316-Grade Stainless SteelCover Control Starters10250T and E22 style, see Tables 3-19 3-21 Flange-Mounted ACM, see Table 3-49 Contactors3 = 3 PolesCodeMagnet CoilCodeMagnet CoilFN120/60110/50 ZBy DescriptionCode PrimarySecondaryCode PrimarySecondaryBCDE240/480 220/440 Wired for 240V240/480 220/440 Wired for 480V600/60 550/50208/60120/60 110/50120/60 110/50120/60 110/50120/60 HLMXZ277/60380/50415/50240/480/600 Wired for 480 VBy Description120/60110/50110/50120PG033000 01 EFor more information visit: Contactors & StartersApril 20083 Advantage Full Voltage ControlProduct Family OverviewCover ControlFlange Mounted Pilot ACM Devices NEMA 1, 12 OnlyForFactory Installed flange mounted pilot devices using Advantage Control Modules (ACMs), change the 9th character from A to Y and add one of the following (A49 through A62) Mod Code Suffixes to the Catalog Number.

7 In addition, one A63 Mod may be added if 3-49. Flange Mounted Pilot ACM Devices This device is not compatible with Advantage Starters on DeviceNet via the 3-11. Flange Mounted Pilot ACM DevicesOther Cover Control DevicesSeePage 3-21 in NEMA Contactors & Starters, Freedom Line. Flange Mounted Pilot DevicesDescriptionFactory InstalledField Installation KitsMod CodeSuffixCatalogNumberFull VoltageStatus Only with ResetSTART/STOPSTART/STOP/HOAON/OFF/AUTO A49A50A51A52 WPBFV1 WPBFV2 WPBFV3 WPBFV4 ReversingStatus Only with ResetFWD/REV/STOPFWD/REV/STOP/HOAA53A54A 55 WPBR1 WPBR2 WPBR32-SpeedStatus Only with ResetFAST/SLOW/STOPFAST/SLOW/STOP/HOAA56 A57A58 WPB2S1 WPB2S2 WPB2S3 Reduced VoltageStatus Only with ResetSTART/STOPSTART/STOP/HOAON/OFF/AUTO A59A60A61A62 WPBRV1 WPBRV2 WPBRV3 WPBRV4 Metering Module10 ft. Interconnect Cable6 ft. Interconnect Cable3 ft. Interconnect Cable1 ft. Interconnect JumperA63 WMETER WACM10 WACM6 WACM3 WACM1OL AlarmTr i pOL TripOL AlarmTr i pOL TripOL AlarmTr i pOL TripRESR esetRunOffOL AlarmTr i pOL TripRESR esetRESR esetRESR esetRunOffRunHANDSTARTSTOPSTARTSTOPOFFAU TOONOFFAUTOOffRunOffStatus OnlySTART/STOPC ontrolHAND/OFF/AUTO Controlwith START/STOP PushbuttonControl in HAND ModeON/ ( ) ( )April 2008PG03300001 EFor more information visit: Contactors & Starters3 Advantage Full Voltage ControlCombination Starters Fusible and Non-fusibleFeatures and Product Selection Full Voltage Solid-State Overload Relays 600V Maximum 100,000 AIC Short Circuit 600V MaximumTable 3-51.

8 Class ECA16 Combination Non-reversing Starter Fusible Disconnect For motor full load current (FLA) range of .47A with a to service factor and for motor hp range of 1/4 hp to 2 hp at 460V. All starters provided with coils for separate control. Starters for 50 Hz operation use 110V 50 Hz magnet coil. Change 8th character from F to N. All Type 12 enclosures are standardized with external reset. For inter-nal reset, order Mod Code R5. Type 12 enclosure is without safety door interlock. When safety door interlock is required, change seventh character from 8 to 9, ECA1618 FAC would become ECA1619 FAC. The Catalog Numbers listed in the Type 4X column are for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit : ECA16L4 FAB. To order Type 4X 316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14. Fuse clips are for Class R fuses only.

9 For H and J fuses see mods, Page 16-42. Size 6 includes control power transformer. ECA1611 FAANEMASizeMotorVoltageMaximumhpRatingDu alElementFusesMagnetCoilVoltage FuseClipAmps. Type 1 General PurposeType 3 RRainproofType 4X Watertight & Dust-Tight Stainless Steel Type 12 Dust-Tight Industrial ComponentStarter (Open)CatalogNumberCatalogNumberCatalogN umberCatalogNumberCatalogNumber1-L 200230112030 AECA16L1 FABECA16L2 FABECA16L4 FABECA16L8 FABW200 MLCFC460575212030 AECA16L1 FACECA16L2 FACECA16L4 FACECA16L8 FACW200 MLCFC12002307-1/212030 AECA1611 FABECA1612 FABECA1614 FABECA1618 FABW200M1 CFC4605751012030 AECA1611 FACECA1612 FACECA1614 FACECA1618 FACW200M1 CFC2200230101512060 AECA1621 FADECA1622 FADECA1624 FADECA1628 FADW200M2 CFC4605752512060 AECA1621 FAEECA1622 FAEECA1624 FAEECA1628 FAEW200M2 CFC32002302530120100 AECA1631 FAFECA1632 FAFECA1634 FAFECA1638 FAFW200M3 CFC46057550120100 AECA1631 FAGECA1632 FAGECA1634 FAGECA1638 FAGW200M3 CFC42002304050120200 AECA1641 FAHECA1642 FAHECA1644 FAHECA1648 FAHW200M4 CFC460575100120200 AECA1641 FAJECA1642 FAJECA1644 FAJECA1648 FAJW200M4 CFC520023075100120400 AECA1651 FAKECA1652 FAKECA1654 FAKECA1658 FAKW200M5 CFC460575200120400 AECA1651 FALECA1652 FALECA1654 FALECA1658 FALW200M5 CFC6200230150200120 600 AECA1661 EAMECA1661 BAMECA1662 EAMECA1662

10 BAMECA1663 EAMECA1663 BAMECA1668 EAMECA1668 BAMW200M6 CFC460575400600 AECA1661 CANECA1661 DANECA1662 CANECA1662 DANECA1663 CANECA1663 DANECA1668 CANECA1668 DANW200M6 CFCC over Mounted Control 10250T Series .. Page 3-21 Cover Mounted Control ACM Series .. Page 3-61 Accessories .. Page 16-12 Modifications .. Page 16-40 Technical Data .. Page 18-13 April 20083-64 For more information visit: Contactors & Starters3 Advantage Full Voltage ControlCombination Starters Fusible and Non-fusibleTable 3-52. Class ECA18 Combination Reversing Starter Fusible/Non-fusible Disconnect with CPT For motor full load current (FLA) range of .47A with a to service factor and for motor hp range of 1/4 hp to 2 hp at 460V. Other control power transformer primary and/or secondary voltages, seePage 3-60. All Type 12 enclosures are standardized with external reset. For internal reset, order Mod Code R5. Type 12 enclosure is without safety door interlock. When safety door interlock is required, change seventh character from 8 to 9, ECA1818 EAA would become ECA1819 EAA.


Related search queries