SIPART PS2 ( ) Electropneumatic positionersEdition0 /2017 Compact Operating Instructions Answers for positionersSIPART PS2 ( )Compact Operating and without HARTWith PROFIBUSWith FOUNDATION Fieldbus 05/2017A5E03436620-ACIntroduction1 Safety instructions2 Installing/mounting3 Connecting4 Commissioning5 Service and maintenance6 Technical data7 Appendix8 Legal informationWarning notice systemThis manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol.

SIPART Electropneumatic positioners SIPART PS2 (6DR5...) Compact Operating Instructions 6DR5... With and without HART With PROFIBUS With FOUNDATION Fieldbus

Tags:

  Profibus

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SIPART PS2 (6DR5) - Dyna-Flo

1 SIPART PS2 ( ) Electropneumatic positionersEdition0 /2017 Compact Operating Instructions Answers for positionersSIPART PS2 ( )Compact Operating and without HARTWith PROFIBUSWith FOUNDATION Fieldbus 05/2017A5E03436620-ACIntroduction1 Safety instructions2 Installing/mounting3 Connecting4 Commissioning5 Service and maintenance6 Technical data7 Appendix8 Legal informationWarning notice systemThis manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol.

2 These notices shown below are graded according to the degree of that death or severe personal injury will result if proper precautions are not that death or severe personal injury may result if proper precautions are not that minor personal injury can result if proper precautions are not that property damage can result if proper precautions are not more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property PersonnelThe product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.

3 Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these use of Siemens productsNote the following:WARNINGS iemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with.

4 The information in the relevant documentation must be names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the of LiabilityWe have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent AGDivision Process Industries and DrivesPostfach 48 4890026 N RNBERGGERMANYD ocument order number.

5 A5E03436620 05/2017 Subject to changeCopyright Siemens AG rights reservedTable of of this the and on for symbols on the and with European device in areas subject to explosion safety the linear the part-turn the positioner in a humid subjected to fast acceleration or strong option NCS safety safety notes for PA and PS2 with and without electronics, 2/3/4-wire, with connection type 4-wire, connection diagram (with and without HART).. PS2 with profibus PS2 with FOUNDATION PS2 ( )Compact Operating Instructions, 05/2017, modules 6DR4004-6A and feedback modules 6DR4004-6J and modules 6DR4004-6G and limit switch modules 6DR4004-6K and device version M12 connector in basic device SIPART PS2 with and without connector in basic device SIPART PS2 with profibus connector in basic device SIPART PS2 with FOUNDATION connector for connection of the outputs of the alarm module 6DR4004-6A / -8A (-Z D55).

6 Connector for connecting the outputs of the position feedback module 6DR4004-6J / 8J (-Z D53).. connector for connecting the external position detection system (-Z D54).. connector for connecting the outputs of the SIA module 6DR4004-6G /-8G (-Z D56).. connection for connection for and safety notes for operation with natural of automatic of initialization parameters 1 to air linear linear actuators for initialization of linear initialization of linear part-turn part-turn actuators for initialization of part-turn initialization of part-turn and safety of the with polycarbonate enclosure , aluminum enclosure , and flameproof aluminum enclosure with stainless steel enclosure , flameproof stainless steel enclosure , and narrow aluminum enclosure and repair of contentsSIPART PS2 ( )

7 6 Compact Operating Instructions, 05/2017, device , approvals, explosion gas as actuator PS2 with and without (HART).. PS2 with profibus PA/with FOUNDATION PA Fieldbus feedback limit switch filter NCS modules 6DR4004-5L and position contacting sensors and position detection system C73451-A430-D78 and part sealing plug / thread use of accessory instructions for accessory specifications of accessory drawings of accessory of contentsSIPART PS2 ( )Compact Operating Instructions, 05/2017, A5E03436620-AC7 Table of contentsSIPART PS2 ( )8 Compact Operating Instructions, 05/2017, of this documentationThese instructions are a brief summary of important features, functions and safety information, and contain all information required for safe use of the device.

8 Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of instructions are aimed at persons who install and commission the realize optimum performance from the device, read the complete operating alsoProcess instrumentation catalog ( ) SIPART PS2 product information ( ) compatibilityThe following tables describe compatibility between manual edition, device revision, engineering system and associated editionCommentsDevice revisionCompatible version of device integration package05/2017 New device featuresHARTFW: or higherDevice revision 6 or higherSIMATIC PDM : or higherSIMATIC PDM SP1 EDD.

9 Or higherAMS Device Manager : or higherSITRANS DTM : or higherField communicatorEDD: or higher01/2017 New device featuresHARTFW: Device revision 5 SIMATIC PDM : or higherSIMATIC PDM SP1 EDD: or higherAMS Device Manager : or higherSITRANS DTM : or higherField communicatorEDD: or higherSIPART PS2 ( )Compact Operating Instructions, 05/2017, A5E03436620-AC9 profibus PAManual editionCommentsDevice revisionCompatible version of device integration package05/2017 New device featuresPROFIBUS PAFW: or higherSIMATIC PDM : or higherSIMATIC PDM SP1 EDD: or higherSITRANS DTM : or higherFOUNDATION FieldbusManual editionCommentsDevice revisionCompatible version of device integration package05/2017 New device featuresFOUNDATION FieldbusFW: or higherDevice revision 3 SIMATIC PDM : or higherSIMATIC PDM SP1 EDD: or higherSITRANS DTM : or electropneumatic positioner is used for the continuous control of process valves with pneumatic drives in the following industries.

10 Chemicals Oil and gas Energy production Food and beverages Pulp and paper Water/waste water Pharmaceutical industry Offshore plantsOperate the device according to the specifications in section "Technical data (Page 69)".For additional information, refer to the operating instructions for the the consignment1. Check the packaging and the delivered items for visible Report any claims for damages immediately to the shipping Checking the consignmentSIPART PS2 ( )10 Compact Operating Instructions, 05/2017, A5E03436620-AC3. Retain damaged parts for Check the scope of delivery by comparing your order to the shipping documents for correctness and completeness.