- Page 1 -MCE4 Electric Heating / Electric Cooling Packaged UnitsFORM NO. MCE4-100 (07/2018)FEATURES Up to EER cooling efficiency Less than CABINET air leakage Completely self-contained heating and cooling package No outside condensing unit No external REFRIGERANT lines No separate cooling coil Pre-wired and pre-charged Individually metered and controlled Easy service access Louver color options to match building facade Available with optional factory installed Ventilation Air Kit Available with no electric heat Available with optional epoxy coated evaporator and condenser coils Available with optional Miami-Dade rated impact resistant louversREFRIGERANT SYSTEM R410A REFRIGERANT High efficiency compressor Copper tubing with enhanced fin coilsCABINET Fully insulated CABINET for quiet operation Anti-microbial insulation in

- Page 1 - E H E Cooling 4 Pack U R N 4-100 02/2018 FEATURES • Up to 10.0 EER cooling efficiency • Less than 1.4% cabinet air leakage • Completely self-contained heating and cooling package

Tags:

  Feature, System

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of REFRIGERANT SYSTEM CABINET BLOWER …

1 - Page 1 -MCE4 Electric Heating / Electric Cooling Packaged UnitsFORM NO. MCE4-100 (07/2018)FEATURES Up to EER cooling efficiency Less than CABINET air leakage Completely self-contained heating and cooling package No outside condensing unit No external REFRIGERANT lines No separate cooling coil Pre-wired and pre-charged Individually metered and controlled Easy service access Louver color options to match building facade Available with optional factory installed Ventilation Air Kit Available with no electric heat Available with optional epoxy coated evaporator and condenser coils Available with optional Miami-Dade rated impact resistant louversREFRIGERANT SYSTEM R410A REFRIGERANT High efficiency compressor Copper tubing with enhanced fin coilsCABINET Fully insulated CABINET for quiet operation Anti-microbial insulation in

2 All air handling compartmentsBLOWER Four-speed permanently lubricated PSC motor for low maintenance, maximum efficiency and wide airflow range Dynamically balanced BLOWER with resilient motor mounts for smooth and quiet operation Internal washable filterCONTROLS Color coded wiring for easy service Fuse protection on 24V circuit No heat models include 24V output to control external heat sourceINSTALLATION Easy to install and service Louver mounts flush to outside wall Wind load certification up to 186 mphWARRANTY 5 year limited warranty on all partsMCE4 MODEL UNITS MCE4- Page 2 -MODEL NUMBER GUIDER evision CodeP = 208/230 V - 60 Hz - 1 PhFACTORY INSTALLED OPTIONF = Ventilation Air KitC = Coil Corrosion Protection w/ Ventilation Air Kit (9 EER only)

3 SeriesNOMINAL COOLING CAPACITY12 = 12,000 Btu/ hr 18 = 18,000 Btu/ hr 24 = 24,000 Btu/ hr 30 = 30,000 Btu/ hr 36 = 36,000 Btu/ hrFACTORY INSTALLED ELECTRIC HEAT 0 = none 3 = 3 kW 5 = 5 kW 7 = 7 kW 10 = 10 kWM = Magic-PakCE = Cooling/Electric Heat4 = R410a Refrigerant09 = 9 EER10 = 10 EER3 M CE 4- 09 -18 1 F P - 1 MCE4 MODEL UNITS MCE4- Page 3 -ModelVoltage/ Hz/PhaseVoltage RangeMin. Circuit AmpacityMaximum Fuse/HACR BreakerCompressorOutside FanIndoor BlowerR410A Refrig. Charge (oz.)Weight (lbs.)208V230V208V230 VRated Load AmpsLocked Rotor AmpsDia. (in.) Load AmpsRated HPWheel dia. x width (in.)Rated Load AmpsRated HP0 MCE4-09-121*P208-230/60/1197 - x /4442013 MCE4-09-121*P192120255 MCE4-09-121*P242725307 MCE4-09-121*P354040400 MCE4-09-181*P208-230/60/1197 - x /4442043 MCE4-09-181*P192120255 MCE4-09-181*P242725307 MCE4-09-181*P3540404010 MCE4-09-181*P465250600 MCE4-09-241*P208-230/60/1197 - x /4542105 MCE4-09-241*P242730307 MCE4-09-241*P3540404010 MCE4-09-241*P465250600 MCE4-09-301*P208-230/60/1197 - /49 x *P242830307 MCE4-09-301*P3540404010 MCE4-09-301*P465350600 MCE4-09-361*P208-230/60/1197 - /410 x *P272940407 MCE4-09-361*P3641404510 MCE4-09-361*P465450600 MCE4-10-181*P208-230/60/1197 - x /4702223 MCE4-10-181*P192120255 MCE4-10-181*P242730307 MCE4-10-181*P3540404010 MCE4-10-181*P465250600 MCE4-10-241*P208-230/60/1197 - x

4 /4802275 MCE4-10-241*P242730307 MCE4-10-241*P3540404010 MCE-10-241*P465250600 MCE4-10-301*P208-230/60/1197 - /49 x *P242830307 MCE4-10-301*P3540404010 MCE4-10-301*P46535060 ELECTRICAL AND PHYSICAL DATAMCE4 MODEL UNITS MCE4- Page 4 -ModelBlower SpeedCFM @ ext. static pressure - in. with *P MCE4-09-181*P MCE4-09-241*PLow450440425400370 Medium Low700690680650600 Medium High810800790770730 High940920875850810 MCE4-09-301*PLow620600580560535 Medium Low840820785750700 Medium High975940870825760 High10751000930880800 MCE4-09-361*PLow750720680650620 Medium Low1000980950920880 Medium High1100108010501020980 High12701230120011701130 MCE4-10-181*P MCE4-10-241*PLow450440425400370 Medium Low700690680650600 Medium High810800790770730 High940920875850810 MCE4-10-301*PLow630620610580550 Medium Low900890850800750 Medium High107010301000920840 High1220115011001030920 BLOWER PERFORMANCE ELECTRIC HEAT DATAM odelInput Voltage240230208kW/HrBtuhAmpskW/.

5 MODEL UNITS MCE4- Page 5 -PERFORMANCEM odelCoolingCFME lectric Heat @ 240 VBtuhEERS/TkW/HrBtuh0 MCE4-09-121*P12, /AN /A3 MCE4-09-121* ,2005 MCE4-09-121* ,3007 MCE4-09-121*P7. 224,5000 MCE4-09-181*P17, /AN /A3 MCE4-09-181* ,2005 MCE4-09-181* ,3007 MCE4-09-181*P7. 224,50010 MCE4-09-181* ,7000 MCE4-09-241*P22, /AN /A5 MCE4-09-241* ,3007 MCE4-09-241*P7. 224,50010 MCE4-09-241* ,7000 MCE4-09-301*P27, /AN /A5 MCE4-09-301* ,3007 MCE4-09-301*P7. 224,50010 MCE4-09-301* ,7000 MCE4-09-361*P35, /AN /A5 MCE4-09-361* ,3007 MCE4-09-361*P7. 224,50010 MCE4-09-361* ,7000 MCE4-10-181*P18, /AN /A3 MCE4-10-181* ,2005 MCE4-10-181* ,3007 MCE4-10-181*P7. 224,50010 MCE4-10-181* ,7000 MCE4-10-241*P22, /AN /A5 MCE4-10-241* ,3007 MCE4-10-241*P7.

6 224,50010 MCE-10-241* ,7000 MCE4-10-301*P28, /AN /A5 MCE4-10-301* ,3007 MCE4-10-301*P7. 224,50010 MCE4-10-301* ,700 MCE4 MODEL UNITS MCE4- Page 6 -ModelIndoor Temp DB/WB FOutdoor Temperature - DB F658595105115 BtuhS/TkWBtuhS/TkWBtuhS/TkWBtuhS/TkWBtuh S/TkWMCE4-09-121*P85/7213, , , , , , , , , , , , , , , , , , , , *P85/7221, , , , , , , , , , , , , , , , , , , , *P85/7226, , , , , , , , , , , , , , , , , , , , *P85/7233, , , , , , , , , , , , , , , , , , , , *P85/7241, , , , , , , , , , , , , , , , , , , , *P85/7222, , , , , , , , , , , , , , , , , , , , *P85/7228, , , , , , , , , , , , , , , , , , , , *P85/7235, , , , , , , , , , , , , , , , , , , , PERFORMANCE EXTENDED RATINGS MCE4 MODEL UNITS MCE4- Page 7 -ACCESSORIESD escriptionKit NumberWhere UsedPolypropylene Louver Kit (White)ALVRPWHT-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)Polypropylene Louver Kit (White)ALVRPWHT-2 MCE4-09-36 / MCE4-10-30 Polypropylene Louver Kit (Sandstone)ALVRPSAN-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)Polypropylene Louver Kit (Sandstone)ALVRPSAN-2 MCE4-09-36 / MCE4-10-30 Polypropylene Louver Kit (Beige)ALVRPBGE-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)Polypropylene Louver Kit (Beige)ALVRPBGE-2 MCE4-09-36 / MCE4-10-30 Polypropylene Louver Kit (Taupestone)ALVRPTPST-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)Polypropylene Louver Kit (Taupestone)

7 ALVRPTPST-2 MCE4-09-36 / MCE4-10-30 Extruded Aluminum Louver KitALVRAL-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)Extruded Aluminum Louver Kit (Custom Color**)ALVRAL-1 PMCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)Extruded Aluminum Louver KitALVRAL-2 MCE4-09-36 / MCE4-10-30 Extruded Aluminum Louver Kit (Custom Color**)ALVRAL-2 PMCE4-09-36 / MCE4-10-30 Extruded Aluminum Louver Kit (45" height louver)ALVRAL-3 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)Extruded Aluminum Louver Kit (45" height louver)ALVRAL-4 MCE4-09-36 / MCE4-10-30 Extruded Aluminum Louver Kit (Impact Rated)ALVRALC-1 MCE4-09 ( 12, 18, 24, 30) / MCE4-10 (18, 24)Extruded Aluminum Louver Kit (Impact Rated / Custom Color**)ALVRALC-1 PMCE4-09 ( 12, 18, 24, 30) / MCE4-10 (18, 24)Extruded Aluminum Louver Kit (Impact Rated)ALVRALC-2 MCE4-09-36 / MCE4-10-30 Extruded Aluminum Louver Kit (Impact Rated / Custom Color**)ALVRALC-2 PMCE4-09-36 / MCE4-10-30 Wall Sleeve Kit (45 Louver)ASLEEVE-3*MCE4-09 (12, 18)2" Wall Sleeve KitASLEEVE2-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)2" Wall Sleeve KitASLEEVE2-2 MCE4-09-36 / MCE4-10-306" Wall Sleeve KitASLEEVE6-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)6" Wall Sleeve KitASLEEVE6-2 MCE4-09-36 / MCE4-10-306" Wall Sleeve for 45" LouverASLEEVE6-3 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)6" Wall Sleeve for 45" LouverASLEEVE6-4 MCE4-09-36 / MCE4-10-308" Wall Sleeve KitASLEEVE8-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)

8 8" Wall Sleeve KitASLEEVE8-2 MCE4-09-36 / MCE4-10-308" Wall Sleeve for 45" LouverASLEEVE8-3 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)8" Wall Sleeve for 45" LouverASLEEVE8-4 MCE4-09-36 / MCE4-10-3010" Wall Sleeve KitASLEEVE10-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)10" Wall Sleeve KitASLEEVE10-2 MCE4-09-36 / MCE4-10-3010" Wall Sleeve for 45" LouverASLEEVE10-3 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)10" Wall Sleeve for 45" LouverASLEEVE10-4 MCE4-09-36 / MCE4-10-3012" Wall Sleeve KitASLEEVE12-1 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)12" Wall Sleeve KitASLEEVE12-2 MCE4-09-36 / MCE4-10-3012" Wall Sleeve for 45" LouverASLEEVE12-3 MCE4-09 (12, 18, 24, 30) / MCE4-10 (18, 24)12" Wall Sleeve for 45" LouverASLEEVE12-4 MCE4-09-36 / MCE4-10-30 Threaded PVC NippleAADAPTPVC-1 All MCE sWall Sleeve Extension KitASLEEVEXT 4-1, 4-2A SLEEVE WALL KITS (only with 1 & 2, cannot use with 3 & 4)*Thru the wall applications only.

9 ** Customer specified MODEL UNITS MCE4- Page 8 -ACCESSORIES DIMENSIONS (IN.)Kit NumberABCDASLEEVE2-122929-1/829-1/8 ASLEEVE2-2232-3/432-7/829-1/8 ASLEEVE6-162929-1/829-1/8 ASLEEVE6-2632-3/432-7/829-1/8 ASLEEVE6-3*64545-1/829-1/8 ASLEEVE6-4*ASLEEVE8-182929-1/829-1/8 ASLEEVE8-2832-3/432-7/829-1/8 ASLEEVE8-3*84545-1/829-1/8 ASLEEVE8-4*ASLEEVE10-1102929-1/829-1/8 ASLEEVE10-21032-3/432-7/829-1/8 ASLEEVE10-3*104545-1/829-1/8 ASLEEVE10-4*ASLEEVE12-1122929-1/829-1/8 ASLEEVE12-21232-3/432-7/829-1/8 ASLEEVE12-3*124545-1/829-1/8 ASLEEVE12-4*ASLEEVE-3*4545-1/829-1/8*45" wall opening installations only. 6" wall depth or less. Cannot use with MGE Wall ThicknessMCE4 MODEL UNITS MCE4- Page 9 -DIMENSIONS (IN.)

10 ModelABCDEFMCE4-09-121*P43-7/816-7/825-5 /1621-1/218-5/819-1/4 MCE4-09-181*PMCE4-09-241*P47-13/1618-15/ 1627-1/824-3/820-5/821-3/16 MCE4-09-301*PMCE4-09-361*P55-13/1622-13/ 1631-1/824-3/824-3/425-1/16 MCE4-10-181*P47-13/1618-15/1627-1/824-3/ 820-5/821-3/16 MCE4-10-241*PMCE4-10-301*P55-13/1622-13/ 1631-1/824-3/824-3/425-1/16 OUTDOOR SOUND RATINGSM odelSound Rating (dBA)MCE4-09-121*P72 MCE4-09-181*PMCE4-09-241*P74 MCE4-09-301*P76 MCE4-09-361*PMCE4-10-181*P74 MCE4-10-241*P74 MGE4-10-301*P76 RevisionsSectionPage #DescriptionElectrical and Physical Data2added 0 MCE4-10-181P, 0 MCE4-10-241P, 0 MCE4-10-301 PPerformance4added 0 MCE4-10-181P, 0 MCE4-10-241P, 0 MCE4-10-301 PPer ANSI/AHRI Standard 270 MCE4 MODEL UNITS MCE4 FORM NO. MCE4-100 (07/2018)Printed in the 2018 Allied Air Enterprises LLC, a Lennox International Inc.