Transcription of SAFETY DATA SHEET: GLYCOL ETHER DB
1 SAFETY data sheet : GLYCOL ETHER DB1. IDENTIFICATIONMSDS Name: Diethylene GLYCOL Monobutyl EtherSynonyms: Butyl Carbitol, GLYCOL ETHER DB, Butyl Di Glycol2. HAZARDS IDENTIFICATIONA ppearance and Odor:Clear. Liquid. Hazards: Irritating to EyesSafety Hazard:Not classified as FLAMMABLE, but will burnHEALTH HAZARD:Skin Contact:May cause moderate irritation to skin. Repeated exposure may cause skin dryness or Contact:Irritating to eyesSigns and Symptoms:Eye irritation signs and symptoms may include a burning sensation,redness, swelling, and/or blurred vision. Skin irritation signs and symptoms may include a burning sensation, redness, swelling,and/or Medical Condition:Pre-existing medical conditions of the following organ(s) or organ system(s) may be aggravated by exposure to this material: SkinEyes3. COMPOSITIONCAS #112-34-5 CHEMICAL NAME:DIETHYLENE GLYCOL MONOBUTYL ETHEREINECS#203-961-6 HAZARD SYMBOLS:XIRISK PHRASES36IN CASE OF TRANSPORTATION EMERGENCY CONTACT:CHEMTREC:(800) 424-9300-----------------------ALL OTHER INQUIRIES:(770) 904-7042 // Rue Cezzan Lavonia, GA 30553 Page: 1 SDS: GLYCOL ETHER DB4.
2 FIRST AID MEASURESG eneral Information: In general no treatment is needed, however obtain medical :Remove to fresh airSkin Contact:Remove contaminated clothing. Flush exposed area with water and follow bywashing with soap if availableEye Contact:Immediately flush eyes with large amounts of water for at least 15 minutes whileholding eyelids open. Transport to the nearest medical facility for :If swallowed, do not induce vomiting: transport to nearest medical facility foradditional treatment. If vomiting occurs spontaneously, keep head below hips toprevent to Physician:consult a poison control center for guidance5. FIRE FIGHTING MEASURESC lear fire area of all non-emergency Point105 C (221 F) - % V(Limits in air)Auto ignition Temperature225 C (437 F)Specific HazardsCarbon monoxide may be evolved if incomplete combustionoccurs. The vapor is heavier than air, spreads along the groundand distant ignition MediaAlcohol-resistant foam, water spray or fog. Dry chemical powder,carbon dioxide, sand or earth may be used for small fires only.
3 Donot discharge extinguishing waters into the aquatic Extinguishing MediaDo not use water jetProtective Equipment for FirefightersWear all protective clothing and self-contained breathingapparatusAdditional AdviseKeep adjacent containers cool by spraying with water6. ACCIDENTAL RELEASE MEASURESO bserve all relevant local and international regulationsPROTECTIVE MEASURESA void contact with spilled or released material. Immediately remove all contaminated clothing. For guidance on selection ofpersonal protective equipment see Section 8 of this MSDS. For guidance on disposal of spilled material see Section 13 of thisMSDS. Shut off leaks, if possible, without personal risk. Remove all possible sources of ignition in the surrounding area. Useappropriate containment to avoid environmental contamination. Prevent from spreading or entering drains, ditches or rivers by using,sand, earth, or other appropriate barriers. Attempt to disperse the vapor or to direct its flow to a safe location for example by usingfog sprays.
4 Take precautionary measures against static discharge. Ensure electrical continuity by bonding and grouping (earthing) allequipment. Monitor area with combustible gas : 2 SDS: GLYCOL ETHER DBCLEAN UP METHODSFor large spills (> 1 drum), transfer by mechanical means, such as vacuum truck, to a salvage tank for recovery or safe disposal. Donot flush away residues with water. Retain as contaminated waste. Allow residues to evaporate or soak up with an appropriateabsorbent material and dispose of safely. Remove contaminated soil and dispose of safely. For small liquid spills (< 1 drum),transfer by mechanical means to a labeled, sealable container for product recovery or safe disposal. Allow residues to evaporate orsoak up with appropriate absorbent material and dispose of safely. Remove contaminated soil and dispose of it ADVISESee Section 13 for information on disposal. Notify authorities if any exposure to the general public or the environment occurs or islikely to HANDLING AND STORAGEG eneral Precautions:Avoid breathing of or contact with material.
5 Only use in well ventilated areas. Wash thoroughly after handling. For guidance onselection of personal protective equipment see Section 8 of the MSDS. Use the information in this data sheet as input to a riskassessment of local circumstances to help determine appropriate controls for safe handling, storage and disposal of this :Handling temerature: AMBIENTS torage:Must be kept inhibited during storage and shipment as material can polymerize. Storage temperature; AMBIENTP roduct TransferKeep containers closed when not in use. Do not use compressed air for filling, discharging or MaterialsFor containers, or container linings use mild steel, or stainless steelContainer AdviseContainers, even those that have been emptied, can still contain explosive vapors. Do not cut, drill, grind, weld, or perform similaroperations on or near InformationGlycol Ethers can be peroxide formers8. EXPOSURE CONTROLS AND PERSONAL PROECTIONO ccupational Exposure LimitsNone Information:Wash hands before eating, drinking, smoking and using ControlsThe level of protection and types of controls necessary will vary depending upon potential exposure conditions.
6 Select controlsbased on a risk assessment of local circumstances. Appropriate measures include: Adequate explosion proof ventilation to controlairborne concentrations below the exposure guidelines/limits. Eye washes and showers for emergency Protective Equipment:Personal protective equipment (PPE) should meet recommended national standards. Check with PPE Protection:If engineering controls do not maintain airborne concentrations to a level which is adequate to protect workers health, selectedrespiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratoryprotective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and a filter suitable for organic gases and vapors [boiling point > 65oC (149oF)] meeting EN141. Where air-filtering respiratorsare unsuitable ( airborne concentrations are high, risk of oxygen deficiency, confined space) use appropriate positive pressurebreathing : 3 SDS: GLYCOL ETHER DBHand ProtectionLonger term protection: PVC.
7 Nitrile rubber. Suitability and durability of a glove is dependent on usage, frequency and durationof contact, chemical resistance of glove material, glove thickness, and dexterity. Always seek advice from glove gloves should be ProtectionChemical splash goggles (chemical mono-goggles)Protective ClothingUse protective clothing which is chemical resistant to this material. SAFETY shoes and boots should also be chemical Exposure ControlsLocal guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing PHYSICAL AND CHEMICAL PROPERTIESAPPEARANCECLEAR LIQUIDODORETHEREALBOILING POINTTYPICAL 225 - 234 C (437-454 FFLASH POINT105 C / 221 F (abel)EXPLOSION/FLAMMABILITY(limits in air) - % (V)AUTO-IGNITION TEMPERATURE225 C / 437 F (ASTM D-2155)VAPOR Pa @ 20 C / 68 FSPECIFIC @ 20 C / 68 FWATER SOLUBILITY@ 20 C / 68 F Completely miscibleVOLATILE ORGANIC CARBON CONTENT100%EVAPORATION RATE (nBuAc=1) (ASTM D 3539, nBuAc=1)10.)
8 STABILITY AND REACTIVITYS tability:Stable under normal conditions of use. Reacts with strong oxidizing to Avoid: High Temperatures. Avoid heat, sparks, open flames, and other ignition to Avoid:Aluminum Strong oxidizing agents. Acids. Strong bases. Salts of strong DecompositionProducts: thermal decomposition is highly dependent on conditions. A complex mixture ofairborne solids, liquids, and gases, including carbon monoxide, carbon dioxide and otherorganic compounds will be evolved when this material undergoes combustion or thermalor oxidative Reactions:HydroscopicPage: 4 SDS: GLYCOL ETHER DB11. TOXICOLOGICAL INFORMATIONB asis for AssessmentInformation given is based on product testingAcute Oral ToxicityLow toxicity: LD50 > 2000 mg/kg, ratAccute Dermal ToxicityLow toxicity: LD50 > 2000 mg/kg, rabbitAcute Inhalation ToxicityLow toxicity: LC50 > near saturated vapor concentration1 hour ratSkin IrritationProlonged/repeated contact may cause defatting of the skinwhich can lead to dermatitisEye IrritationIrritantSensitizationnot a skin sensitizerRepeated Dose ToxicityBlood; causes haemolysis of red blood cells and/oranemia in animals, but not considered relevant for manMutagenicityNot mutagenic12.
9 ECOLOGICAL INFORMATIONACUTE TOXICITYFISHLow toxicity: LC/EC/IC50 >1000 MG/LAQUATIC INVERTEBRATESLow toxicity: LC/EC/IC50 > 1000 MG/LALGAEE xpected to have low toxicity: LC/EC/IC50 > 1000 MG/LMICROORGANISMSLow toxicity: LC/EC/IC50 > 100 MG/LMOBILITYD issolves in waterPersistence/DegradabilityReadily biodegradableOxidizes rapidly by photochemical reactions in airBioaccumulationNot expected to bioaccumulate significantly13. DISPOSAL CONSIDERATIONSMATERIAL DISPOSALR ecover or recycle if possible. It is the responsibility of the waste generator to determine the toxicity and physical properties of thematerial generated to determine the proper waste classification and disposal methods in compliance with applicable DISPOSALD rain container thoroughly. After draining, vent in a safe place away from sparks and fire. Residues may cause an explosion not puncture, cut or weld un-cleaned drums. Send to drum recover or metal LEGISLATIOND isposal should be in accordance with applicable regional, national, and local laws and regulations.
10 Local regulations may be morestringent than regional or national requirements and must be complied : 5 SDS: GLYCOL ETHER DB14. TRANSPORT INFORMATIONUS Department of Transportation Classification (49 CFR)This material is not subject to DOT regulations under 49 CFR parts 171 material is not classified as dangerous under IMDG regulationIATA (Country variations may apply)This material is not classified as dangerous under IATA regulations15. REGULATORY INFORMATIONUS FEDERALTSCACAS# 112-34-5 is listed on the TSCA & SAFETY Reporting ListNone of the chemicals are on the Health & SAFETY Reporting List. Chemical Test RulesCAS# 112-34-5: Testing required by: manufacturers; importers; processo Section 12bCAS# 112-34-5: 4/12bTSCA Significant New Use RuleNone of the chemicals in this material have a SNUR under 302 (RQ)None of the chemicals in this material have an 302 (TPQ)None of the chemicals in this product have a CodesCAS # 112-34-5: acute, chronic, 313 This material contains Diethylene GLYCOL monobutyl ETHER (listed as** undefined **), 100 0%, (CAS# 112-34-5) which is subject to the reporting requirements of Section 313 of SARA Title III and 40 CFRPart Air Act:CAS# 112-34-5 listed as ** no name ** is listed as a hazardous air pollutant (HAP).