Transcription of Smart-UPS Uninterruptible Power Supply
1 Operation Manual Smart-UPS . Uninterruptible Power Supply Tower 750/1000/1500/2200/3000 VA. 100/120/230 Vac 500 VA. 100 Vac Overview Product Description The APC by Schneider Electric Smart-UPS is a high performance Uninterruptible Power Supply (UPS). The UPS. provides protection for electronic equipment from utility Power blackouts, brownouts, sags, and surges, small utility Power fluctuations and large disturbances. The UPS also provides battery backup Power for connected equipment until utility Power returns to safe levels or the batteries are fully discharged.
2 This user manual is available on the enclosed CD and on the APC by Schneider Electric Web site, Important Safety Messages Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Caution product safety label indicates that a hazard exists that can result in injury and product damage if the instructions are not followed.
3 The following safety messages may appear throughout this manual to warn of potential hazards. CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or moderate injury. CAUTION. CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage. Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety Guide supplied with this unit before installing the UPS. Adhere to all national and local electrical codes.
4 This UPS is intended for indoor use only. Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation. The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient temperatures, poor quality utility Power , and frequent short duration discharges will shorten battery life. Connect the UPS Power cable directly to a wall outlet. Do not use surge protectors or extension cords.
5 The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment. The model and serial numbers are located on a small, rear panel label. For some models, an additional label is located on the chassis under the front bezel. Always recycle used batteries. Recycle the package materials or save them for reuse. Smart-UPS 750/1000/1500/2200/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower 1. Specifications For additional specifications, refer to the APC by Schneider Electric Web site at Environmental Operating 0 to 40 C (32 to 104 F).
6 Temperature -15 to 45 C (5 to 113 F). Storage charge UPS battery every six months Maximum Operating 3,000 m (10,000 ft). Elevation Storage 15,000 m (50,000 ft). Humidity 0% to 95% relative humidity, non-condensing 2 Smart-UPS 750/1000/1500/2200/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower Product Overview Front panel features 1 Display interface 500/750/1000/1500 VA 2200/3000 VA. 2 Bezel 3 Battery 4 Internal battery connector su0453a su0452a Rear panel features 500 VA to 1500 VA models 1 USB port 500/750 VA 100 Vac 750 VA 230 Vac 2 Serial port 750 VA 120 Vac 3 Chassis ground screw 4 SmartSlot 5 Circuit breaker 6 UPS input 7 Outlets su0326b 8 Internal or external battery connector su0327b 1000/1500 VA 100 Vac 1000/1500 VA 230 Vac 1000/1500 VA 120 Vac GROUP 1.
7 G RO U P 1. su0325c su0328c Smart-UPS 750/1000/1500/2200/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower 3. Rear panel features 2200 VA and 3000 VA models 2200 VA 120 Vac 1 USB Port 2 Serial port 3 Chassis ground screw 4 SmartSlot 5 Circuit breaker 6 UPS input 7 Outlets 8 EPO connector GROUP 1. su0351b 2200/3000 VA 100 Vac 2200/3000 VA 230 Vac 3000 VA 120 Vac GROU P 1. G R OU P 1. su0329b su0330a Installation For UPS installation information, refer to the Smart-UPS Installation Guide 750/1000/1500/2200/3000 VA 100/120/. 230 Vac, 500 VA 100 Vac Tower, that is included with the UPS.
8 The Installation guide is also available on the Documentation CD included with the UPS and on the APC by Schneider Electric Web site, 4 Smart-UPS 750/1000/1500/2200/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower Operation Connect Equipment CAUTION. RISK OF EQUIPMENT DAMAGE. Adhere to all local and national electrical codes. Wiring should be performed by qualified electrician. Always connect the UPS to a grounded outlet. Failure to follow these instructions can result in equipment damage Note: The 2200/3000 VA 100 Vac model UPS will charge to 90% capacity in the first four and a half hours of normal operation.
9 All other models will charge to 90% capacity in the first three hours of normal operation Do not expect full battery runtime capability during this initial charge period. 1. Connect equipment to the outlets on the rear panel of the UPS. 2. Connect the UPS to the building utility Power . Always connect the UPS to a two pole, three wire, grounded source. 3. To use the UPS as a master ON/O FF switch, turn on all the equipment that is connected to the UPS. 4. Press the ON/OFF button on the front panel of the UPS to turn on the UPS and all connected equipment.
10 See Main Outlet Group and Controlled Outlet Group on page 10 for information on how to configure the outlet groups. su0441a Rear Panel Features Serial port: Connect to a computer to use Power management software. USB port: Connect to a computer to use Power management software. Note: Serial and USB communication can not be used simultaneously. Ground Screw: The UPS features a ground screw for connecting the ground leads on transient voltage devices. Prior to connecting a ground lead, disconnect the UPS. from utility Power . Smart-UPS 750/1000/1500/2200/3000 VA 100/120/230 Vac / 500 VA 100 Vac Tower 5.