Class 2510, 2511, 2512, 2601 CONTENTSD escription ..Page Class 2510, 2512 Type F Fractional Horsepower Manual Starters .. 3 Class 2510, 2511, 2512 Type K Manual Switches .. 6 Dimensions for Open Type .. 8 Dimensions for Types F and K .. 9 Class 2510, 2511, 2512 Integral Horsepower Starters Types M and T .. 13 Dimensions for Types M and T .. 15 Accessories and Modifications .. 19 Class 2601 Reversing Drum Switches .. 20 Dimensions for Reversing Drum Switches .. 21 Manual Starters and Switches Selection Guide 1997 Square D All Rights Reserved12/97 Manual Starters and Switches Class 2510, 2512 Type F 3 12/97 1997 Square D All Rights Reserved FRACTIONAL HORSEPOWER MANUAL STARTERS WITH MELTING ALLOY TYPE THERMAL OVERLOAD RELAY Application Data Ty

Class 2510, 2511, 2512, 2601 CONTENTS Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page

Tags:

  2016

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Selection Guide Class 2510, 2511, 2512, 2601

1 Class 2510, 2511, 2512, 2601 CONTENTSD escription ..Page Class 2510, 2512 Type F Fractional Horsepower Manual Starters .. 3 Class 2510, 2511, 2512 Type K Manual Switches .. 6 Dimensions for Open Type .. 8 Dimensions for Types F and K .. 9 Class 2510, 2511, 2512 Integral Horsepower Starters Types M and T .. 13 Dimensions for Types M and T .. 15 Accessories and Modifications .. 19 Class 2601 Reversing Drum Switches .. 20 Dimensions for Reversing Drum Switches .. 21 Manual Starters and Switches Selection Guide 1997 Square D All Rights Reserved12/97 Manual Starters and Switches Class 2510, 2512 Type F 3 12/97 1997 Square D All Rights Reserved FRACTIONAL HORSEPOWER MANUAL STARTERS WITH MELTING ALLOY TYPE THERMAL OVERLOAD RELAY Application Data Type F fractional horsepower starters provide overload protection as well as manual On-Off control for small motors in a variety of industrial and commercial installations.

2 Typical applications include fans, conveyors, pumps, and small machine tools. They are available in one or two pole versions. Both one-pole and two-pole versions are suitable for use with AC single phase motors rated up to 1 horsepower. Two-pole starters may also be used with DC motors rated up to Rating277 VAC maximum (1 or 2 pole)230 VDC maximum (2 pole only)Horsepower RatingsContinuous Current Rating16 AEnclosuresNEMA Type 1 surface mounting enclosures are sheet steel with a thermoplastic wrap-around cover for convenience in wiring.

3 The NEMA Type 1 enclosure is also available in an oversized version that allows more space for wiring. A zinc alloy die casting is used for NEMA Type 4 enclosures, and a cast aluminum enclosure is offered for NEMA Type 3R, 7 & 9 LightRed or green neon pilot light units are available factory installed in NEMA Type 1 surface and flush mounting and NEMA Type 4 enclosures. They are also available as a field modification kit for NEMA Type 1 enclosures and gray flush order number as is for red pilot light; add a G to the number for a green pilot Guard/Lock-OffAn optional handle guard on NEMA Type 1 enclosed starters prevents accidental operation of the toggle operator and allows the toggle operator to be padlocked in either the On or Off position.

4 The handle guard can be factory installed on NEMA Type 1 enclosed starters. It is also available in kit form for field installation on NEMA Type 1 surface and flush mounting enclosures. Standard NEMA Type 4 and NEMA Type 3R, 7 & 9 enclosures include provision for locking in the Off head screw type terminals are suitable for #10 or smaller copper wire, and are accessible from the front. All terminals are clearly types without a pilot light fit standard single gang switch boxes, and can be used with any cover plate having a standard toggle cutout.

5 Single-unit flush mounting types, including those with pilot light, are suitable for wall mounting in a standard switch box or for machine cavity mounting without a with toggle handle or with removable key type operator to discourage unauthorized UnitsStarters will not operate without properly installed thermal units. Install thermal units so that the markings face the front of the FG2 PType FO2 VoltsMaximum HorsepowerAC Single PhaseDC1 Pole2 Pole 2 Pole Only 115 to 23011 3 / 4 27711 Manual Starters and Switches Class 2510, 2512 Type F 1997 Square D All Rights Reserved 4 12/97 Emergency Off ActuatorA toggle operator extender is available for NEMA Type 1 surface-mounted units.

6 The extender has a red vinyl button that provides a fast and easy method for locating and switching the device s toggle operator into the Off position. The Emergency Off Actuator is available in kit form only for field Wiring Diagrams Single-Unit Types ( Class 2510) Type of Type 1 General PurposeEnclosureSurface MountingGeneral Purpose Flush Mounting(Without Pull Box)NEMAType 4 q WatertightandDusttightEnclosureNEMAT ypes 3R,7 & 9 q Class I GroupsB, C, & D & Class II GroupsE, F & GEnclosureOpenTypeNumberofThermalUnitsRe quiredStandard OversizedGrayFlushPlateStandardStainless SteelFlush PlateJumboStainlessSteelFlush Plate Basic Starter Class 2510 Red Pilot Red Pilot Red Pilot Red Pilot Starter with Handle Guard/Lock-Off Class 2510 Toggle1 StandardFG5 FGJ5 Order basic starter plusseparate handle guard Red Pilot Red Pilot q Furnished with one 3 / 4 " pipe tap in bottom (reversible for top feed).

7 To obtain 3 / 4 " pipe tap top and bottom, add suffix letter H to type *2-WIRECONTROLDEVICEOAOHRT2L1T1L2T1T2 MOTORRT2L1T1L2T1T2 MOTOR* Must be rated for motor current2-Pole withSelector Switch2-Pole1-PolePilot light (if used)Pilot light (if used)Pilot light(if used) EnclosedUnitOpenUnitExplosion-Proof Unit File E42243 CCN NLRV File E58760 CCN NPXZFile LR25490 Class 3211 05 File LR25490 Class 3211 05 File LR26817 Class 3218 04 File E42243 CCN NLRV2 Manual Starters and Switches Class 2510, 2512 Type F 5 12/97 1997 Square D All Rights Reserved Duplex Units ( Class 2510)Two Speed Starters ( Class 2512) Type F two-speed manual starters are designed for the control of small single-phase AC motors that have separate windings for high and low speed operation.

8 Two toggle-operated starters are used, with overload protection included for each motor winding. Surface mounting devices, and those with a gray flush plate, utilize a mechanical interlock which allows direct control of the motor by means of the toggle operators. Type 1 General PurposeEnclosure SurfaceMountingGeneral Purpose Flush Mounting (Without Pull Box)NumberofThermalUnitsRequiredGray FlushPlate for Wallor CavityMountingStainless SteelFlush Plate forWall or CavityMounting One Starter in Duplex Enclosure Class 2510 Red Pilot Red Pilot Two Starters in One Enclosure Class 2510 Toggle2 Each Red Pilot Light on EachFG22 PFF22 PFS22P2 Key2 Ea.

9 Str. With Red Pilot Light on EachFG44 PFF44 PFS44P2 Starter and AUTO-OFF-HAND SPDT Selector Switch (AC Only) Class 2510 Red Pilot Red Pilot LightFG72 PFF72 PFS72P1 Key2 With Red Pilot Light Type 1 General PurposeEnclosure SurfaceMountingGeneral Purpose Flush Mounting (Without Pull Box)NumberofThermalUnitsRequiredGray FlushPlate for Wallor CavityMountingStainless SteelFlush Plate forWall or CavityMounting Two Speed StartersReplacement StarterClass 2510 Toggle1 Standard with mechanical interlockFG11FF11 FO1T2 Standard with mechanical interlock and two red pilot lightsFG11 PFF11P FO1PT2 Standard wiith HIGH-OFF-LOW selector switch and two red pilot lights FS101 PFO1PT22 Standard with mechanical interlock.

10 FG22FF22 FO2T2 Standard with mechanical interlock and two red pilot lightsFG22 PFF22P FO2PT2 Standard with HIGH-OFF-LOW selector switch and two red pilot lights FS202 PFO2PT2 Manual Starters and Switches Class 2510, 2511, 2512 Type K 1997 Square D All Rights Reserved 6 12/97 MANUAL SWITCHES TYPE K REVERSING, NON-REVERSING, TWO SPEED Application Data Type K motor starting switches provide manual on-off control of single- or three-phase AC motors, where overload protection is not required or is provided separately.