Safety data Sheet Section 1: IdentificationProduct identifierProduct Name COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 Synonyms CertainPro Thermal Foil Faced Batts; CertaPro AcoustaBlanket Black; CertaPro AcoustaBoard Black; CertaPro AcoustaTherm Batts (Unfaced & Kraft-Faced); CertaPro Board; CertaPro Partition Batts; CertaPro Thermal Extended Flange Batts (FSK, White PSK Faced); CertaPro Thermal Foil Faced Batts; CertaPro Thermal FSK-25 Faced Batts; CertaPro Thermal Kraft Faced Batts; CertaPro Thermal Kraft Faced Batts product Literature Code: identified uses of the substance or mixture and uses advised againstRecommended use Fiber Glass InsulationDetails of the supplier of the Safety data sheetManufacturer CertainTeed Corporation20 Moores RoadMalvern, PA 19355 United Telephone (General) 610-893-6000 Emergency telephone numberManufacturer 800-424-9300 - CHEMTRECS ection 2: Hazard I

Safety Data Sheet Section 1: Identification Product identifier Product Name • COMMERCIAL INSULATION – SUSTAINABLE INSULATION ™ CT10161-4 ... Details of the supplier of the safety data sheet Manufacturer • CertainTeed Corporation 20 Moores Road Malvern, PA 19355 United States

Tags:

  Product, Identification, Sheet, Data, Section, Data sheet, Insulation, Certainteed, Product identification, Data sheet section 1

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Safety Data Sheet Section 1: Identification - CertainTeed

1 Safety data Sheet Section 1: IdentificationProduct identifierProduct Name COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 Synonyms CertainPro Thermal Foil Faced Batts; CertaPro AcoustaBlanket Black; CertaPro AcoustaBoard Black; CertaPro AcoustaTherm Batts (Unfaced & Kraft-Faced); CertaPro Board; CertaPro Partition Batts; CertaPro Thermal Extended Flange Batts (FSK, White PSK Faced); CertaPro Thermal Foil Faced Batts; CertaPro Thermal FSK-25 Faced Batts; CertaPro Thermal Kraft Faced Batts; CertaPro Thermal Kraft Faced Batts product Literature Code: identified uses of the substance or mixture and uses advised againstRecommended use Fiber Glass InsulationDetails of the supplier of the Safety data sheetManufacturer CertainTeed Corporation20 Moores RoadMalvern, PA 19355 United Telephone (General) 610-893-6000 Emergency telephone numberManufacturer 800-424-9300 - CHEMTRECS ection 2: Hazard IdentificationUnited States (US)According to.

2 OSHA 29 CFR HCSC lassification of the substance or mixtureOSHA HCS 2012 Not classifiedLabel elementsOSHA HCS 2012 Hazard statements No label element(s) requiredOther hazardsOSHA HCS 2012 This product is not considered hazardous under the OSHA 29 CFR Hazard Communication to: WHMIS COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 Preparation Date: 11/September/2012 Preparation Date: 11/September/2012 Preparation Date: 11/September/2012 Preparation Date: 11/September/2012 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Format: GHS Language: English (US)Format: GHS Language: English (US)Format: GHS Language: English (US)Format: GHS Language.

3 English (US)OSHA HCS 2012 OSHA HCS 2012 OSHA HCS 2012 OSHA HCS 2012 Page 1 of 14 Page 1 of 14 Page 1 of 14 Page 1 of 14 Classification of the substance or mixtureWHMIS Not classifiedLabel elementsWHMIS No label element(s) hazardsWHMIS In Canada, the product mentioned above is not considered hazardous under the Workplace Hazardous Materials Information System (WHMIS).Other information Hearing Conservation: Some blowing machines used to install blown-in products create elevated sound levels which may affect workers' hearing. Use of hearing protection by workers exposed above 85 dB(A) as an 8-hour TWA is product may cause temporary irritation to the upper respiratory system, eyes, and inhalation, skin and eye contact as temporary irritation may occur.

4 Wear appropriate personal protective equipment as described in Section 3 - Composition/Information on IngredientsSubstances Material does not meet the criteria of a NameIdentifiers%LD50/LC50 Classifications According to Regulation/DirectiveCommentsGlass, oxide, chemicals CAS:65997-17-378% TO 97% NDAOSHA HCS 2012: Not ClassifiedNDAP etroleum asphalt, oxidized CAS:64742-93-40% TO 17% NDAOSHA HCS 2012: Not ClassifiedThe oxidized asphalt contained in our finished product is a solid form and therefore poses no similar exposure to the heated liquid form during roofing which resulted in IARC classification for this acid, vinyl ester, polymer CAS:9003-20-7< 11% Ingestion/Oral-Rat LD50 >25 g/kgOSHA HCS 2012: Not ClassifiedNDAG reen Binder Proprietary3% TO 9% NDAOSHA HCS 2012: Skin Irrit.

5 2; Skin Sens. 1; Eye Irrit. 2; STOT SE 3: Resp. is cured in final product - no exposure is acid ethenyl ester, polymer with ethene CAS:24937-78-8< 7% Ingestion/Oral-Rat LD50 >2500 mg/kgOSHA HCS 2012: Not ClassifiedNDAM ineral oil, petroleum distillates, solvent-dewaxed heavy paraffinic (severe solvent-refiningand/or hydrotreatment) TO NDAOSHA HCS 2012: Not ClassifiedNDACOMMERCIAL insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 Preparation Date.

6 11/September/2012 Preparation Date: 11/September/2012 Preparation Date: 11/September/2012 Preparation Date: 11/September/2012 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Format: GHS Language: English (US)Format: GHS Language: English (US)Format: GHS Language: English (US)Format: GHS Language: English (US)OSHA HCS 2012 OSHA HCS 2012 OSHA HCS 2012 OSHA HCS 2012 Page 2 of 14 Page 2 of 14 Page 2 of 14 Page 2 of 14 Hydrotreated heavy paraffinic petroleum distillate (highly refined) TO NDAOSHA HCS 2012: Asp. Tox. 1 NDAS ection 4: First-Aid MeasuresDescription of first aid measuresInhalation IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.

7 Administer oxygen if breathing is difficult. Give artificial respiration if victim is not IF ON SKIN: Wash with plenty of soap and water. If skin irritation occurs: Get medical IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical Consult a physician if unusual reaction is noted. product is not intended nor is it likely to be ingested or important symptoms and effects, both acute and delayed Refer to Section 11 - Toxicological of any immediate medical attention and special treatment neededNotes to Physician All treatments should be based on observed signs and symptoms of distress in the patient.

8 Consideration should be given to the possibility that overexposure to materials other than this product may have 5: Fire-Fighting MeasuresExtinguishing mediaSuitable Extinguishing Media LARGE FIRE: Water spray, fog or regular FIRES: Dry chemical, CO2, water spray or regular Extinguishing Media None hazards arising from the substance or mixtureUnusual Fire and Explosion Hazards Material is non-combustible and is not expected to pose a fire or explosion Combustion Products No data availableAdvice for firefighters Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it is not effective in spill situations where direct contact with the substance is chemical protective clothing that is specifically recommended by the manufacturer.

9 It may provide little or no thermal positive pressure self-contained breathing apparatus (SCBA). Section 6 - Accidental Release MeasuresPersonal precautions, protective equipment and emergency proceduresPersonal Precautions Ventilate enclosed areas. Do not walk through spilled material. Wear appropriate protective equipment. Do not touch damaged containers or spilled material unless wearing appropriate protective insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 COMMERCIAL insulation SUSTAINABLE insulation CT10161-4 Preparation Date: 11/September/2012 Preparation Date: 11/September/2012 Preparation Date: 11/September/2012 Preparation Date: 11/September/2012 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Revision Date: 27/April/2016 Format: GHS Language.

10 English (US)Format: GHS Language: English (US)Format: GHS Language: English (US)Format: GHS Language: English (US)OSHA HCS 2012 OSHA HCS 2012 OSHA HCS 2012 OSHA HCS 2012 Page 3 of 14 Page 3 of 14 Page 3 of 14 Page 3 of 14 Emergency Procedures As an immediate precautionary measure, isolate spill or leak area for at least 25 meters (75 feet) in all directions. ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Stay upwind. Keep out of low areas. Keep unauthorized personnel precautions No special precautions and material for containment and cleaning upContainment/Clean-up Measures SMALL SPILLS: Take up with sand or other non-combustible absorbent material and place into containers for later SPILLS: Dike far ahead of spill for later 7 - Handling and StoragePrecautions for safe handlingHandling Do not breathe dust from this material.