Example: stock market

PROFINET Cabling and Interconnection Technology - Siemens

PROFINET Cabling and Interconnection Technology Guideline for PROFINET Version March 2007 Order No: PROFINET Cabling and Interconnection Version Copyright PNO 2007 - All Rights Reserved Page 2 of 51 pages Document Identification: TC2-06-0010 File name: PN- Cabling -Guide_2252_V200_May07 Prepared by the PROFIBUS Working Group 6 Passive Network Components in the Technical Committee 2 Communication Profiles . The attention of adopters is directed to the possibility that compliance with or adoption of PI (PROFIBUS International) specifications may require use of an invention covered by patent rights. PI shall not be responsible for identifying patents for which a license may be required by any PI specification, or for conducting legal inquiries into the legal validity or scope of those patents that are brought to its attention.

PROFINET Cabling and Interconnection Technology Guideline for PROFINET Version 2.00 March 2007 Order No: 2.252

Tags:

  Profinet

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PROFINET Cabling and Interconnection Technology - Siemens

1 PROFINET Cabling and Interconnection Technology Guideline for PROFINET Version March 2007 Order No: PROFINET Cabling and Interconnection Version Copyright PNO 2007 - All Rights Reserved Page 2 of 51 pages Document Identification: TC2-06-0010 File name: PN- Cabling -Guide_2252_V200_May07 Prepared by the PROFIBUS Working Group 6 Passive Network Components in the Technical Committee 2 Communication Profiles . The attention of adopters is directed to the possibility that compliance with or adoption of PI (PROFIBUS International) specifications may require use of an invention covered by patent rights. PI shall not be responsible for identifying patents for which a license may be required by any PI specification, or for conducting legal inquiries into the legal validity or scope of those patents that are brought to its attention.

2 PI specifications are prospective and advisory only. Prospective users are responsible for protecting themselves against liability for infringement of patents. NOTICE: The information contained in this document is subject to change without notice. The material in this document details a PI specification in accordance with the license and notices set forth on this page. This document does not represent a commitment to implement any portion of this specification in any company's products. WHILE THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE, PI MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS MATERIAL INCLUDING, BUT NOT LIMITED TO ANY WARRANTY OF TITLE OR OWNERSHIP, IMPLIED WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR PARTICULAR PURPOSE OR USE.

3 In no event shall PI be liable for errors contained herein or for indirect, incidental, special, consequential, reliance or cover damages, including loss of profits, revenue, data or use, incurred by any user or any third party. Compliance with this specification does not absolve manufacturers of PROFIBUS or PROFINET equipment, from the requirements of safety and regulatory agencies (T V, BIA, UL, CSA, FCC, IEC, etc.). PROFIBUS and PROFINET logos are registered trade marks. The use is restricted for members of Profibus International. More detailed terms for the use can be found on the web page Please select button "Presentations & logos".

4 In this specification the following key words (in bold text) will be used: may: indicates flexibility of choice with no implied preference. should: indicates flexibility of choice with a strongly preferred implementation. shall: indicates a mandatory requirement. Designers shall implement such mandatory requirements to ensure interoperability and to claim conformance with this specification. Publisher: PROFIBUS Nutzerorganisation Haid-und-Neu-Str. 7 76131 Karlsruhe Germany Phone: +49 (0) 721 / 96 58 590 Fax: +49 (0) 721 / 96 58 589 E-mail: Web site: No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher.

5 PROFINET Cabling and Interconnection Version Copyright PNO 2007 - All Rights Reserved Page 3 of 51 pages Content 1 Management Summary Purpose and Scope of the Document ..5 2 List of Affected Patents / Certification ..5 3 Related Documents and 4 Definitions and Abbreviations ..8 5 Characterisation of the Environmental Conditions in Production and Field Areas ..8 6 Connectors and cables for 7 Procedure for a PROFINET Conformity Certificate .. 11 8 Connectors for PROFINET Data Cabling .. 12 Connectors for Inside Environment (Balanced Cabling ).. 12 Introduction .. 12 The RJ 45 Connector .. 14 Connectors for Outside Environment (Balanced Cabling ).. 15 Introduction .. 15 RJ45 IP67 Connector.

6 17 M12 Connectors .. 18 Connectors for Hybrid Cabling .. 19 Connectors for inside environment (optical fibre).. 20 Introduction .. 20 SC-RJ Connector .. 21 Additonal Fibre connectors for existing installations .. 21 Connectors for outside environment (optical fibre).. 22 Introduction .. 22 SC-RJ Push Pull OF connector .. 23 M12 OF 23 9 Cables for PROFINET Data Cabling .. 24 Balanced 24 Balanced Cables (Type A,B,C) .. 24 Balanced Hybrid Cables (Type B,C).. 27 Optical fibre cables (POF, PCF, multimode, singlemode).. 30 Introduction .. 30 POF and PCF cables .. 31 All-silica multimode optical fibre cables .. 33 All-silica singlemode optical fibre cables .. 35 10 Cord Sets for PROFINET Data Cabling .

7 37 Cord Sets for Balanced 37 Cord Sets for Balanced Type A/B 38 Cord Sets for Balanced Type C Cabling .. 39 Bulkheads for Balanced 39 11 Connectors for 24 Volt Power Supply Cabling .. 40 Push Pull 41 Circular 45 M12 connector .. 45 7/8 inch connector .. 46 12 Connectors for 400 Volt Power Supply Cabling .. 48 13 Application specific Cabling and Interconnection 50 PROFINET Cabling and Interconnection Version Copyright PNO 2007 - All Rights Reserved Page 4 of 51 pages Revision Log Version Date Changes/History TC2WG6 12-Dec-2002 First draft in PI review TC2WG6 31-Aug-2006 Second draft; structure changed, new content TC2WG6 05-Oct-2006 WG TC2WG6 12-Mar-2007 PI Review finished / Change Requests included PROFINET Cabling and Interconnection Version Copyright PNO 2007 - All Rights Reserved Page 5 of 51 pages 1 Management Summary Purpose and Scope of the Document Horizontal communication between automation and field equipment, as well as vertical communication between corporate management level and production, is guaranteed with PROFINET .

8 This guideline describes the passive infrastructure of PROFINET Networks specified in the IEC 61918 (CDV) and IEC 61784-5-3 (CDV) inside and between the automation islands. To fulfil industrial requirements, the industrial installation has to work in industrial environments. This PROFINET guideline describes connectors and cables. The wiring of PROFINET networks has to be realised under system aspects. Compatibility of PROFINET components is necessary to enable easy planning and installation. This Guideline describes the specification for: Connectors, cables, cordsets and other passive network components ( Bulkheads) for PROFINET Data (Optical Fibre and balanced Cabling for PROFINET communication) Connectors and other passive network components ( T-pieces) for PROFINET 24 Volt power supply Connectors and other passive network components ( T-pieces) for PROFINET 400 Volt Power distribution bus This Guideline describes the test specification for.

9 Connectors, cables, cordsets and other passive network components ( bulkhead) for PROFINET (optical fibre and balanced Cabling for PROFINET communication) This PROFINET guideline is intended to be used by: manufacturers of PROFINET cables, connectors and devices. 2 List of Affected Patents / Certification Attention is drawn to the possibility that some of the elements of this guideline may be the subject of patent rights as listed below. The PROFIBUS Nutzerorganisation (PNO) shall not be held responsible for identifying any or all such patent rights. Relevant patents are only those which have an impact on mating compatibility. No patents concerning the mating compatibility: Connectors for PROFINET data: M12 D-coded (IEC 01076-5-101) M12 Optical Fibre connector (IEC 61076-3-101) RJ 45 IP 67 Push Pull connector (IEC PAS 61076-3-117 Variant 14) RJ 45 IP 67 Hybrid connector (IEC 61076-3-106 Variant 5) Connectors for power supply: 24 Volt Push Pull connector 7/8 inch connector M12 A-coded 400 Volt connector (ISO 23570-3) The patent WO 9942877 from company Reichle & De-Massari AG concerns the mating face of the SCRJ FO connector.

10 PROFIBUS& PROFINET International does not guarantee the completeness of this list. Passive components are not certified by PI. PROFINET Cabling and Interconnection Version Copyright PNO 2007 - All Rights Reserved Page 6 of 51 pages 3 Related Documents and References The following documents are indispensable for the use of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-131 International Electrotechnical Vocabulary Part 131: Electric and magnetic circuits. IEC 60050-191 International Electrotechnical Vocabulary Part 191: Dependability and quality of service IEC 60050-195 International Electrotechnical Vocabulary Part 195: Earthing and protection against electric shock IEC 60050-826 International Electrotechnical Vocabulary Part 826: Electrical installations of buildings IEC61158-2: Digital data communications for measurement and control - Fieldbus for use in industrial control systems.


Related search queries