Example: biology

Smart-Enabled, 2-Wire Transmitter - Emerson

Instruction ManualLIQ-MAN-1066 Rev. JApril 2017 Rosemount 1066 smart - enabled , 2-Wire TransmitterEmerson designs, manufactures, and tests its Rosemount products to meet many national andinternational standards. Because these instruments are sophisticated technical products, you mustproperly install, use, and maintain them to ensure they continue to operate within their normalspecifications. The following instructions must be adhered to and integrated into your safetyprogram when installing, using, and maintaining Rosemount products. Failure to follow the properinstructions may cause any one of the following situations to occur: Loss of life; personal injury;property damage; damage to this instrument; and warranty invalidation.

Instruction Manual LIQ-MAN-1066 Rev. J April 2017 Rosemount™ 1066 Smart-Enabled, 2-Wire Transmitter

Tags:

  Smart, Wire, Transmitter, 0616, Enabled, Smart enabled, 2 wire transmitter, 1066 smart enabled

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Smart-Enabled, 2-Wire Transmitter - Emerson

1 Instruction ManualLIQ-MAN-1066 Rev. JApril 2017 Rosemount 1066 smart - enabled , 2-Wire TransmitterEmerson designs, manufactures, and tests its Rosemount products to meet many national andinternational standards. Because these instruments are sophisticated technical products, you mustproperly install, use, and maintain them to ensure they continue to operate within their normalspecifications. The following instructions must be adhered to and integrated into your safetyprogram when installing, using, and maintaining Rosemount products. Failure to follow the properinstructions may cause any one of the following situations to occur: Loss of life; personal injury;property damage; damage to this instrument; and warranty invalidation.

2 Read all instructions prior to installing, operating, and servicing the product. If this InstructionManual is not the correct manual, telephone 1-800-854-8257 and the requested manual willbe provided. Save this Instruction Manual for future reference. If you do not understand any of the instructions, contact your Emerson representative forclarification. Follow all warnings, cautions, and instructions marked on and supplied with the product. Inform and educate your personnel in the proper installation, operation, and maintenance ofthe product. Install your equipment as specified in the Installation Instructions of the appropriateInstruction Manual and per applicable local and national codes.

3 Connect all products to theproper electrical and pressure sources. To ensure proper performance, use qualified personnel to install, operate, update, program, andmaintain the product. When replacement parts are required, ensure that qualified people use replacement partsspecified by Rosemount. Unauthorized parts and procedures can affect the product sperformance and place the safe operation of your process at risk. Look alike substitutions mayresult in fire, electrical hazards, or improper operation. Ensure that all equipment doors are closed and protective covers are in place, except whenmaintenance is being performed by qualified persons, to prevent electrical shock and a 475 universal haRT Communicator is used with these transmitters, the software within the 475may require modification.

4 If a software modification is required, please contact your local EmersonService Group or National Response Center at : ExplOSION hazaRDDO NOT OpEN WhIlE CIRCuIT IS lIvE. ONly ClEaN WITh DaMp ignition hazard. Special condition for safe use (when installed in hazardous area) 1. The plastic enclosure, excepting the front panel, must only be cleaned with a damp cloth. Thesurface resistivity of the non-metallic enclosure materials is greater than one gigaohm. Caremust be taken to avoid electrostatic charge build-up. The 1066 Transmitter must not berubbed or cleaned with solvents or a dry The panel mount gasket has not been tested for type of protection IP66 or Class II and III.

5 Typeof protection IP66 and Class II, III refer the enclosure only. Essential InstructionsRead this page before proceedingEssential InstructionsINOTICEIIThis manual contains instructions for installation and operation of the 1066 smart following list provides notes concerning all revisions of this levelDateNotesA 1/2012 This is the initial release of the product manual. The manual has been reformatted to reflect the Emerson documentation style and updated to reflect any changes in the product 3/2012 This product manual version adds specifications and instrument instructions for Contacting Conductivity, Toroidal Conductivity, Chlorine, Oxygen, and Ozone 9/2012 This product manual version adds FM agency 3/2013 Updated CSA Intrinsically Safe Installation 7/2013 Updated CSA test Standards and Intrinsically Safe installation drawings and update CE certificates.

6 Added FM temperature specifications to Non-Incendive Hazardous Location 9/2013 Added Section 10: HART CommunicationsG 11/2014 Changed agency water exposure testing description to Type .H 05/2015 FM approvals 04/2017 Updated the Address and Emerson logo. Also, updated the FM, CSA installation drawings and CE this document3. The surface resistivity of the non-metallic enclosure materials is greater than one must be taken to avoid electrostatic charge build-up. The Model 1066 Transmitter mustnot be rubbed or cleaned with solvents or a dry Special Condition of Use of 1066 C FF/FII5 and 1066T FF/FII5. For use with simple apparatusmodel series 140, 141, 142, 150, 400, 401, 402, 402VP, 403, 403VP, 404, and 410VP contact-ing conductivity sensors and model series 222, 225, 226, 228 toroidal ManualTable of ContentsLIQ-MAN-1066 April 2017 ContentsSection 1: Quick Start Quick start 2: Description and and.

7 Specifications - Transmitter (pH input).. Specifications - Transmitter (ORP input).. Conductivity (Codes - C).. Sensors for Conductivity .. Conductivity (Codes - T).. Sensors for (Codes - L).. and Total Sensors .. Sensors .. Oxygen (Codes - DO).. Oxygen (Codes - DO).. 3: and General Conduit Section 4: .. Supply/Current Loop 1066 of ContentsIIIT able of ContentsInstruction ManualApril Supply and Load Supply-Current Loop Output Supply Wiring For 1066 Supply Wiring to Main 5: Intrinsically Safe Intrin sically Safe Installations ..27 Section 6: Display and 7: programming .. the Startup.

8 Temperature Units and Automatic/Manual Temperature .. and Ranging Current .. : Configure : Ranging the Current a Security .. the Security Code .. Hold .. the Hold Factory Default ..41 Section 8: programming ..44 IVTable of ContentsInstruction ManualTable of ContentsLIQ-MAN-1066 April Measurement .. Temperature Correction .. Measurement .. Offset .. Slope .. Factor .. Conductivity Measurement .. Measurement Chlorine Measurement ..54 Table of ContentsVTable of ContentsInstruction ManualApril .. Chlorine pH pH .. Chlorine Measurement .. Measurement : .. Measurement Measurement .. Press.

9 Measurement ..59 Section 9: .. Calibration a Known Slope Value sensor auto calibration upload and Redox Conductivity the Cell the the Sensor in a Conductivity Standard (in process cal).. the Sensor To A Laboratory Instrument (meter cal).. Factor ..73 VITable of ContentsInstruction ManualTable of ContentsLIQ-MAN-1066 April Conductivity the Cell the the Sensor in a Conductivity Standard (in process cal).. Free the Process Total the Process the Process the the Sensor in the Sensor Against A Standard Instrument (in process cal).. the Process ..85 Section 10: haRT Installation and Available via Available via Communication using the Device Specification (FDS).

10 100 APPENDIX Device Additional Transmitter Status Command 48 Status 1066 HART Configuration 475 Menu Tree for 1066 HART Section 11: Return of .. Declarations of of ContentsVIIVIIIT able of ContentsInstruction ManualApril 2017 LIQ-MAN-10661. For mechanical installation instructions, see page 14for panel mounting and page 15for pipeor wall mounting. 2. wire the sensor to the main circuit board. See pages 21-23for wiring instructions. Refer to thesensor instruction sheet for additional details. Make loop power Once connections are secured and verified, apply DC power to the Transmitter . 4. When the Transmitter is powered up for the first time, Quick Start screens appear.


Related search queries