RLV-10 - Regenerative Valve

Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 eaton Brand KWhere measurements are critical request certified drawings. We reserve the right to change specifications without and SpecificationsPerformance data is typical with fluid at 21,8 cST (105 SUS) and 49 C (120 F)Typical application pressure (all ports) 210 bar (3000 psi)Maximum Regenerative flow 57 L/min (15 USgpm) Regeneration diminishes progressively above setting of CBV1-10 Temperature range -40 to 120 C (-40 to 248 F)Fluids All general purpose hydraulic fluids such as: MIL -H-5606, SAE 10, SAE 20, standard Valve package provides means for fast exten-sion of a cylinder at low pres-sure without additional pump flow.

An Eaton Brand EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 K-341.A K Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. 1 6 Port SizeFunction

Tags:

  Eaton, Regenerative

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RLV-10 - Regenerative Valve

1 Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 eaton Brand KWhere measurements are critical request certified drawings. We reserve the right to change specifications without and SpecificationsPerformance data is typical with fluid at 21,8 cST (105 SUS) and 49 C (120 F)Typical application pressure (all ports) 210 bar (3000 psi)Maximum Regenerative flow 57 L/min (15 USgpm) Regeneration diminishes progressively above setting of CBV1-10 Temperature range -40 to 120 C (-40 to 248 F)Fluids All general purpose hydraulic fluids such as: MIL -H-5606, SAE 10, SAE 20, standard Valve package provides means for fast exten-sion of a cylinder at low pres-sure without additional pump flow.

2 This package diverts rod end flow to the head end in order to accelerate the load. When the load induced pres-sure reaches a predetermined level, the Valve closes off. Rod end oil is automatically divert-ed to tank and the full pump pressure is applied, allowing maximum force to develop at lower applying pressure sensitive Regenerative valves consider the following: Rod to diameter ratio. The pressure required to move a cylinder. Losses due to high flows and seal friction may prevent a circuit from staying in kick out of regen-erative operation made via load pressure sensing. Tamper proof and adjustable pres-sure setting options.

3 Provides a smooth transition and decrease of the Regenerative flow through use of a counter-balance Valve . Provides manual override on POC cartridge to lower the load in the event of power loss. Aluminum in-line type DataDescriptionPressure sensitive regenera-tive Valve package with load : Regeneration circuits apply only to single rod cylinders in extension - Regenerative ValveWith load locking 57 L/min (15 USgpm) 210 bar (3000 psi)Pressure DropA - Port CR to CHB - Port VR to CRC - Port VH to CH012 3 45 67 891025507510012515017520022525005 101520251791114 ABPressure - psiPressure - barFlow - USgpmFlow - L/min350303540170 CCHVCVHEATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009 eaton Brand KWhere measurements are critical request certified drawings.

4 We reserve the right to change specifications without FunctionRLV - Pressure sensitive regeneration Valve with load holding check Valve . 2 Size10 - 10 size3 Seal MaterialBlank - Buna-NV - Viton Viton is a registered trademark of DuPontCode P,ort Size Housing Number4G 1/2" BSPP 02-17893410T SAE 10 02-178933 Model Code4 Relief ControlC - CapK - KnobS - Screw 5 Valve Housing Material A - Aluminum 8 Pressure Setting - user requested in 50 PSI stepsExample: 10 - 1000 - 1050 psi 9 Special Features 00 - None(Only required if Valve has special features, omitted if "00".)

5 6 Port Size7 Pressure Range*Note: Code based on pressure in - 60-210 bar (900-3000 psi)*System pressure is limited to 210 bar (3000 psi)Cartridge Description QuantityCBV1-10-*-0-A-30/ Counterbalance Valve 1 DPS2-10-S-F-0-80 Differential pressure sensing 1 POC1-10-S-0-005 Pilot operated check Valve 1566395 Sense check kit 1 Composition ChartDimensionsmm (inch) 1 2 3 4 5 6 7 8 9 Application NotesFormulas to calculate flow in regeneration circuits are.

6 (where Db = Bore Diameter and Dr = Rod Diameter)Combined Flow Db (pump flow plus = X Pump Flowregenerative flow) Dr Regenerative Flow Db - Dr (flow out rod end) = X Pump Flow Dr Retraction Flow Db (flow out of the bind = X Pump Flowend during retraction) Db - Dr Note: This Valve package should not be used as a load holding or load lowering control - Regenerative ValveWith load locking 57 L/min (15 USgpm) 210 bar (3000 psi)RLV10(V)*A** ** / 00** 31,7( )52,5( )DPS2-10-S-F-0-80 CBV1-10-*-0-A-30 Sense CheckPOC1-10-S-0-00568,3( )VHCHCR15 1,6 ( )11 5, 5 ( )36,5 ( )13 8,9 ( )60,1 ( ) 8,73( ) dia.

7 Thru2 ,3 ( ,3( )18 ,2 ( )53,8( )75,4( )31,7( )VRCRCH)