Transcription of Series 1 480 VAC - Crydom
1 Ratings from 25 A to 90 A @ 48-530 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriersFor Generation 3 datasheet click here AC or DC control Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free designSeries 1 480 VACPRODUCT SELECTION90 A75 A50 A25 AControl Voltage4-32 VDC D4825D4850D4875D489090-280 VAC A4825A4850A4875A4890 AVAILABLE OPTIONSC ontrol VoltageA: 90-280 VACD: 4-32 VDCR ated Load Current 25: 25 Amps 50: 50 Amps 75: 75 Amps90: 90 AmpsOperatingVoltage48: 48-530 VACT erminationBlank: ScrewF: Quick Connect (1)(Up to 50 Amps)K: Hex standoffs (2)25 AThermal PadBlank: Not IncludedH: Included48 KHSS nubberBlank: Not IncludedS: IncludedSwitching TypeBlank: Zero Voltage Turn-On-10.
2 Instantaneous Turn-On (3)-10 OUTPUT SPECIFICATIONS(4)90 A75 A50 A25 ADescriptionOperating Voltage (47-440Hz) [Vrms] (5)48-53048-53048-53048-530 Transient Overvoltage [Vpk]800800800800 Maximum Off-State Leakage Current @ Rated Voltage [mArms] (6)1111 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/ sec]500 500 500 500 Maximum Load Current [Arms] (2)(7)25507590 Minimum Load Current [mArms]150150150150 Maximum 1 Cycle Surge Current (50/60Hz) [Apk]239/250597/625954/10001145/1200 Maximum On-State Voltage Drop @ Rated Current [Vrms] Resistance Junction to Case (Rjc) [ C/W]Maximum 1/2 Cycle I t for Fusing (50/60Hz) [A sec] Power Factor (at Maximum Load) SPECIFICATIONS(4)DescriptionD48xxA48xxCo ntrol Voltage Range 4-32 VDC90-280 Vrms (60Hz)Maximum Reverse Voltage-32 VDC-Minimum Turn-On VDC(8)90 VrmsMust Turn-Off VDC10 VrmsMinimum Input Current mA Maximum Input Current 12 mA10 mA Nominal Input Impedance Current RegulatedCurrent RegulatedMaximum Turn-On Time [msec]1/2 Cycle(9)20 Maximum Turn-Off Time [msec] 1/2 Cycle30 Required for valid part numberFor options only and not required for valid part numberNot all part number combinations are Crydom Technical support for information onthe availability of a specific part number.
3 *Do not forget to visit us at: 2016 Crydom Inc. Specifications subject to change without MountGENERAL SPECIFICATIONSP arametersDescriptionDielectric Strength, Input/Output/Base (50/60Hz)4000 VrmsMinimum Insulation Resistance (@ 500 VDC)109 OhmMaximum Capacitance, Input/Output8 pFAmbient Operating Temperature Range-40 to 80 CAmbient Storage Temperature Range-40 to 125 CWeight (typical) oz ( g)Housing Material94 V-0 Baseplate MaterialAluminumInput Terminal Screw Torque Range (in-lb/Nm)13-15 Load Terminal Screw Torque Range (in-lb/Nm)18-20 / Mounting Screw Torque Range (in-lb/Nm)18-20 / Terminal Screw Torque Range (in-lb/Nm) (2)w/ K option 8-10 / (4)WIRING DIAGRAMACVLoad(11)1 ( )2 ( )1 OUTPUT2S OLID S T A T E R ELAY4 INPUT34 ( / )3 (+ / )
4 Recommended Wire SizesTerminalsWire Size(Solid / Stranded)Wire Pull-OutStrength (lb)[N]InputOutput24 AWG ( mm2) / [minimum]2 x 12 AWG ( mm2) / [maximum]20 AWG ( mm2) / [minimum]2 x 10 AWG ( mm2) / x 8 AWG ( mm2) / [maximum]10 [ ]90 [400]30 [133]110 [490]90 [400]Input Current vs Input VoltageStandard Regulated DC InputInput Current (mA)2520151050051015202530DC Input Voltage EQUIVALENT CIRCUIT BLOCK DIAGRAMSD iagram: Series 1 DC+DC-DCACT riggerCircuitCurrentLimiterAC3421 (12)Diagram: Series 1 ACACACACT riggerCircuitCurrentLimiterAC3421AC/DCCo nverter (12)Humidity per IEC60068-2-7893% non-condensingMTBF (Mean Time Between Failures) at 40 C ambient temperature (10)11,641,553 hours (1,328 years)MTBF (Mean Time Between Failures) at 60 C ambient temperature (10)7,210,376 hours (823 years)Do not forget to visit us at: 2016 Crydom Inc.
5 Specifications subject to change without MountInput/Output Terminal Screw Thread Size#6-32 UNC / #8-32 UNCMECHANICAL SPECIFICATIONS(4)GENERAL NOTES Screw Termination1 OUTPUT2S OLID S T A T E R [ ] [ ]Mounting Hole/Slot [ ] [ ] [ ] [ ] [ ] [ ] [ ]Hex Standoff Termination ( K Option) [ ] [ ]Mounting Hole/Slot [ ] [ ] [ ] [ ] [ ] [ ] [ ] [ ] (4 places) [ ] (2 places)1 OUTPUT2S OLID S T A T E R ELAY4 INPUT3(2)Quick Connect Termination ( F Option) - Up to 25 Amp (1)1 OUTPUT2S OLID S T A T E R ELAY4 INPUT3 Mounting Hole/Slot [ ] [ ] [ ]Faston Terminal(13) x (2 places) [ ] [ ] [ ] [ ] [ ] [ ]Faston Terminal(13) x (2 places) [ ]Quick Connect Termination ( F Option) - Up to 50 Amp (1)1423S OLID S T A T E R ELAYOUTPUTINPUTM ounting Hole/Slot [ ] [ ] [ ]Faston Terminal(13) x (4 places) [ ] [ ] [ ] [ ] [ ] [ ]Faston Terminal(13) x (2 places) [ ] [ ] [ ](2 places)Tolerances: in / mm All dimensions are in: inches [millimeters]For additional information or specific questions, contact Crydom Technical not forget to visit us at: 2016 Crydom Inc.
6 Specifications subject to change without Mount(1) Single pair (up to 25 A) Double pair* (50 A model only). *Caution: User must connect to both pairs. (2) Option K is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between and inches ( to mm), and loads rated up to 50 Amps. For higher load currents, the K standoff temperature must not exceed 105 C. For additional application assistance please contact Crydom Technical Support.(3) Instantaneous turn-on not recomended for capacitive loads. Use zero turn-on only. (4) All parameters at 25 C unless otherwise specified. (5) For S option, operating voltage frequency is 47-63Hz.(6) For parts with option S maximum leakage current is 10mA. (7) Heat sinking required, see derating curves.
7 (8) Increase minimum voltage by 1V for operations from -20 to -40 C. (9) Turn-on time for Instantaneous turn-on versions is msec (DC Control Models). (10) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (11) Load can be wired to either SSR output terminal 1 or 2. (12) Elective Internal Snubber, S option.(13) Mechanical dimensions vary from G3 models. SURGE CURRENT Current (Amp)Surge Duration (Secs) 25 Current (Amp)Surge Duration (Secs) 50 Current (Amp)Surge Duration (Secs) 75 Current (Amp)Surge Duration (Secs) 90 ANon repetitive peak surge current at Tj initial 40 DERATE INFORMATION252015105203040506070800 Ambient Temperature ( C)Load Current (Amps)25 C/W2 C/W3 C/W5040302010203040506070800 Ambient Temperature ( C)Load Current (Amps)50 C/W1 C/W2 C/W7560453015203040506070800 Ambient Temperature ( C)Load Current (Amps)75 C/W1 C/W809070503010604020203040506070800 Ambient Temperature ( C)Load Current (Amps)90 C/W1 C/WDo not forget to visit us at: 2016 Crydom Inc.
8 Specifications subject to change without MountAGENCY APPROVALSEN60950 : Meets the requirements of : 1,7: : : : : :Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge Level 3 IEC 61000-4-4 : Electrically Fast Transients Level 3 IEC 61000-4-5 : Electrical Surges Level 3 IEC 60068-2-6 : Vibration and mm Amplitude over 10-55 HzIEC 60068-2-27 : Shock Resistance 15g/11msE116949 LR81689 10143 UG ACCESORIESR ecommended AccessoriesCoverHardwareKitHeat SinkPart Resistance[ C/W]Lug TerminalThermal PadKS101HK1HK4 TRM1 TRM6 HSP-1 HSP-2HS501 DRHS301 / HS301 DRHS251HS202 / HS202 DRHS201 / HS201 DRHS172HS151 / HS151 DRHS122 / HS122 DRHS103 / Rev. 041116 Part number: KS101 Clear plastic cover compatible with all new S1 designs.
9 Safety covers provide added protection from electric shock when installing or checking CoverHardware KitPart number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug Accessories!Protective Cover & Hardware KitsDo not forget to visit us at: 2016 Crydom Inc. Specifications subject to change without MountDo not forget to visit us at: 2016 Crydom Inc. Specifications subject to change without MountDANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSIO N, OR ARC FLASH. Di sconnect all power b efore insta lling or working with th is equipment. Verify all connecti ons and r eplace a ll covers b efore tu rning o n t o f ollow these in structio ns will result in d eath or s erio us inju ry.
10 RIESGO DE DESCARGA ELECTRICA O EXPLOSIO N. Desconecta r to dos los suministr os d e energia a e ste equipo antes de tr abajar con e ste equipo. Verificar todas las conexiones y colocar todas las tapas antes de energizer el in cumplimie nto de e stas in struccio nes puede p rovocar la muerte o le sio nes s eria DE DESCHARGE ELECTRIQUE OU EXPLOSION Ete indre to ute s les sources d' nergie de cet a ppareil avant de tr availler dessus d e c et appareil V rifier tousconnections, etremettre tous couverts enolace avant demettre sousDe n on-suiv i de ces instructio ns provoquera la mort o u d es l sio ns s rieuses s EIN ES ELEKTRISCHEN SCHLAGES ODER EINER EXPLOSIO N. Ste llen Sie jeglichen Str om a b, d er dieses G er t versorgt, bevor S ie an dem Ger t Arbeiten durchf hren Vor d em Dr ehen auf Energie alle Anschl sse berpr fen und alle Abdeckungen ssung die ser Anweisungen k nnen z um Tode o der z u schwerenVerle tzungen f DI SCOSSA ELETTRICA O DELL E SPLOSIONE.