R-Panel/PBR-Panel - Technical Sheet R-PANEL

R-PANELOPEN FRAMING ORSOLID SUBSTRATEARCHITECTURALCOMMERCIALINDUSTRI ALPANEL36"COVERAGEWALLPANELEXPOSEDFASTEN EDu Finishes: SMP, PVDF, and Acrylic-Coated Galvalume u Corrosion Protection: AZ55 per ASTM A 792 for unpainted Galvalume AZ50 per ASTM A 792 for painted Galvalume G90 per ASTM A 653 for Galvanizedu Gauges: 26 ga and 24 ga standard; 22 ga optionalu 36" panel coverage,11/4" rib heightu Panel Length: Minimum: 5'; Maximum: 45' recommendedu Exposed fastened metal building wall systemu Trapezoidal rib on 12" centersPANEL OVERVIEWu UL 2218 Impact Resistance - Class 4u UL 790 Fire Resistance Rating - Class A, per building codeu UL 263 Fire Resistance Rating - per assemblyu UL 580 Uplift Resistance - Class 90u Texas Windstorm Certifiedu Florida Building Code Approved - See Reports for Requirementsu Miami-Dade County, Florida NOA Approved - See Reports for Requirementsu ICC Evaluation Report - ESR-2385 TESTING AND APPROVALSR-PANELPBR-PANEL4"35/16"C15/8"1 1/4"36" Coverage3/4"1"12"4"35/16"C15/8"11/4"36" Coverage3/4"1"12" R-PANEL /PBR-Panel - Technical SheetATTACHMENT DETAILFASTENING PATTERNSSide Lap FastenerPanel FastenerField of PanelEnds of PanelTape Sealant (roof application)Panel FastenerSide Lap FastenerTape Sealant (roof applic)

R-PANEL PBR-PANEL 4" 35 / 16" C 1 / 8" 11/ 4" 36" Coverage 3/ 4" 12" 1" 4" 35/ 16" C 15/ 8" 11/ 4" 36" Coverage 3/ 4" 12" 1" R-Panel/PBR-Panel - Technical Sheet. ATTACHMENT DETAIL FASTENING PATTERNS Side Lap Fastener Panel Fastener Field of Panel Ends of Panel Tape Sealant (roof application) Panel Fastener

Tags:

  Panels, Panel r, R panel pbr

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of R-Panel/PBR-Panel - Technical Sheet R-PANEL

1 R-PANELOPEN FRAMING ORSOLID SUBSTRATEARCHITECTURALCOMMERCIALINDUSTRI ALPANEL36"COVERAGEWALLPANELEXPOSEDFASTEN EDu Finishes: SMP, PVDF, and Acrylic-Coated Galvalume u Corrosion Protection: AZ55 per ASTM A 792 for unpainted Galvalume AZ50 per ASTM A 792 for painted Galvalume G90 per ASTM A 653 for Galvanizedu Gauges: 26 ga and 24 ga standard; 22 ga optionalu 36" panel coverage,11/4" rib heightu Panel Length: Minimum: 5'; Maximum: 45' recommendedu Exposed fastened metal building wall systemu Trapezoidal rib on 12" centersPANEL OVERVIEWu UL 2218 Impact Resistance - Class 4u UL 790 Fire Resistance Rating - Class A, per building codeu UL 263 Fire Resistance Rating - per assemblyu UL 580 Uplift Resistance - Class 90u Texas Windstorm Certifiedu Florida Building Code Approved - See Reports for Requirementsu Miami-Dade County, Florida NOA Approved - See Reports for Requirementsu ICC Evaluation Report - ESR-2385 TESTING AND APPROVALSR-PANELPBR-PANEL4"35/16"C15/8"1 1/4"36" Coverage3/4"1"12"4"35/16"C15/8"11/4"36" Coverage3/4"1"12" R-PANEL /PBR-Panel - Technical SheetATTACHMENT DETAILFASTENING PATTERNSSide Lap FastenerPanel FastenerField of PanelEnds of PanelTape Sealant (roof application)Panel FastenerSide Lap FastenerTape Sealant (roof application)

2 Panel FastenerSide Lap FastenerTape Sealant (roof application)Overdriven fasteners will cause panel should extend 1/2" or more past the insideface of the support panels (ex. 18 ga) or supports (ex. 1/2" steel) mayrequire predrilling of holes for Fastener:Attaching to Wood:#10-14 XL Wood ScrewAttaching to Steel:#12-14 XL Self Drilling ScrewSide Lap Fastener:1/4"-14 x 7/8" XL Stitch ScrewTrim Fastener:1/4"-14 x 7/8" XL Stitch ScrewFASTENER INFORMATION1. Theoretical section properties have been calculated per AISI 2012 'North American Specification for the Design of Cold-Formed Steel Structural Members'.Ixx and Sxx are effective section properties for deflection and Allowable load is calculated in accordance with AISI 2012 specifications considering bending, shear, combined bending and shear and deflection. Allowableload considers the 3 or more equal spans condition.

3 Allowable load does not address web crippling, fasteners, support material or load testing. Panel weightis not Deflection consideration is limited by a maximum deflection ratio of L/180 of Allowable loads do not include a 1/3 stress increase for UNIFORM LIVE LOADS, psfFor various fastener spacings2 3 4 5 6 7 2 3 4 5 6 7 SECTION PROPERTIESB ottom in CompressionWidth Yieldin ksi36 8036 5036 5026Ga2422 Sxxin3/ftIxxin4 in CompressionSxxin3/ftIxxin4/ftInward Load Outward 245 123 73 48 34 23 211 102 60 39 27 317 149 85 55 38 28 299 140 80 52 36 437 201 115 74 51 38 448 207 118 76 53 39 Metal Roofing, - Technical Sheet