Product data Sheet00813-0100-4360, Rev JBMarch 2010 Rosemount Proven field performance and reliability Commitment to continuous improvement Reference accuracy of Two-year stability of Rangeability of 50:1 ContentsSpecifications .. page 3 Product Certifications .. page 9 Dimensional Drawings.. page 11 Ordering Information .. page 17 Rosemount 1151 Configuration data sheet .. page 26 Rosemount 1151 Pressure TransmitterProduct DiscontinuedProduct data Sheet00813-0100-4360, Rev JBMarch 2010 Rosemount 11512 Foundation of Reliable MeasurementWith over eight million transmitters installed worldwide, the Rosemount 1151 continues to offer industry leading value. Changing customer needs and new technologies have driven Product improvements, while advanced manufacturing and testing processes have guaranteed Product quality. The Rosemount 1151 is world-renowned for proven field reliability and field performance and reliabilityFor over 35 years, the 1151 has provided the process control industry with unsurpassed service and reliability in even the harshest of environments.

Product Data Sheet 00813-0100-4360, Rev JB Rosemount 1151 March 2010 2 Foundation of Reliable Measurement With over eight million transmitters installed worldwide, the Rosemount 1151 continues to offer industry leading

Tags:

  Product, Sheet, Data, Pressure, Transmitter, Rosemount, Product data sheet, 1115, Rosemount 1151 pressure transmitter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Rosemount 1151 Pressure Transmitter - Product …

1 Product data Sheet00813-0100-4360, Rev JBMarch 2010 Rosemount Proven field performance and reliability Commitment to continuous improvement Reference accuracy of Two-year stability of Rangeability of 50:1 ContentsSpecifications .. page 3 Product Certifications .. page 9 Dimensional Drawings.. page 11 Ordering Information .. page 17 Rosemount 1151 Configuration data sheet .. page 26 Rosemount 1151 Pressure TransmitterProduct DiscontinuedProduct data Sheet00813-0100-4360, Rev JBMarch 2010 Rosemount 11512 Foundation of Reliable MeasurementWith over eight million transmitters installed worldwide, the Rosemount 1151 continues to offer industry leading value. Changing customer needs and new technologies have driven Product improvements, while advanced manufacturing and testing processes have guaranteed Product quality. The Rosemount 1151 is world-renowned for proven field reliability and field performance and reliabilityFor over 35 years, the 1151 has provided the process control industry with unsurpassed service and reliability in even the harshest of environments.

2 The lasting customer preference results from a combination of advanced technology, and a tradition of field proven to continuous improvementThrough ongoing focus on continuous improvement, reference accuracy has been accomplished as a result of manufacturing and engineering enhancements. In addition, Smart electronics offer rangeability to 50:1, reducing the number of transmitters to specify, procure, and carry in inventory. A modular design allows interchangeable mechanical and electrical components, providing backward and forward flexibilityThe 1151 offers a variety of configurations for differential, gage, absolute and liquid- level measurements including integrated solutions for Pressure , level, and flow. High Pressure models allow static line pressures up to 4500 psi (310 bar). Multiple wetted materials, as well as alternative fill fluids ensure process compatibility. Smart, analog and low-power electronics are available to meet specific application Pressure SolutionsRosemount 3051S Series of InstrumentationHighest performing scalable Pressure , flow and level measurement solutions drive better plant efficiency and more productivity.

3 Innovative features include wireless, advanced diagnostics, and multivariable 3095 Mass Flow TransmitterAccurately measures differential Pressure , static Pressure and process temperature to dynamically calculate fully compensated mass flow. Rosemount 3051 Pressure Transmitter FamilyProven industry standard performance and reliability to increase plant profitability. Includes the most comprehensive offering to meet all application 2051 Pressure TransmitterMeasure Pressure with confidence with a common Product family that includes a wide range of output protocols built on the flexible Coplanar 305, 306 and 304 ManifoldsFactory-assembled, calibrated and seal-tested Transmitter -to-manifold assemblies reduce installation 1199 Diaphragm SealsProvides reliable, remote measurements of process Pressure and protects the Transmitter from hot, corrosive, or viscous fluids. Orifice Plate Primary Element Systems: Rosemount 1495 and 1595 Orifice Plates, 1496 Flange Unions and 1497 Meter SectionsA comprehensive offering of orifice plates, flange unions and meter sections that are easy to specify and order.

4 The 1595 Conditioning Orifice provides superior performance in tight fit Flowmeter Series: Rosemount 3051 SFA ProBar , 3095 MFA Mass ProBar, and 485 The state-of-the-art, fifth generation Rosemount 485 Annubar combined with the 3051S or 3095 MultiVariable Transmitter creates an accurate, repeatable and dependable insertion-type flowmeter. Compact Orifice Flowmeter Series: Rosemount 3051 SFC, 3095 MFC, and 405 Compact Orifice Flowmeters can be installed between existing flanges, up to a Class 600 (PN100) rating. In tight fit applications, a conditioning orifice plate version is available, requiring only two diameters of straight run upstream and two Flowmeter Series: Rosemount 3051 SFP ProPlate, 3095 MFP Mass ProPlate, and 1195 These integral orifice flowmeters eliminate the inaccuracies that become more pronounced in small orifice line installations. The completely assembled, ready to install flowmeters reduce cost and simplify data Sheet00813-0100-4360, Rev JBMarch 20103 Rosemount 1151 SpecificationsPERFORMANCE SPECIFICATIONS(Zero-based calibrated ranges, reference conditions, silicone oil fill, 316 SST isolating diaphragms for HART 4-20 mA protocol.)

5 AccuracyStabilityTemperature EffectLine Pressure EffectOutputModelAccuracy Specification and SpanOutput Code SRanges 3 through 8 for DP and GP; Ranges 4 through 7 for HP of calibrated span between 1:1 to 10:1 of URLS quare Root ModeAll other ranges and transmitters of calibrated span for all spansOutput Codes E, G, L, and MRanges 3 through 5 for DP and GP of calibrated span for all spansP8 Option: Ranges 3 through 8 for DP and GP, all HP and all LT of calibrated span for > 10 inH2 OAll other ranges and transmitters of calibrated span for all spansOutput CodeModelSpecificationSRanges 3-8 of URL for 2 yearsE and GRanges 3-6 All other ranges of URL for 6 months of URL for 6 monthsL and MAll ranges of URL for 6 monthsOutput CodeModelSpecificationSDP/GP Ranges 4-8, HP Ranges 4-8 Zero Error = URL per 100 F (56 C)Total Error = ( URL + of calibrated span) per 100 F; double the effect for other ranges and transmittersE, G, L, and MRanges 4-0 Zero Error = URL per 100 Error = ( URL + of calibrated span) per 100 F; double the effect for Range ErrorSpan ErrorDP Range 4 and 5 of URL for 2,000 psi (13790 kPa), correctable through rezeroing at line Pressure .

6 Correctable to of input reading per 1,000 psi (6895 kPa)DP Range 3 , correctable through rezeroing at line Pressure . Correctable to of input reading per 1,000 psi (6895 kPa)DP Transmitters Ranges 6 - 0 , correctable through rezeroing at line Pressure . Correctable to of input reading per 1,000 psi (6895 kPa)HP Transmitters All Ranges of URL for 4,500 psi (31027 kPa), correctable through rezeroing at line to of input reading per 1,000 psi (6895 kPa). % of calibrated span between 10:1 and 50:1 of +xURLspan-------------- % of calibrated flow span for all spansProduct data Sheet00813-0100-4360, Rev JBMarch 2010 Rosemount 11514 Vibration of URL per g to 200 Hz in any axisPower Supply EffectOutput Codes S, E, and GLess than of output span per voltOutput Codes L, MOutput shift of less than of URL for a 1 V power supply shiftLoad EffectOutput Codes S, E, and GNo load effect other than the change in power supplied to the Codes L, MLess than of URL effect for a change in load from 100k to infinite Circuit Condition (Low Power Only)No damage to the Transmitter will result when the output is shorted to common or to power supply positive (limit 12 V).

7 EMI/RFI EffectOutput shift of less than of span when tested to SAMA PMC from 20 to 1000 MHz and for field strengths up to 30 V/m. Mounting Position EffectZero shift of up to 1 inH2O ( kPa). With liquid level diaphragm in vertical plane, zero shift of up to 1 inH2O ( kPa). With liquid level diaphragm in horizontal plane, zero shift of up to 5 inH2O ( kPa) plus extension length on extended units. All zero shifts can be calibrated out. No effect on SPECIFICATIONSS erviceLiquid, gas, and vapor applicationsRange and Sensor Limits TABLE 1. Transmitter Range Availability by Model (URL = Upper Range Limit) TABLE 2. RangeabilityRange Code1151 Ranges (URL)DPHPGPDP/GP/SealsAPLT330 inH2O ( kPa) NA NANANA4150 inH2O( kPa) 5750 inH2O ( kPa) 6100 psi ( kPa) 7300 psi (2,068 kPa) NA81,000 psi (6,895 kPa) NA NA NA93,000 psi (20,684 kPa)NANA NANANA06,000 psi (41,369 kPa)NANA NANANAO utput CodeMinimum Span(1)(1) Minimum span equals the upper range limit (URL) divided by SpanS (DP and GP, SST, Range 3 8; HP SST, Range 4 7)URL/502 URL(2)(2) Transmitter is capable of measuring from URL to (All Others)URL/50(3)(3) Accuracy specification for calibrated spans from 1:1 to 6:1 of URL URL(2)E, GURL/6 data Sheet00813-0100-4360, Rev JBMarch 20105 Rosemount 1151 OutputsCode S, Smart4 20 mA dc, user selectable for linear or square root output.

8 Digital process variable superimposed on 4 20 mA signal, available to any host that conforms to the HART E, Analog4 20 mA dc, linear with process pressureCode G, Analog10 50 mA dc, linear with process pressureCode L, Low to V dc, linear with process pressureCode M, Low Power1 to 5 V dc, linear with process pressureCurrent Consumption Under Normal Operating Conditions (Low Power Only)Output Code mA dcOutput Code mA dcZero Elevation and SuppressionOutput Codes S, E, and GZero elevation and suppression must be such that the lower range value is greater than or equal to the ( URL) and the upper range value is less than or equal to the (+URL). The calibrated span must be greater than or equal to the minimum span and less than or equal to the maximum Code LZero is adjustable 10% of URL and span is adjustable from 90 to 100% of Code MZero is adjustable 50% of URL and span is adjustable from 50 to 100% of and ZeroOutput Code SSpan and zero may be accessed with local adjustments or remotely through a HART-compatible Codes E, G, L, and MSpan and zero are continuously SupplyExternal power supply required.

9 Transmitter operates according to the following requirements:Output Codes S, E12 to 45 V dc with no loadOutput Code G30 to 85 V dc with no loadOutput Code L5 to 12 V dcOutput Code M8 to 14 V dcWhere: TABLE 3. Output Code AvailabilityCode1151 Output Options/DampingDPHPGPDP/GP/SealsAPLTS4 20 mA, Digital, Smart/Variable E4 20 mA, Linear, Analog/Variable G(1)(1) Not available with CE 50 mA, Linear, Analog/Variable to V, Linear, Low Power/Fixed NAM1 to 5 V, Linear, Low Power/Fixed NACodeVminVmaxRminRmaxRL at Supply Voltage (VS)S(1)(1) A minimum of 250 ohms is required for = (VS 12)E(2)(2) For CSA approvals Vmax = V = 50 (VS 12)G308501100RL= 20 (VS 30)L512 Low Power Minimum Load Impedance: 100 k M814 RmaxRLRminVminVSVmax0 Operating RegionProduct data Sheet00813-0100-4360, Rev JBMarch 2010 Rosemount 11516 Static Pressure LimitsTransmitters operate within specifications between the following limits: Rosemount psia to 2,000 psig ( kPa to 13790 kPa).

10 Rosemount psia to 4,500 psig ( kPa to 31027 kPa). Rosemount 1151AP0 psia to the psia ( kPa) to the 1151 LTLimit is psia ( kPa) to the flange rating or sensor rating, whichever is lower. Overpressure LimitsTransmitters withstand the following limits without damage: Rosemount 1151DP0 psia to 2,000 psig (0 to 13790 kPa). Rosemount 1151HP0 psia to 4,500 psig (0 to 31027 kPa). Rosemount 1151AP0 psia to 2,000 psia (0 to 13790 kPa). Rosemount 1151 GPRanges 3 8: 0 psia to 2,000 psig (0 to 13790 kPa).Range 9: 0 psia to 4,500 psig (31027 kPa).Range 0: 0 psia to 7,500 psig (51710 kPa). Rosemount 1151 LTLimit is 0 psia to the flange rating or sensor rating, whichever is lower. See Table Pressure All Models10,000 psig ( MPa) proof Pressure on the Limits0 to 100% relative humidityVolumetric DisplacementLess than in3 ( cm3)Failure Mode Alarm (Output Code S)If self-diagnosis detects a gross Transmitter failure, the analog signal will be driven below mA or above 21 mA to alert the user.