Example: air traffic controller

SENTRON Switching and Protection Devices – …

siemens LV 1 2008 SENTRON Switching and Protection Devices molded case circuit Breakers16/2 Introduction3VL molded case circuit Breakers3VL molded case circuit Breakersup to 1600 A16/6 General data16/83-pole16/224-pole16/38 Options16/40 Accessories/spare parts3VF2 molded case circuit Breakers3VF2 molded case circuit Breakersup to 100 A16/753-pole, fixed-mounted versions16/754-pole, fixed-mounted versions16/76 Accessories/spare parts siemens AG 2008 SENTRON Switching and Protection Devices molded case circuit BreakersIntroduction16/2 siemens LV 1 200816 Overview Available-- Not available Standard Switching capacity N High Switching capacity H Very high Switching capacity LFor 3VL molded case circuit breakers according to UL 489 see Catalog LV 16.

Siemens LV 1 · 2008 SENTRON Switching and Protection Devices – Molded Case Circuit Breakers 16/2 Introduction 3VL Molded Case Circuit Breakers 3VL Molded Case Circuit Breakers

Tags:

  Devices, Switching, Protection, Case, Circuit, Siemens, Molded, Sentron switching and protection devices, Sentron, Molded case circuit, Sentron switching and protection devices molded case circuit

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SENTRON Switching and Protection Devices – …

1 siemens LV 1 2008 SENTRON Switching and Protection Devices molded case circuit Breakers16/2 Introduction3VL molded case circuit Breakers3VL molded case circuit Breakersup to 1600 A16/6 General data16/83-pole16/224-pole16/38 Options16/40 Accessories/spare parts3VF2 molded case circuit Breakers3VF2 molded case circuit Breakersup to 100 A16/753-pole, fixed-mounted versions16/754-pole, fixed-mounted versions16/76 Accessories/spare parts siemens AG 2008 SENTRON Switching and Protection Devices molded case circuit BreakersIntroduction16/2 siemens LV 1 200816 Overview Available-- Not available Standard Switching capacity N High Switching capacity H Very high Switching capacity LFor 3VL molded case circuit breakers according to UL 489 see Catalog LV 16.

2 1)3VF2 at 40 C ambient )Rated DC voltage applies only for circuit breakers with thermal-magnetic trip case circuit breakers3VL molded case circuit breakers up to 1600 A Rated current Inat 50 C ambient temperature1)A16 to 16026 to 16080 to 250125 to 400 Number of poles34343434 Rated operational voltage UeAC 50/60 Hz DC2)VV6905006905006906006906006906006906 00690600690600 Electronic trip units Thermal-magneticElectronic ETU LCDR eplaceablePROFIBUS module COM10 ------ ------ DimensionsABCD mmmmmmmm10515781107139157811071051758110 7139175811071051758110713917581107139279 102138183279102138 Switching capacity Icu/Ics RMS value according to IEC 60947-2 Standard Switching capacity N3)up to 240 V ACup to 415 V ACup to 440 V ACup to 500/525 V ACup to 690 V ACkAkAkAkAkA65/6540/4025/2018/148/44)65/ 6540/4025/2025/2012/665/6540/4025/2025/2 012/665/6545/4535/2625/2015/8up to 250 V DC5)up to 500 V DC5)

3 Up to 600 V DC5)kAkAkA30/30----32/32----32/32----32/ 32----NEMA breaking capacity6)up to 480 V ACup to 600 V ACkAkA2584)251225123520 High Switching capacity H3)up to 240 V ACup to 415 V ACup to 440 V ACup to 500/525 V ACup to 690 V ACkAkAkAkAkA100/7570/7042/3230/2312/64)1 00/7570/7050/3840/3012/6100/7570/7050/38 40/3012/6100/7570/7050/3840/3015/8up to 250 V DC5)up to 500 V DC5)up to 600 V DC5)kAkAkA30/3030/30--32/3232/32--32/323 2/32--32/3232/32--NEMA breaking capacity6)up to 480 V ACup to 600 V ACkAkA42124)501250125020 Very high Switching capacity L3)up to 240 V ACup to 415 V ACup to 440 V ACup to 500/525 V ACup to 690 V ACkAkAkAkAkA----------200/150100/7575/50 50/3812/6200/150100/7575/5050/3812/6200/ 150100/7575/5050/3815/8up to 250 V DC5)up to 500 V DC5)up to 600 V DC5)kAkAkA------32/3232/3232/3232/3232/3 232/3232/3232/3232/32 NEMA breaking capacity6)up to 480 V ACup to 600 V ACkAkA----751275127520 NSE0_01159 DCAB siemens AG 200816 SENTRON Switching and Protection Devices molded case circuit BreakersIntroduction16/3 siemens LV 1 20083)At 240 V AC, 415 V AC and 525 V AC max.

4 5 % overvoltage, at 440 V AC, 500 V AC and 690 V AC max. 10 % overvoltage, at 240 V DC, 500 V DC and 600 V DC max. 5 % )Rated current In 25 )The maximum permitted DC voltage for each conducting path needs to be taken into account for DC Switching applications, see Technical Information LV 1T, "Configur-ing", " Switching of DC Currents"; time constant t= 15 ms. 6)The NEMA breaking capacity can be found on the rating plate of each IEC circuit breaker. VL630/3VL5VL800/3VL6VL1250/3VL7VL1600/3V L83VF23VL molded case circuit breakers up to 1600 A 3VF2 molded case circuit breakers up to 100 A252 to 630320 to 800400 to 1250640 to 160016 to 100343434343 and 4690600690600690--690--690--690--690--69 0--up to 415.

5 ------1902791021382532791021381904061141 5125340611415122940615220730540615220722 940615220730540615220776/102124687365/65 45/4535/2625/2020/1065/6550/5035/2625/20 20/1065/3550/2535/2625/2020/1065/3550/25 35/2625/2020/1065/3318/9------32/32----- -----------------------2520252025202520- ---100/7570/7050/3840/3030/15100/7570/70 50/3840/3030/15100/5070/3550/3840/3030/1 5100/5070/3550/3840/3030/15----------32/ 3232/32--------------------------5030503 050305030----200/150100/7575/5050/3835/1 7200/150100/7575/5050/3835/17200/100100/ 5075/5050/3835/17200/100100/5075/5050/38 35/17----------32/3232/3232/32---------- --------------6535653565356535---- siemens AG 2008 SENTRON Switching and Protection Devices molded case circuit BreakersIntroduction16/4 siemens LV 1 2008161012101311 NSE0_01888$Withdrawable/plug-in bases (pages 16/49 to 16/54)%Side walls for withdrawable version (pages 16/49 to 16/54)&Phase barriers (pages 16/56 to 16/61)(Flared front busbar connecting bars (pages 16/56 to 16/61))Straight connecting bars (pages 16/56 to 16/61)*Multiple feed-in terminals for Al/Cu (pages 16/58 to 16/61)+Box terminals for Cu (pages 16/56 to 16/61),Extended terminal covers (pages 16/56 to 16/61)-Standard terminal covers (pages 16/56 to 16/61).

6 Masking frames/cover frames for door cut-out (pages 16/70 to 16/73)/Motorized operating mechanisms with spring energy store (pages 16/46 to 16/47)0 Front-operated rotary operating mechanisms (pages 16/43 to 16/48)1 Door-coupling rotary operating mechanisms (pages 16/43 to 16/48)2 SENTRON 3VL circuit breakers (pages 16/8 to 16/39)3 Internal accessories (pages 16/38, 16/40 to 16/41)4 Solid-state overcurrent trip units (pages 16/10 to 16/17, 16/21, 16/28 to 16/33, 16/37)5 Thermal/magnetic overcurrent trip units (pages 16/8 to 16/13, 16/20, 16/22 to 16/29, 16/36)6 RCD modules (page 16/55)7 Rear terminals flat and round (pages 16/56 to 16/61)8 COM10 communications modules to the PROFIBUS DP (page 16/74)9 Function testers for electronic trip units (pages 16/62 to 16/67)

7 siemens AG 200816 SENTRON Switching and Protection Devices molded case circuit BreakersIntroduction16/5 siemens LV 1 200856475647983983212114181716201915 NSE0_01889 siemens AG 20083VL molded case circuit Breakers3VL molded case circuit Breakers up to 1600 AGeneral data16/6 siemens LV 1 200816 Benefits The compact design of the SENTRON 3VL circuit breakers coupled with excellent characteristics fulfills the high demandsof today's electrical distribution systems. These circuit breakers offer a broad product range, improved technology, space savings and easy operation.

8 They are available both in thermal-magnetic (16 A to 630 A)and in electronic versions (63 A to 1600 A).CommunicationThe use of modern communication-capable circuit breakers opens up completely new possibilities in terms of start-up, parameterization, diagnostics, maintenance and operation. This allows many different ways of reducing costs and improving productivity in industrial plants, buildings and infrastructure projects to be achieved: Fast and reliable parameterization Timely information and response can prevent plant stoppages Effective diagnostics managementMeasured values are the basis for efficient load management, for drawing up power demand profiles and for assigning power to cost centers.

9 ApplicationThe different versions of SENTRON 3VL circuit breakers are suitablefor the following applications: Incoming and outgoing circuit breakers in distribution systems Switching and Protection Devices for motors, transformers and capacitors Disconnector units with features for stopping and Switching off in an emergency (main control switches and EMERGENCY-STOP switches) in conjunction with lockable rotary operating mechanisms and terminal SENTRON 3VL circuit breakers are available in the following versions:1. For system Protection (in 3- and 4-pole versions) The overload and short- circuit releases are designed for the Protection of cables, leads and non-motor loads.

10 2. For motor Protection (in 3-pole version) The overload and short- circuit releases are designed for optimized Protection and direct starting of induction squirrel-cagemotors. The circuit breakers for motor Protection are susceptibleto phase failure and feature an adjustable trip class. The electronic trip units operate with a For starter combinations (in 3-pole version) These circuit breakers are used both for short- circuit protectionas well as for isolating functions, which may be required in starter combinations consisting of circuit breakers, overload relays and motor contactors.