Example: tourism industry

Model 363 Control Valves - Dyna-Flo

Model 363 Control ValvesDyna-Flo Control Valve Services Ltd. Phone: 780 469 4000 Toll Free: 1 866 396 2356 Fax: 780 469 4035 Website: P-363B1118A1 Technical Sales BulletinThe Model 363 Control valve is part of the 360 Series of Control Model 363 is a top guided, unbalanced, single port valve that is suitable for either throttling or on off Control of either liquids or gases. Metal to metal seating is standard on Model 363 Valves with an option for soft standard actuator for the Model 363 Control valve is a Dyna-Flo Model DFC or DFO linear actuators.

Model 363 Control Valves Dyna-Flo Control Valve Services Ltd. Phone: 780 • 469 • 4000 Toll Free: 1 • 866 • 396 • 2356 Fax: 780 • 469 • 4035 Website: www.dynafl o.com

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Model 363 Control Valves - Dyna-Flo

1 Model 363 Control ValvesDyna-Flo Control Valve Services Ltd. Phone: 780 469 4000 Toll Free: 1 866 396 2356 Fax: 780 469 4035 Website: P-363B1118A1 Technical Sales BulletinThe Model 363 Control valve is part of the 360 Series of Control Model 363 is a top guided, unbalanced, single port valve that is suitable for either throttling or on off Control of either liquids or gases. Metal to metal seating is standard on Model 363 Valves with an option for soft standard actuator for the Model 363 Control valve is a Dyna-Flo Model DFC or DFO linear actuators.

2 These heavy-duty actuators are spring return diaphragm style, and can be used for throttling or on-off service, with or without a valve Model 363 Control Valves are manufactured to a high level of quality specifi cations to ensure superior performance and customer 1 Model 363 Control ValveFeaturesVersatilityMultiple port sizes make the 363 an easy valve to reconfi gure when process applications DesignAvailable severe service trim and high temperature confi gurations are well suited to more demanding Temperature OptionThe standard temperature rating of 450oF (232oC) can be extended to 850oF (454oC)

3 , with options available for higher Pressure Drop Capabilities363 Control Valves can shut off against inlet pressures equal to the ASME Gas Service CapabilityThere are standard construction materials that comply with the recommendations of the National Association of Corrosion Engineers (NACE) MR0175/ISO Off CapabilityShut off options are available from ANSI/FCI and IEC 60534-4 Class II to Class Characteristic SelectionsEqual percentage, linear and quick-opening fl ow characteristics MaintenanceAs with all 360 Series Valves , the 363 can be serviced in line with no special tools Control Valve Services Ltd.

4 Phone: 780 469 4000 Toll Free: 1 866 396 2356 Fax: 780 469 4035 Website: Model 363 Control ValvesP-363B1118A2 Technical Sales BulletinSPECIFICATIONSC onfi gurations The Model 363 Control valve is a high capacity single port, globe style valve with a bolted type bonnet. The standard valve plug action is push down to close. Refer to Table 1. Consult your Dyna-Flo sales offi ce for other available confi and Connection Styles (Refer to Table 1) Model : 363 Size: 1/2 , 3/4 , 1 , 1-1/2 , 2 Body: Globe (All Sizes) Rating: ASME 150 / 300 / 600 Connection.

5 RF / RTJ / BWE / SWE / NPT - All SizesMaximum Inlet Pressures and Temperatures Flanged Valves consistent with ASME Class 150, 300, and 600 rating as per ASME , unless further limited by factors in Tables 15, 16, 18, 19, 21, Pressure Drops Maximum pressure drop is the same as maximum inlet pressure unless restricted by the following:Material Temperature Limits: Tables 15, 16, 18, 19, 21, 22 Characteristic and Flow Direction Equal Percentage (Standard) - Flow Up Quick Opening - Flow Up Linear - Flow Up Dyna-Form (Equal Percentage) - Flow Up Dyna-Flute 1 (Equal Percentage) - Flow Up Dyna-Flute 3 (Equal Percentage) - Flow Up Dyna-Flat (Equal Percentage) - Flow UpDimensions Valve and Actuator Outline Dimension Diagram Refer to Figure 2.

6 Valve and Actuator Assembly Dimensions Refer to Tables 5 to 13. Approximate Valve Body and Actuator Weights Refer to Table Body and bonnet material options include: LCC (A350 LF2/A105 Dual Grade optional bonnet material) WCC (A350 LF2/A105 Dual Grade optional bonnet material) WC9 (A182 F22 optional bonnet material) CF8M (A182 F316 optional bonnet material) Refer to Figure 14 for valve construction material temperature limitations. Refer to Table 19 for trim of the Model 363 Control Valves Refer to Figure Diameters and Maximum Valve Plug Travel Refer to Tables 4 to Type and Examples The Standard packing is PTFE V-ring.

7 Live-loaded low emission, graphite, KALREZ and other packing arrangements are available. Refer to Figure Valve Sizing Coeffi cients For standard coeffi cients at maximum travel, refer to Tables 28 & 29. For full list of coeffi cients refer to document more information and other options contact your Dyna-Flo sales offi 363 Control ValvesDyna-Flo Control Valve Services Ltd. Phone: 780 469 4000 Toll Free: 1 866 396 2356 Fax: 780 469 4035 Website: P-363B1118A3 Technical Sales BulletinTable 2 Class VI Valve Shut-off Confi gurationsPort SizeSeatMinimum Seat LoadAllMetal 300 lbs / Lineal InchTable 3 Valve Body and Actuator Assembly Approximate WeightsValve Size(Inch)Body Onlylb (Kg)With Fail ClosedActuatorAssembly Weight lb (Kg)With Fail OpenActuatorAssembly Weightlb (Kg)1/230 (14)DFC - 106978 (26)DFO - 106970 (32)3/430 (14)DFC - 106978 (26)DFO - 106970 (32)130 (14)DFC - 106978 (26)DFO - 106970 (32)1-1/245 (20)DFC - 106993 (42)DFO - 106985 (39)285 (39)

8 DFC - 2069135 (61)DFO - 2069136 (62)DFC - 2105175 (79)DFO - 2105167 (76)DFC - 2156206 (94)DFO - 2156192 (87)Table 1 Standard Shut-Off Classifi cations (in accordance with ANSI/FCI and IEC 60534-4)Valve TrimSeat OptionShut-Off ClassAllMetalStandardClass IV OptionalClass VClass VI(1)Notes: 1 - Refer to Tables 2 & Control Valve Services Ltd. Phone: 780 469 4000 Toll Free: 1 866 396 2356 Fax: 780 469 4035 Website: Model 363 Control ValvesP-363B1118A4 Technical Sales BulletinTable 4 Full Port Valves - Port Diameters, Valve Travel and Mounting ConnectionCharacteristicValve SizePort SizeMax ValveTravelValve Stem and Mounting Connection Diameter inch (mm)StandardOptionalinchinch (mm)inch (mm)StemYoke BossStem Yoke BossEqual Percentage11 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)1-1/21-1/2 ( ) 22 ( )1-1/8 ( )1/2 ( )2-13/16 (71)3/4 ( )3-9/16 (90)Dyna-Form(Equal Percentage)1/21/2 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)

9 3/43/4 ( )Linear11 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)1-1/21-1/2 ( )22 ( )1-1/8 ( )1/2 ( )2-13/16 (71)3/4 ( )3-9/16 (90)Quick Opening1/21 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)3/41 ( )11 ( )1-1/21-1/2 ( )22 ( )1-1/8 ( )1/2 ( )2-13/16 (71)3/4 ( )3-9/16 (90) Model 363 Control ValvesDyna-Flo Control Valve Services Ltd. Phone: 780 469 4000 Toll Free: 1 866 396 2356 Fax: 780 469 4035 Website: P-363B1118A5 Technical Sales BulletinTable 5 Reduced Port Valves - Port Diameters, Valve Travel and Mounting ConnectionCharacteristicValve SizePort SizeMax ValveTravelValve Stem and Mounting Connection Diameter inch (mm)StandardOptionalinchinch (mm)inch (mm)StemYoke BossStem Yoke BossEqual Percentage1-1/21 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)21 ( )3/4 ( )1/2 ( )2-13/16 (71)--Dyna-Form(Equal Percentage)1/21/4 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)3/8 ( )3/41/4 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )

10 2-13/16 (71)3/8 ( )1/2 ( )11/4 ( )3/8 ( )1/2 ( )3/4 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)1-1/221/4 ( )3/8 ( )1/2 ( )3/4 ( )3/4 ( )1/2 ( )2-13/16 (71)--Linear1-1/21 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)21 ( )3/4 ( )1/2 ( )2-13/16 (71)--Quick Opening1-1/21 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)21 ( )3/4 ( )1/2 ( )2-13/16 (71)--Dyna-Flute1 and 3 Flute(Equal Percentage)1/21/4 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)3/411-1/221/4 ( )3/4 ( )1/2 ( )2-13/16 (71)--Dyna-Flat(Equal Percentage)3D25M1D55M1D8M1D1/21/4 ( )3/16 ( )3/4 ( )3/8 ( )2-1/8 (54)1/2 ( )2-13/16 (71)3/411-1/221/4 ( )3/16 ( )3/4 ( )1/2 ( )2-13/16 (71)-- Dyna-Flo Control Valve Services Ltd.