Rheem Classic Series Heat Pump

Rheem Classic SeriesHeat PumpFORM NO. P11-806 REV. 4RP14**A SeriesEfficiencies: 14 EER HSPFN ominal Sizes 11/2 to 5 Ton [ to kW]Cooling Capacities to kBTU[ to kW] New composite base pan dampens sound, captures louverpanels, eliminates corrosion and reduces number of fastenersneeded Improved tubing design reduces vibration and stress, mak-ing unit quieter and reducing opportunity for leaks Optimized defrost characteristics - decrease defrosting andprovide better home comfort Powder coat paint system for a long lasting professional finish Optimized reversing valve sizing improves shifting perfor-mance for quieter unit operation and increased life of thesystem Enhanced mufflers help to dissipate vibration energy forquieter unit operation Scroll compressor a sound abating feature added to thecompressor significantly reduces noise when system transi-tions in and out of defrost mode Modern cabinet aesthetics increased curb appeal with visu-ally appealing design Curved louver panels provide ultimate coil protection,enhance cabinet strength.

Table of Contents RP14**A Series 2 TABLE OF CONTENTS ... Internal Pressure Relief Valve √ √ √ √ √ √ √ ... Louver removal for coil cleaning is accomplished by removing one screw and lifting the panel out of the composite base pan ().All RP14**A units utilize single

Tags:

  Content, Table of contents, Table, Relief, Removal

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Rheem Classic Series Heat Pump

1 Rheem Classic SeriesHeat PumpFORM NO. P11-806 REV. 4RP14**A SeriesEfficiencies: 14 EER HSPFN ominal Sizes 11/2 to 5 Ton [ to kW]Cooling Capacities to kBTU[ to kW] New composite base pan dampens sound, captures louverpanels, eliminates corrosion and reduces number of fastenersneeded Improved tubing design reduces vibration and stress, mak-ing unit quieter and reducing opportunity for leaks Optimized defrost characteristics - decrease defrosting andprovide better home comfort Powder coat paint system for a long lasting professional finish Optimized reversing valve sizing improves shifting perfor-mance for quieter unit operation and increased life of thesystem Enhanced mufflers help to dissipate vibration energy forquieter unit operation Scroll compressor a sound abating feature added to thecompressor significantly reduces noise when system transi-tions in and out of defrost mode Modern cabinet aesthetics increased curb appeal with visu-ally appealing design Curved louver panels provide ultimate coil protection,enhance cabinet strength.

2 And increased cabinet rigidity Optimized fan orifice optimizes airflow and reduces unitsound Rust resistant screws confirmed through 1500-hour saltspray testing PlusOne Expanded Valve Space 3"-4"-5" service valvespace provides a minimum working area of 27-squareinches for easier access Integrated heat pump lift receptacle allows standard CPVC stands to be inserted into the base PlusOne Triple Service Access 15" wide, industry lead-ing corner service access makes repairs easier and two fastener removable corner allows optimal access tointernal unit components. Individual louver panels come outonce fastener is removed, for faster coil cleaning and easiercabinet reassembly Diagnostic service window with two-fastener opening provides access to the TXV valves and the heat pump revers-ing valve before opening the unit.

3 External gauge port access allows easy connection of low-loss gauge ports Single-row condenser coil makes unit lighter and allows thor-ough coil cleaning to maintain out of the box performance 35% fewer cabinet fasteners and fastener-free base allowfor faster access to internal components and hassle-freepanel removal Service trays hold fasteners or caps during service calls QR code provides technical information on demand forfaster service calls Fan motor harness with extra-long wires allows unit top tobe removed without disconnecting fan wireAirHeat PumpsRP14**A Series Proper sizing and installation of equipment is critical to achieve optimal performance. AirTable of ContentsRP14**A Series2 table OF CONTENTSS tandard Feature table ..3 Available SKUs.

4 3 Features & Benefits ..4-5 Model Number Identification ..6-7 Physical Data ..8 Electrical Data ..8 Accessories ..9 Weighted Sound Power ..9 Thermostats ..9 Unit ..11 Wiring Diagrams ..12 Application Guidelines ..12 Refrigerant Line Size Information ..13-14 Performance Data ..15-21 Guide Specifications ..22 Limited Warranty ..23 AirStandard Feature table /Available SKUsRP14**A Series3 Feature18243036424860R-410a Refrigerant Maximum SEER14141414141414 Maximum Compressor Field Installed Filter Drier Front Seating Service Valves High Pressure Switch Low Pressure Switch Internal Pressure relief Valve Internal Thermal Overload Long Line capability Low Ambient capability with Kit 3-4-5 Service Valve Access Composite Basepan 2 Screw Control Box Access 15" Access to Internal Components Quick release louver panel design No fasteners to remove along bottom Optimized Venturi Airflow Single row condenser coil Powder coated paint Rust resistant screws QR code External

5 Gauge ports Service trays = StandardStandard Feature TableAvailable SKUA vailable ModelsDescriptionRP1418AJ1 NAClassic 1 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60RP1424AJ1 NAClassic 2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60RP1430AJ1 NAClassic 2 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60RP1436AJ1 NAClassic 3 ton 14 SEER Single-Stage Heat Pump-208/230/1/60RP1442AJ1 NAClassic 3 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/1/60RP1448AJ1 NAClassic 4 ton 14 SEER Single-Stage Heat Pump-208/230/1/60RP1460AJ1 NAClassic 5 ton 14 SEER Single-Stage Heat Pump-208/230/1/60RP1436AC1 NAClassic 3 ton 14 SEER Single-Stage Heat Pump-208/230/3/60RP1442AC1 NAClassic 3 1/2 ton 14 SEER Single-Stage Heat Pump-208/230/3/60RP1448AC1 NAClassic 4 ton 14 SEER Single-Stage Heat Pump-208/230/3/60RP1460AC1 NAClassic 5 ton 14 SEER Single-Stage Heat Pump-208/230/3/60RP1436AD1 NAClassic 3 ton 14 SEER Single-Stage Heat Pump-460/3/60RP1442AD1 NAClassic 3 1/2 ton 14 SEER Single-Stage Heat Pump-460/3/60RP1448AD1 NAClassic 4 ton 14 SEER Single-Stage Heat Pump-460/3/60RP1460AD1 NAClassic 5 ton 14 SEER Single-Stage Heat Pump-460/3/60 AirFeatures & BenefitsRP14**A Series4 The RP14**A is our 14 SEER heat pump and is part of theRheem heat pump product line that extends from 14 to 20 SEER.

6 This highly featured and reliable heat pump is designedfor years of reliable, efficient operation when matched withRheem indoor aluminum evaporator coils and furnaces or airhandler units with aluminum unique composite base () reduces sound emission, elimi-nates rattles, significantly reduces fasteners, eliminates corrosionand has integrated brass compressor attachment inserts().Furthermore it has incorporated into the design, water manage-ment features, means for hand placement () for unit maneu-vering, screw trays () and inserts for lifting unit off pad. ()Service Valves () are rigidly mounted in the composite basewith 3" between suction and discharge valves, 4" clearancebelow service valves and a minimum of 5" above the servicevalves, creating industry leading installation ease.

7 The minimum27-square inches around the service valves allows ample roomto remove service valve schrader prior to brazing, plenty ofclearance for easy brazing of the suction and discharge lines toservice valve outlets, easy access and hookup of low loss refrig-erant gauges (), and access to the service valve caps foropening. For applications with long-line lengths up to 250 feettotal equivalent length, up to 200 feet heat pump above evapo-rator, or up to 80 feet evaporator above heat pump, the long-lineinstructions in the installation manual should be are accessed from the corner of the unit by removingonly two fasteners from the control access cover, revealing theindustry s largest 15" wide and 14" tall control area(). With allthis room in the control area the high voltage electrical whip ()can easily be inserted through the right size opening in the bot-tom of the control area.

8 Routing it leads directly to contractorlugs for connection. The low voltage control wires()are easilyconnected to units low voltage wiring. If contactor defrost con-trol or capacitor () needs to be replaced there is more thanadequate space to make the repair. Furthermore, the servicewindow () can be removed to access the TXV and reversingvalve by removing two screws or the entire corner can be removedproviding ultimate access to the TXV or reversing valve.()If in the rare event, greater access is needed to internal compo-nents, such as the compressor, the entire corner of the unit canbe removed along with the top cover assembly to have unprece-dented access to interior of the unit (). Extra wire length isincorporated into each outdoor fan and compressor so top coverand control panel can be positioned next to unit.

9 With minimaleffort the plug can be removed from the compressor and theoutdoor fan wires can be removed from the capacitor to alloweven more uncluttered access to the interior of the unit ().Outdoor coils heights range from as short as 22" to 32", aidingaccess to the compressor. Disassembly to this degree and com-plete reassembly only takes a first time service technician lessthan 10 minutes.()All units utilize strong formed louver panels which provide indus-try leading coil protection. Louver removal for coil cleaning isaccomplished by removing one screw and lifting the panel out of the composite base pan ().All RP14**A units utilize singlerow coils () making cleaning easy and complete, restoring theperformance of the heat pump back to out of the box perfor-mance levels year after year.

10 The outdoor fan motor has sleeve bearings and is inherentlyprotected. The motor is totally enclosed for maximum protectionfrom weather, dust and corrosion. Access to the outdoor fan ismade by removing four fasteners from the fan grille. The outdoorfan can be removed from the fan grille by removing 4 fastenersin the rare case outdoor fan motor fails. Each cabinet has optimized composite () fan orifice assuringefficient and quiet airflow. 12347891012131415561118171619 Introduction to RP14**A Heat Pump14643528119101312 1614181519717 AirFeatures & BenefitsRP14**A Series5 The entire cabinet has powder post paint () achieving 1000hour salt spray rating, allowing the cabinet to retain its aestheticsthroughout its compressors with standard internal pressure relief andinternal thermal overload are used on all capacities assuringlongevity of high efficient and quiet operation for the life of theproduct.


Related search queries