Example: biology

Room Air Conditioners General Wall Mounted …

5 RMG0-02 AGeneral Wall Mounted -50Hz(R410A/R407C) room Air Conditioners2005 Product Data1 Table of contentsPage1. Models Line up ..42. Model Number Features & Benefit ..94. Specifications ..195. Dimensional Drawings ..396. Wiring Diagrams ..507. Refrigerant Cycle Performance Data ..609. Coefficient of Capacity Change ..7910. Operation Limits ..8111. Air Velocity and Temperature Distributions(Reference Data) ..8212. Function of Remote Wall Mounted22005 Product DataTest condition of international standardCLASSIFICATIONKSCISOARIAHAMASSSA 93065151210 C( F) (80) (80) C( F) (67) (67) C( F) (95) (95) C( F) (75) (75) C( F) (70) (70) C( F) (60) (60) C( F) (47) (47) C( F) (43) (43) C( F) (80) (90) C( F) (67) (73) C( F) (115) (110) C( F) (75) (78) C( F) (80) (80)--MaximumWB C( F) (67) (73)--HeatingOutdoorDB C( F) (75) (75)--OperatingWB C( F) (65) (65)--EnclosureIndoorDB C( F) (80) (80) /WB C( F) (75) (75) C( F) (80) (80) C( F) (75) (75) C( F) (67) (70) C( F) (57) (60) C( F) (67) (70) C( F) (57) (60) : Korea StandardAS : Australia StandardISO : International Standard OrganizationSSA : Saudi Arabian StandardARI : Airconditioning and Refrigeration InstituteAHAM.

2005 Product Data 3 General Description Split type of Air Conditioner are known by the category name of Wall Mounted Type of units.These units can be

Tags:

  General, Types, Walls, Mounted, Room, Conditioners, Air conditioners, General wall mounted, Wall mounted type, Room air

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Room Air Conditioners General Wall Mounted …

1 5 RMG0-02 AGeneral Wall Mounted -50Hz(R410A/R407C) room Air Conditioners2005 Product Data1 Table of contentsPage1. Models Line up ..42. Model Number Features & Benefit ..94. Specifications ..195. Dimensional Drawings ..396. Wiring Diagrams ..507. Refrigerant Cycle Performance Data ..609. Coefficient of Capacity Change ..7910. Operation Limits ..8111. Air Velocity and Temperature Distributions(Reference Data) ..8212. Function of Remote Wall Mounted22005 Product DataTest condition of international standardCLASSIFICATIONKSCISOARIAHAMASSSA 93065151210 C( F) (80) (80) C( F) (67) (67) C( F) (95) (95) C( F) (75) (75) C( F) (70) (70) C( F) (60) (60) C( F) (47) (47) C( F) (43) (43) C( F) (80) (90) C( F) (67) (73) C( F) (115) (110) C( F) (75) (78) C( F) (80) (80)--MaximumWB C( F) (67) (73)--HeatingOutdoorDB C( F) (75) (75)--OperatingWB C( F) (65) (65)--EnclosureIndoorDB C( F) (80) (80) /WB C( F) (75) (75) C( F) (80) (80) C( F) (75) (75) C( F) (67) (70) C( F) (57) (60) C( F) (67) (70) C( F) (57) (60) : Korea StandardAS : Australia StandardISO : International Standard OrganizationSSA : Saudi Arabian StandardARI : Airconditioning and Refrigeration InstituteAHAM.

2 Association of Home Appliance Manufacturers2005 Product Data3 General DescriptionSplit type of Air Conditioner are known by the category name of Wall Mounted Type of units can beeasily installed in a small space and have exceptional Cooling for Low-noise operation,itensures a pleasant air conditioned Offers various types of units to its customers to suit for the best application and followingare the important categories offered by LG :1) General Wall Mounted Type Units : Units with the Simplicity in ) Art Cool Units : A new concept of cooling introduced by LG in the field of Air ) Inverter Units : These units are capable of saving the Power consumption with the unique inverter of the Important Features of these units are listed below :1) Providing Health to the Customers : By have the Filters such as Plasma Filter which is capable of removingthe Micro Organisms up to ) Long Term Money Saving : By proving the Features such as Gold Fin, Auto Clean etc.

3 To maintain the sameperformance throughout the ) Best Comfort : With the Features such as Sleep Mode,Timer,Auto Restart Units are available with many standard and optional features which gives our Customers the free choice toselect the unit of their own details refer to the Detailed specification followed after this Electronics Conditioning Division42005 Product Data1. Models Line upGeneral Wall MountedEditionCapacityChassisTypeRefrige rantModel7kC/OR410 ALS-J0760FL(ML)SJH/PR410 ALS-J0762RL(PL)9kC/OR410 ALS-J0962FL(ML)H/PR410 ALS-J0962RL(PL)12kSLC/OR410 ALS-L1262FL(ML)H/PR410 ALS-L1262RL(PL)18kSKC/OR410 ALS-K1863FL(ML)H/PR410 ALS-K1863RL(PL)24kSKC/OR410 ALS-K2460FL(ML)H/PR410 ALS-K2462RL(PL)5kSWH/PR410 AAS-H056 WLA0[S05AH SW0]C/OR410 AAS-C076 QLA0[S07AC SQ0]C/OR410 AAS-C076 QLL0[S07 ACP SQ0]7kH/PR410 AAS-H076 QGA2[G07AH SQ2]H/PR410 AAS-H076 QLA0[S07AH SQ0]SQH/PR410 AAS-H076 QLC0H/PR410 AAS-H076 QLL0[S07 AHP SQ0]C/OR410 AAS-C096 QLA0[S09AC SQ0]C/OR410 AAS-C096 QLL0[S09 ACP SQ0]9kH/PR410 AAS-H096 QGA2[G09AH SQ2]H/PR410 AAS-H096 RLA0[S09AH SR0]H/PR410 AAS-H096 RLC0H/PR410 AAS-H096 RLL0[S09 AHP SR0]#1C/OR410 AAS-C126 RLA0[S12AC SR0]SRC/OR410 AAS-C126 RLM0[S12 ACP SR0]12kH/PR410 AAS-H126 RGA2[G12AH SR2]H/PR410 AAS-H126 RLA0[S12AH SR0]H/PR410 AAS-H126 RLC0H/PR410 AAS-H126 RLM0[S12 AHP SR0]C/OR410 AAS-C186 TLB0[S18AC ST0]C/OR410 AAS-C186 TLA118kC/OR410 AAS-C186 TLB1[S18AC ST1]H/PR410 AAS-H186 TLB0[S18AH ST0]STH/PR410 AAS-H186 TLM0[S18 AHP ST0]C/OR410 AAS-C246 TLB0[S24AC ST0]24kC/OR410 AAS-C246 TLM0[S24 ACP ST0]H/PR410 AAS-H246 TLB0[S24AH ST0]H/PR410 AAS-H246 TLM0[S24 AHP ST0]C/OR410 AAS-C306 MLB0[S30AC SM0]C/OR410 AAS-C306 MLM0[S30 ACP SM0]

4 30kSMH/PR410 AAS-H306 MLB0[S30AH SM0]H/PR410 AAS-H306 MLM0[S30 AHP SM0]C/OR407 CCS-C306 MLB0H/PR407 CCS-H306 MLD036kSNC/OR407 CCS-C366 NLB0H/PR407 CCS-H366 NLD02005 Product Data51. Models Line upEditionCapacityChassisTypeRefrigerantM odel18kSTC/OR410 AAS-C186 TLM1[S18 ACP ST1]H/PR410 AAS-H186 TMA0#224kSTC/OR410 AAS-C246 TMA0H/PR410 AAS-H246 TMA036kSNC/OR410 AAS-C366 NLM0[S36 ACP SN0]H/PR410 AAS-H366 NLM0[S36 AHP SN0]EditionCapacityChassisTypeRefrigeran tModelS6H/PR410 AAS-H0766KA2[G07AH S63]7kS4C/OR410 AAS-C0764DM0[S07 ACP S40]H/PR410 AAS-H0764DM0[S07 AHP S40]S6H/PR410 AAS-H0966KA2[G09AH S63]9kS4C/OR410 AAS-C0964DM0[S09 ACP S40]#3H/PR410 AAS-H0964DM0[S09 AHP S40]SRH/PR410 AAS-H126 RKA2[G12AH SR3]12kS4C/OR410 AAS-C1264DM0[S12 ACP S40]H/PR410 AAS-H1264DM0[S12 AHP S40]18kS5H/PR410 AAS-H1865DM0[S18 AHP S50]24kS5H/PR410 AAS-H2465DM0[S24 AHP S50]EditionCapacityChassisTypeRefrigeran tModel7kS4C/OR410 AAS-C0764DB0[S07AC S40]9kS4C/OR410 AAS-C0964DB0[S09AC S40]C/OR410 AAS-C0964DM0[S09 ACP S40]12kS4C/OR410 AAS-C1264DB0[S12AC S40]C/OR410 AAS-C1264DM0[S12 ACP S40]#4 STH/PR410 AAS-H146 TLM0[S14 AHP ST0]14kH/PR410 AAS-H186 TKA2[G18AH ST3]

5 S5C/OR410 AAS-C1865DB0[S18AC S50]C/OR410 AAS-C1865DM0[S18 ACP S50]STH/PR410 AAS-H246 TKA2[G24AH ST3]24kS5C/OR410 AAS-C2465DB0[S24AC S50]C/OR410 AAS-C2465DM0[S24 ACP S50]62005 Product Data2. Model Number Nomenclature Identification Rule 1:Code TypeCode of ModelMeaning1, 2 Type of AirconditionerA~ZLS: LG Split Type Airconditioner3 ChassisA~ZName of tool of UnitEx. LS-J SJ Chassis4, 5 Capacity0~9 Cooling/Heating CapacityEx. "09" 9,000 Btu/h6 Electric Range1~9 Electric Standard1: 115V/60Hz,6: 220-240V/50Hz2: 220V/60Hz7: 110V, 50/60Hz3: 208-230V/60Hz 8: 380-415V/50Hz5: 200-220V/50Hz9: 380-415V/60Hz7 Function0~9A~Z8 Cooling/HeatingA~ZC: Cooling onlyX: Cooling + E/HeaterH: Heat pumpV: Invert Cooling onlyF: Cooling (R410A)N: Invert Heat pumpR: Heat pump(R410A)D: Gold pin(Outdoor) + Plasma + C/OE: Gold pin(Outdoor)+ Plasma + H/P9 LookA~ZL: LG Brand M: 1st OEM BrandG: 2nd LG BrandN: 2nd OEM Brand123456789-A0 BasicA0 Basic+4 WayB1 Plasma FilterC2 Plasma Filter+4 WayD3 Tele + LEDETele + LCDF5 Plasma F+4 Way+Tele+LCDG6 Low A+A/changeH7 Low A+A/change+Plasma FITele +LED+Plasma FJ8 Internet K94 way+Plasma F+ Oxygen generatorLZ4 way+Soft StartMY4 way+Star Rating NX4 way+Star Rating +Plasma FPW4 way+Soft S+Star Rating QV4 way+Soft S+Star Rating 4+Plasma FRU4 way+Tele+LCDST4 way+Tele+LCD+Soft Start44 way+Mult Tele+LCD+Plasma F8 Wired remote controllerLS J0760 FLNote.

6 Identification Rule 1 is old one. Identification Rule 2 is new Product Data72. Model Number Nomenclature Identification Rule 2:Code TypeCode of ModelMeaning1 Producing Center, A~ZL: Chang-won R22 RefrigerantA: Chang-won R410A2 Product TypeA~ZS: Split Type Air Conditioner3 Cooling/Heating/InverterA~ZC: Cooling onlyH: Heat pumpX: C/O + E/HeaterZ: H/P + E/HeaterV: AC Inverter C/ON: AC Inverter H/PQ: DC Inverter C/OW: DC Inverter H/P4, 5 Capacity0~9 Cooling/Heating CapacityEx. "09" 9,000 Btu/h6 Electric Range1~91: 115V/60Hz,A~Z2: 220V/60Hz3: 208-230V/60Hz 5: 200-220V/50Hz6: 220-240V/50Hz7: 110V, 50/60Hz7 ChassisA~ZName of Chassis of Unit8 LookA~ZLook,Color (Artcool Model)9, 10 FunctionA~Z11 Serial ~9LG Model Development Serial 345678910 ABasicBBasic+4 WayCPlasma FilterDPlasma Filter+4 WayETele+LCDFTele+LCD+Nano plasma+4 WayGNBF F+(A/changeove)+A/clean+Low AHNBF F+(A/changeove)+A/clean+4way+Low AITele+LED+4wayJInternetKPlasma F+4 Way+Oxygen generatorLNBF F+(A/changeove)+A/cleanMNBF F+(A/changeove)+A/clean+4wayNNBF F+(A/changeove)+A/clean+PTCPNBF F+(A/changeove)+Autoclean+4way+PTCQNBF F+(A/changeove)+A/clean+4way+Low A+PTCRN egative ion+A/CleanS(Nano)Plasma+Negative ion+A/CleanT4way+(Nano)Plasma F+Negative ion+A/CleanUNano Plasma F+4 Way+(A/changeove)+A/clean+Oxygen generatorV4way+(Nano)Plasma F+Negative ion+A/Clean+Oxygen generatorWDry contactASC 1 86 TLB1 Note: Identification Rule 1 is old one.

7 Identification Rule 2 is new Product Data2. Model Number Nomenclature Europe Model Number S 0 9 AHPSR0 Development sequenceChassis / Tools of unitW : SW chassis (5K)Q : SQ chassis (7,9K)4: S4 chassis (7,9,12K new)6 : S6 chassis (7,9K G model)R : SR chassis (9,12K)T : ST chassis (18,24K)5 : S5 chassis (18, 24K)M : SM chassis (30K)N : SN chassis (36K)Indicator for unit types : setsN : IndoorU : OutdoorFunction KeyP : Plasma FilterType of OperationC : Cooling OnlyH : Heat PumpType of RefrigerantA : R410aCooling / Heating Capacity (K Btu)Model types : Wall Mounted typeG : Wall Mounted type G model2005 Product Data9 NEO-Plasma Air Purifying SystemLG Electronics unique neo-plasma air purifying system, equipped with 12-level bio-enzyme filters, has further enhanced its sterilization power. While air passes each level of filters, the system can more powerful-ly eliminate household's fine dust and molds, ordinary odors, food smells, and cigar smoke, as well as can destroy bacteria's cell walls to completely kill them.

8 It has a strong sterilization power. Though the industrial development has enhanced people's quality of life and their satisfaction in living, it isincreasingly creating various kinds of pollution, hazardous substances and viruses. In particular, substances (household tick dust, molds, etc.) that create allergies give rise to respiratory diseasesand atopic diseases. Harmful gases, the prime cause of 'new house syndromes, create chronic you ever experienced these symptoms? Whenever seasonschange, You haverunny noseAsthma, andContinuous skin is itchy with-out knowing reasons, You scratch it againand headache,and chronic First antibioticAllergyMold MiteBig dustBlanket dust1 Micro dustDeodorizeMold Pollutant5 Animal smellOdor of food garbageChemical substance2 Fishy smellFoot stinkSmokeOdor of constructioningredientOdor of foodgarbageChemical substance3 InfluenzaVirusAllergyMite43. Features & Benefit102005 Product DataPre FilterThe antibacterial pre-fil-ters primarily removelarge dusts, molds, andquilt PLASMA Air Purifying Systemdeveloped uniquely by LG not onlyremoves microscopic contaminantsand dust, but also removes housemites, pollen, and pet fur to preventallergic diseases like asthma.

9 Nano-size carbon filters catchfine odorous particles again,and doubly and completelyremove odors from the house-hold, thus offering a pleasantenvironment. What is NanoCarbon Ball?Nano(1/1 Bil) ballstructure,consisted of Nanocarbon, is adopted asdeodorizing material first inthe worldNanoParticleNanoParticleNanoParticl eNanoParticleBacteria,VirusBio Active SiteActive StateBacteriolysisRegeneration(Active State)Bacteria SelectiveCaptureDistinctions from Conventional FiltersSimply inactivatebacteriaDestroy bacteria but allowpart of them to surviveThe bio enzyme destroyscell walls and nuclei of bac-teria and allergens, thuscompletely kills bacteriaNano Bio Fusion FilterConventional200~500nmNano CarbonFilterPlasma FilterClean AirThe triple filters consist of a various organic-compound filter to eliminate displeasure and painin the eyes and necks with various organic compounds. It also has a formaldehyde filter to cut off formaldehyde, a prime cause of new-house syn-dromes, and prevents symptoms such as dermatitis, vomiting and pneumonia.

10 And lastly, it has a filter to remove ordinary odors that are causes of migraine and Filter2345 Kitasato Research Center of Environmental Sciences- Inactivating Germs Test Result Performance (No. 16_0113_1,2,3)Japan Food Research Laboratories- Inactivating Germs Test Result Performance (No. 104093863-001,2,3,4,5)- Killing Virus (No. 204031236-001,2,3)Japan Spinners Inspecting Foundation (No. 624217, 019355-13)- NCB Deodorizing 4 Type Test Result 78%~98% SecurityFITI Korea Consumer Science Center (No. 513104-195-A-01)- Killing bacteria, fungi Test Result SecurityITS(International Technical Standard Center) (No. IL26937-A,B)- Inactivating bacteria Test Result SecurityPolluted AirNano bio fusion filters allow their nano-size bio enzymes to directly pene-trate through cell walls of bacteria and allergen to decomposeits cell nuclei and kill conventional methods merely inactivatebacteria or destroy external cell walls , this innovative sterilization methodcan completely decompose bacteria's cell nuclei and kill Bio Fusion Filter3.


Related search queries