Example: dental hygienist

SACE Emax 2 - ABB

SACE Emax 2. New low voltage air circuit-breakersTechnical cat. | Ed. | PreliminaryContact usABB SACEA division of ABB BreakersVia Baioni, 3524123 BergamoPhone: +39 035 : +39 035 data and illustrations are not binding. We reserve the right to modify the contents of this document on the basis of technical development of the products, without prior notice. Copyright 2013 ABB. All rights - 03/2013 - - CAL - PreliminaryTechnical catalogue - Edition - PreliminarySACE Emax 2 New low voltage air circuit-breakers 1159372648 ABB catalogue | 1 SDC200023D0201 | 0/1 IndexMain characteristicsThe rangesProtection trip unitsCommunication devices and systemsAccessoriesInstallationOverall dimensionsWiring diagramsOrdering codes 112/04/2013 13:52:5600000000000/2 | 1 SDC200023D0201 | ABB catalogue Chapter 1 Main characteristicsOverview of the SACE Emax 2

The ranges Protection trip units Communication devices and systems Accessories ... Overview of the SACE Emax 2 family, distinctive features of the series, product conformity and service. Chapter 2 The ranges Electrical characteristics of automatic circuit-breakers, switch-disconnectors ... Icu (440Vac) Versione 630 800 1000 1250 1600 2000 2500 ...

Tags:

  Series, Ranges

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SACE Emax 2 - ABB

1 SACE Emax 2. New low voltage air circuit-breakersTechnical cat. | Ed. | PreliminaryContact usABB SACEA division of ABB BreakersVia Baioni, 3524123 BergamoPhone: +39 035 : +39 035 data and illustrations are not binding. We reserve the right to modify the contents of this document on the basis of technical development of the products, without prior notice. Copyright 2013 ABB. All rights - 03/2013 - - CAL - PreliminaryTechnical catalogue - Edition - PreliminarySACE Emax 2 New low voltage air circuit-breakers 1159372648 ABB catalogue | 1 SDC200023D0201 | 0/1 IndexMain characteristicsThe rangesProtection trip unitsCommunication devices and systemsAccessoriesInstallationOverall dimensionsWiring diagramsOrdering codes 112/04/2013 13:52.

2 5600000000000/2 | 1 SDC200023D0201 | ABB catalogue Chapter 1 Main characteristicsOverview of the SACE Emax 2 family, distinctive features of the series , product conformity and 2 The rangesElectrical characteristics of automatic circuit-breakers, switch-disconnectors and derived 3 Protection trip unitsLatest generation Ekip protection trip units for power distribution, generator protection and power 4 Communication devices and systems Supervision, Energy Management and complete integration in the systems with the possibility of communicating with all the main protocols used in the industrial Emax 2 Consultation guideChapter 5 AccessoriesAccessories for SACE Emax 2 circuit-breakers (signaling, control, interlocks, ) and for Ekip protection trip units (connectivity, measurements, protection, etc).

3 Chapter 6 InstallationInstallation and circuit-breaker performance in switchgear, installation environment, degree of protection and limiting curves. Chapter 7 Overall dimensionsOverall dimensions for fixed circuit-breakers, withdrawable circuit-breakers and 8 Wiring diagramsCircuit-breaker and accessories wiring 9 Ordering codesOrdering codes with configuration 212/04/2013 13:52:5711 ABB catalogue | 1 SDC200023D0201 | 1/1 Overview of the SACE Emax 2 familyGuide to selection 1/2 Distinctive features of the series Efficiency 1/3 Control 1/4 Connectivity 1/5 Performance 1/6 Ease of use and safety 1/7 Product conformity Approvals and certifications 1/9 Quality and Sustainability 1/10 ABB SACE Global Service 1/12 Main 112/04/2013 13:52.

4 5711/2 | 1 SDC200023D0201 | ABB catalogue Overview of the SACE Emax 2 familyAutomatic circuit-breakersSwitch-disconnectors Protection trip unitsIcu (440 Vac) Versione 6308001000125016002000250032004000500063 00200X150V100H85S66N50C42 BIcw (1s) controlGeneratorsEkip DipProtection devices--Ekip TouchProtection devices and MeasurementsProtection devices and Measurements-Ekip Hi-TouchProtection devices, Measurements, Network analyzerProtection devices, Measurements, Network analyzer-Ekip G TouchProtection devices and MeasurementsProtection devices and MeasurementsEkip G Hi-TouchProtection devices, Measurements, Network analyzerProtection devices, Measurements, Network analyzerGuide to selectionRanges circuit-breakers @ 690-1150 V AC Switch-disconnectors @ 690-1150 V AC.

5 1000 V DC Sectionalizing truck Earthing switch with making capacity Earthing truck 212/04/2013 13:52:57111 SDC200402F0011 SDC200403F001 ABB catalogue | 1 SDC200023D0201 | 1/3 Distinctive features EfficiencySACE Emax 2 air circuit-breakers have been designed to manage, with maximum efficiency, all low voltage electrical installations: from industrial plants, naval applications, traditional and renewable power generation installations to buildings, shopping centres, data centres and communication networks. Achieving maximum efficiency of an electrical installation in order to reduce consumption and waste requires intelligent management of power supplies and energy use.

6 For this reason, the new technologies used in the SACE Emax 2 circuit-breakers allow the productivity and reliability of installations to be optimized, and at the same time, power consumption to be reduced while fully respecting the environment. SACE Emax 2 is a new series of low voltage air circuit-breakers up to 6300 A. With the ability to efficiently and simply control electrical installations from the traditional to the more complex with minimum impact, the new SACE Emax 2 circuit-breakers represent the evolution of a circuit-breaker into a Power Manager. 312/04/2013 13:52:5811 SDC200405F0011/4 | 1 SDC200023D0201 | ABB catalogue Distinctive features ControlThe exclusive Power Controller function available on the new SACE Emax 2 circuit-breakers monitors the power managed by the circuit-breaker, keeping it below the limit set by the user.

7 As a result of this more effective use, the peak of power consumed can be limited allowing savings on electricity bills. The Power Controller, patented by ABB, disconnects non-priority utilities, such as electric car charging stations, lighting or refrigeration units, during the times when consumption limits need to be respected, and connects them again as soon as it is appropriate. When required, it automatically activates auxiliary power supplies such as generator sets. No monitoring system is required: it is sufficient to set the required load limit on Emax 2, which can control any circuit-breaker located downstream, even if it is not equipped with a measurement function.

8 In installations that are already equipped with energy management systems, the load limit can also be modified remotely. SACE Emax 2 circuit-breakers are equipped with a new generation of protection trip units that are easy to programme and read. The Ekip Touch trip units measure power and energy with precision and save the most recent alarms, events and measurements in order to prevent faults to the installation or trip effectively when necessary. On request, the Network Analyzer function is also available, which controls the quality of absorbed power in real time and with extreme precision.

9 In addition, the innovative Ekip Touch and Hi Touch trip units in the G version include all the functions of generator protection switchgear, offering a safe control solution that is ready to use. No external devices, wiring or inspections are required. 412/04/2013 13:52:59111 SDC200406F001 ABB catalogue | 1 SDC200023D0201 | 1/5 ConnectivitySACE Emax 2 series circuit-breakers can be integrated perfectly into all automation and energy management systems to improve productivity and energy consumption and to carry out remote service. All circuit-breakers can be equipped with communication units available for use with Modbus, Profibus, and DeviceNet protocols as well as the modern Modbus TCP, Profinet and EtherNet IP protocols.

10 The cartridge-type modules can be easily installed directly on the terminal box, even at a later date. Furthermore, the integrated IEC61850 communication module enables connection to automation systems widely used in medium voltage power distribution to create intelligent networks (Smart Grids).Accurate measurements of current, voltage, power and energy are all available by means of the communication modules. The trip units themselves can be used as multimeters that display the measurements available, or the Ekip Multimeter can be connected in the front of the switchgear without the need for external instruments and bulky circuit-breaker functions are also accessible via the Internet, in complete safety, through the Ekip Link switchgear supervision system and the Ekip Control Panel operator panel.


Related search queries