Example: quiz answers

Scepter PVC Molded Junction Boxes - ipexna.com

2 Scepter PVC MoldedJunction Boxes ELECTRICAL SYSTEMSTMPVC Molded Junction Boxes 4" to 16"PVC Molded HINGED COVERJUNCTION Boxes 8" to 16"We build tough products for tough environments Technical Catalogue1 The frustrations are gone no more worries aboutpositioning a gasket or over-tightening a coverscrew, and no more loose parts to misplacebefore installation. We ve added features to makethe installation of a Junction box faster and easier;whether locating and aligning conduit entryholes, easily mounting the box to a wall or poleor installing a cover with only one hand, you willappreciate the new design the many labour savingfeatures of the NEW Scepter EASIESTJ unction Box you ll EVER use2 Scepter JBOXFEATURES & BENEFITS.

2 Scepter ® PVC Molded Junction Boxes ELECTRICAL SYSTEMS TM PVC MOLDED JUNCTION BOXES • 4" to 16" PVC MOLDED HINGED COVER JUNCTION BOXES • 8" to 16"

Tags:

  Boxes, Respect, Molded, Junction, Scepter pvc molded junction boxes, 174 pvc molded junction boxes

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Scepter PVC Molded Junction Boxes - ipexna.com

1 2 Scepter PVC MoldedJunction Boxes ELECTRICAL SYSTEMSTMPVC Molded Junction Boxes 4" to 16"PVC Molded HINGED COVERJUNCTION Boxes 8" to 16"We build tough products for tough environments Technical Catalogue1 The frustrations are gone no more worries aboutpositioning a gasket or over-tightening a coverscrew, and no more loose parts to misplacebefore installation. We ve added features to makethe installation of a Junction box faster and easier;whether locating and aligning conduit entryholes, easily mounting the box to a wall or poleor installing a cover with only one hand, you willappreciate the new design the many labour savingfeatures of the NEW Scepter EASIESTJ unction Box you ll EVER use2 Scepter JBOXFEATURES & BENEFITS.

2 3 PRODUCT DIMENSIONS .. 4 Scepter JBOX WITH HINGED COVERFEATURES & BENEFITS .. 5 PRODUCT DIMENSIONS .. 6 7 PERFORMANCE RATINGS .. 7 PHYSICAL PROPERTIES .. 8 10 Sunlight Resistance & WeatheringMaximum Temperature RangeRecommended Operating TemperatureEnclosure Temperature RiseFlame ResistanceImpact ResistanceEMI/RFI ShieldingRelative Thermal IndexChemical ResistanceNEMA RATINGS ..11IP RATINGS ..12 INSTALLATION ..13 18 MountingPole MountingConduit ConnectionsCustom CuttingHinged Cover RemovalTo Re-attach CoverDrilling & CuttingCustom ColorsPainting RecommendationsDrainage HolesGrid LinesSecurity & Restricting AccessBack Panel & Din Rail MountingGrounding & BondingSHORT FORM SPECIFICATIONS .. 183 TMFASTENERS Close by hand tool assist to open 100% non-metallic corrosion resistant material No loose hardware for easy installationLOCK-OUT OPTION Available on sizes 6" to 16" Use a tie-wrap, bolt or padlock for added securityINTEGRATED GASKET Injection Molded and Extruded gaskets permanentlyfixed to the cover no installation required Proprietary gasket material creates a 6P rated enclosure(4" 12") Neoprene gasket material creates a 4X rated enclosure(14" 16")

3 FLAT COVER No ribs offers a flat, smooth surface for mounting ofdevices or labels No engravingsBACK PANEL Designed to fit sizes 6" to 16" Made of 14 gauge carbon steel White epoxy powder-coated finish Easy to cut and drill to mount devicesGRIDLINES Easy reference for drilling knockouts Makes conduit alignment a snap Indicates a drill zone MOUNTING FEET Molded no loose parts to assemble Located on corners out of the way of conduitconnections Flush with the back of the box for close surfacemounting Integrated design of mounting feet offers improvedstrengthPOLE MOUNTING KIT One kit fits 4" to 12" Supplied as a complete kit Works with wood,concrete, steel andcomposite poles Installs on round, square& octagonal poles up to15" diameterFEATURES & BENEFITSThe NEW Scepter JBoxTMis ideally suited forindoor and outdoor use and made to perform inthe most demanding environments.

4 Made of PVCit is extremely durable and resistant to impact in awide range of temperatures and not adverselyaffected by water and chemicals. Built forcorrosive environments, the NEW Scepter JBoxTMis entirely non-metallic, eliminating corrosionconcerns with screws and other metal parts. ListedCSA No. 40 CSA No. 85UL 50 / CSA No. 50E / CSA No. Rated1, 2, 3R, 4, 4X, 6*, 6P*, 12, 13*Applies only to sizes 4" to 12"4 THE NEXT GENERATION Junction BOXSizeInchesPartNumber JBX666 JBX884 JBX887 HDG1G2J1J2M2M1L1W1L2W2KW1M2M1L1HG2G1 DKP1P2N1N2L2W2N1N2 JBX12124 JBX161610L1M1M2W1HG1G2DL2W2N1N2P1P2KP2N1 N2 PRODUCT DIMENSIONSSizeInchesPartNumber JBX12124 JBX12128 277010 compatible back panel sizing.

5 Please refer to pg 165 TMHINGED COVER The new Hinged Cover opens over 214 for completeaccess to installed Boxes Removable for easy mounting of devices in coverFASTENER SYSTEM Features quarter-turn fasteners that are hand-close andtool-assist to openLOCK-OUT OPTION Use a tie-wrap, bolt or padlock for added securityINTEGRATED GASKET Injection Molded and Extruded gaskets permanentlyfixed to the cover no installation required Sizes 8" to 12" feature a proprietary gasket material Sizes 14" to 16" feature a neoprene gasket materialFLAT COVER Easily mount devices in the flat & unobstructed coverMOLDED MOUNTING FEET No loose parts & positioned on the cornersGRIDLINES Provide an easy reference for drilling conduitentry holesMOLDED PANEL MOUNTS Standoffs are Molded -in to accept back panels plusDIN railsBACK PANEL Designed to fit sizes 6" to 16" Made of 14 gauge carbon steel White epoxy powder-coated finish Easy to cut and drill to mount devicesFEATURES & BENEFITSF ully

6 CertifiedCSA No. 50/50 ENEMA Rated1, 2, 3R, 4, 4X, 12, 13 Tested to perform in tough environments, theNEW Scepter JBoxTMHinged Cover junctionbox has added features to make this theeasiest box to use no matter the situation. The new Hinged Cover opens up to 214 and areremovable for complete and easy access tocontrol devices and Scepter JBoxTMHinged Cover is NEMA 3 Rand 4X rated, ideally suited for indoor andoutdoor industrial, MRO and OEM applicaitons,and in wash-down environments. It is 100% non-metallic and includes all the features that usershave come to appreciate in the Scepter NEXT GENERATION Junction BOXSize InchesPart Number JBXH887 1 1 * * ' + 0 0 : / 3 1 . 3 / : 1 0 0 : / * * ' + 1 1 . 1 3 3 3 1 / : JBXH12106 JBXH161610 PRODUCT DIMENSIONSFor compatible back panel sizing, please refer to pg 16 TMAPPLICATION / USEAPPLICATIONSThe Scepter JBoxes are ideal for use wherever PVCconduit and fittings are employed.

7 Scepter JBoxeshave no metallic parts or hardware to be of concernmaking these Boxes ideal for indoor, outdoor, wetlocations and challenging corrosive are well suited for a wide range of applicationssuch as corrosive environments, agricultural, washdown, water and waste-water treatment facilities,marine and car SELECT PVC FOR AN ENCLOSURE?Nonmetallic PVC Boxes /enclosures are lightweight,easily installed and modified, ideal for outdoorexposed to weather applications. They are alsocorrosion resistant and offer a high degree ofresistance to chemical elements. PVC is a costeffective option for enclosures with a proven long lifein indoor and outdoor applications. PVC does notsupport combustion, is self-extinguishing and non-conductive eliminating the danger of can be cut and drilled on sitewithout risk of airborn fibre inhalation associated withfiberglass filled materials.

8 See all 10 reasons in the Scepter PVC conduitbrochure found at RATINGSMax. Temp. Range50 C (122 F)Rec. Operating C to 50 C (-40 F to 122 F)UV and Water ExposureUL 746 CFlame & SmokeUL 94V-O (UL94 Vertical Flame Test)NEMAJBX:1,2,3R,4,4X,6,6P,12,13 JBXH:1,2,3R,4,4X,12,13 Industrial Control PanelsUL 508 AConductorsSuitable for 90 C ratedconductors8 THE NEXT GENERATION Junction BOXPHYSICAL PROPERTIESSUNLIGHT RESISTANCE (UV) & WEATHERINGThe performance of an enclosure during its service lifewill be impacted by environmental conditions. Selectingthe correct material for the application will ensure a longtrouble-free installation. Adverse conditions such ascontinuous direct exposure to sunlight, extremetemperatures and aggressive elements like wind-blownsand will have an impact on the enclosure.

9 Steelenclosures are prone to corrosion when exposed tomoisture and chemical atmospheres, the unprotectedfinish surfaces of Fiberglass enclosures can be adverselyaffected by direct exposure to sunlight (a conditionknown as fiberbloom).PVC provides an excellent balance between materialstrength and environmental performance. The surfaceappearance of Scepter JBoxes are not adversely affectedby exposure to UV, can withstand years of weatherexposure and are particularly well suited for marineareas and salt water TEMPERATURE RANGES cepter JBoxes are acceptable for use in ambienttemperatures as permitted by the CEC. The CEC limitsthe use of PVC in ambient temperatures to 75 C (167 F):RECOMMENDED OPERATING TEMPERATUREThe maximum recommended continuous use temperaturefor the Scepter JBox is 50 C (122 F).

10 Enclosures/ Boxes are designed to provide protectionand enclose electrical/electronic controls, instruments,components and wiring for indoor and outdoorapplications. Ambient temperature may pose a concernfor the enclosure and the products enclosed. The natureof the materials used to manufacture non-metallicenclosures provide a range of operating usetemperatures but what is most important is thetemperature rating of the products contained within. Forexample, if the control equipment within an enclosurehas a maximum operating temperature of 50 C (122OF),having a box that can withstand 130 C (266OF) Operating Temperatures of Non metallic EnclosuresJBX/JBXH-40 C to 50 C(-40 F to 122 F)ABS-18 C to 52 C(0 F to 125 F)Polycarbonate A -40 C to 85 C(-40 F to 185 F)Polycarbonate B -35 C to 82 C(-31 F to 180 F)Polyester A -40 C to 130 C(-40 F to 266 F)Polyester B -40 C to 120 C(-40 F to 248 F)Fiberglass A -40 C to 120 C(-40 F to 250 F)Fiberglass B -35 C to 130 C(-31 F to 266 F)