Example: stock market

SOLENOID PILOT VALVES - Pentair

RCA3 SOLENOIDPILOT VALVESGOYENCLEAN AIR SOLUTIONSPRODUCT LEAFLETGOYENPRODUCT LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES2 GOYEN - RCA3 SUITABLE FORAll Goyen dust collector diaphragm PILOT mounting hole in panel to ( ). Panel thickness must exceed mm ( ). Ensure o-ring is in place before tightening locknut. Preferably, install PILOT VALVES with SOLENOID on top. For reliable operation, ensure supply voltage is within 10% and +15% of rated SOLENOID voltage. Replace components within 1 million cycles (refer to Spare Parts).CONSTRUCTIONBody: Aluminium (diecast) Ferrule: 305 SS Armature: 430FR SS Seals: Nitrile or Viton Locknut: Mild steel zinc passivated Screws: 302 SS or 304 SS Clip: Mild steel (plated)OPERATIONR ecommended on time range: 50 500 ms Recommended time between pulses: 1 minute or greaterOPTIONSNoneAPPROVALS C-Tick CE EMC (2004/108/EC) and LV (2006/95/EC) CSARCA3D with flying lead connectionRCA3D with spade connectionRCA3D with DIN43650A connection* Please refer to Q Series SOLENOID product data sheet on page 3 for information on electrical characteristics and to complete the order code, 1 8 NPT PILOT valve with 240 VAC SOLENOID = RCA3D0-300 SERIESWEIGHTRCA3D0, RCA3D1 (no SOLENOID )

RCA – Pilot valve – Remote-controlled air Coil series 3 – Goyen ‘Q’ coil Valve type 3 – 1/8” Pipe thread Pilot size Body style ... SOLENOID PILOT VALVES 7 GOYEN - RCA3 SUITABLE FOR RCAC20T3, RCAC20ST3, RCAC20DD3, RCAC20FS3, RCAC25T3, RCAC25DD3, RCAC25FS3 dust collector valves only.

Tags:

  Solenoid, Pilots, Controlled, Pilot solenoid

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SOLENOID PILOT VALVES - Pentair

1 RCA3 SOLENOIDPILOT VALVESGOYENCLEAN AIR SOLUTIONSPRODUCT LEAFLETGOYENPRODUCT LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES2 GOYEN - RCA3 SUITABLE FORAll Goyen dust collector diaphragm PILOT mounting hole in panel to ( ). Panel thickness must exceed mm ( ). Ensure o-ring is in place before tightening locknut. Preferably, install PILOT VALVES with SOLENOID on top. For reliable operation, ensure supply voltage is within 10% and +15% of rated SOLENOID voltage. Replace components within 1 million cycles (refer to Spare Parts).CONSTRUCTIONBody: Aluminium (diecast) Ferrule: 305 SS Armature: 430FR SS Seals: Nitrile or Viton Locknut: Mild steel zinc passivated Screws: 302 SS or 304 SS Clip: Mild steel (plated)OPERATIONR ecommended on time range: 50 500 ms Recommended time between pulses: 1 minute or greaterOPTIONSNoneAPPROVALS C-Tick CE EMC (2004/108/EC) and LV (2006/95/EC) CSARCA3D with flying lead connectionRCA3D with spade connectionRCA3D with DIN43650A connection* Please refer to Q Series SOLENOID product data sheet on page 3 for information on electrical characteristics and to complete the order code, 1 8 NPT PILOT valve with 240 VAC SOLENOID = RCA3D0-300 SERIESWEIGHTRCA3D0, RCA3D1 (no SOLENOID ) lbFLOWMAXIMUM WORKING PRESSUREMINIMUM WORKING PRESSURETEMPERATURE MINTEMPERATURE MAXFLUID Cv/ Kv860 kPa/ 125 psi0 kPa/0 psi 40 C/ 40 F82 C/180 FAir or inert gasMODELTHREAD TYPEORIFICE mm ( ) mm ( )

2 DIMENSIONS AND WEIGHTS IN MM AND INCHESPRODUCT PERFORMANCEORDER CODE*RCA3D - REMOTE SOLENOID PILOT VALVE TO CONTROL THE ACTUATION OF DUST COLLECTOR DIAPHRAGM VALVESRCA3D with conduit entry connectionSPARE PARTSK0380 Nitrile replacement seal, armature, spring & ferrule As above in LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES3 GOYEN - RCA3 ORDER CODE AND ELECTRICAL CHARACTERISTICSRCA3D0 Series = 1/8 NPTMODELCONNECTION TYPEPROTECTION CLASSVOLTAGEPOWERRCA3D0 300 DIN 43650 AIP65200/240 V 50/60 V ARCA3D0 301 DIN 43650 AIP65100/120 V 50/60 V ARCA3D0 302 DIN 43650 AIP6524 V 50/60 V ARCA3D0 303 DIN 43650 AIP65110 V DC24 WRCA3D0 304 DIN 43650 AIP6548 V DC20 WRCA3D0 305 DIN 43650 AIP6524 V DC20 WRCA3D0 306 DIN 43650 AIP6512 V DC20 WRCA3D0 310 Conduit (M20 )IP31200/240 V 50/60 V ARCA3D0 311 Conduit (M20 )IP31100/120 V 50/60 V ARCA3D0 312 Conduit (M20 )IP3124 V 50/60 V ARCA3D0 313 Conduit (M20 )IP3124 V DC20 WRCA3D0 314 Conduit (M20 )IP3112 V DC20 WRCA3D0 320 Conduit ( NPSC)IP31200/240 V 50/60 V ARCA3D0 321 Conduit ( NPSC)IP31100/120 V 50/60 V ARCA3D0 322 Conduit ( NPSC)IP3124 V 50/60 V ARCA3D0 323 Conduit ( NPSC)IP3124 V DC20 WRCA3D0 324 Conduit ( NPSC)

3 IP3112 V DC20 WRCA3D0 330 Screw / spadeNA200/240 V 50/60 V ARCA3D0 331 Screw / spadeNA100/120 V 50/60 V ARCA3D0 332 Screw / spadeNA24 V 50/60 V ARCA3D0 333 Screw / spadeNA240 V DC24 WRCA3D0 334 Screw / spadeNA110 V DC24 WRCA3D0 335 Screw / spadeNA48 V DC20 WRCA3D0 336 Screw / spadeNA24 V DC20 WRCA3D0 337 Screw / spadeNA12 V DC20 WRCA3D0 340 Flying LeadIP64200/240 V 50/60 V ARCA3D0 341 Flying LeadIP64100/120 V 50/60 V ARCA3D0 342 Flying LeadIP6424 V 50/60 V ARCA3D0 343 Flying LeadIP6424 V DC20 WRCA3D0 344 Flying LeadIP6412 V DC20 WNotes: RCA3D0-305 is an RCA3D remote PILOT with 1/8 NPT threads and a 24 V DC DIN43650A LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES4 GOYEN - RCA3 ORDER CODE AND ELECTRICAL CHARACTERISTICSRCA3D1 Series = 1/8 BSPPMODELCONNECTION TYPEPROTECTION CLASSVOLTAGEPOWERRCA3D1 300 DIN 43650 AIP64200/240 V 50/60 V ARCA3D1 301 DIN 43650 AIP64100/120 V 50/60 V ARCA3D1 302 DIN 43650 AIP6424 V 50/60 V ARCA3D1 303 DIN 43650 AIP64110 V DC24 WRCA3D1 304 DIN 43650 AIP6448 V DC20 WRCA3D1 305 DIN 43650 AIP6424 V DC20 WRCA3D1 306 DIN 43650 AIP6412 V DC20 WRCA3D1 310 Conduit (M20 )IP31200/240 V 50/60 V ARCA3D1 311 Conduit (M20 )IP31100/120 V 50/60 V ARCA3D1 312 Conduit (M20 )IP3124 V 50/60 V ARCA3D1 313 Conduit (M20 )IP3124 V DC20 WRCA3D1 314 Conduit (M20 )IP3112 V DC20 WRCA3D1 320 Conduit ( NPSC)

4 IP31200/240 V 50/60 V ARCA3D1 321 Conduit ( NPSC)IP31100/120 V 50/60 V ARCA3D1 322 Conduit ( NPSC)IP3124 V 50/60 V ARCA3D1 323 Conduit ( NPSC)IP3124 V DC20 WRCA3D1 324 Conduit ( NPSC)IP3112 V DC20 WRCA3D1 330 Screw / spadeNA200/240 V 50/60 V ARCA3D1 331 Screw / spadeNA100/120 V 50/60 V ARCA3D1 332 Screw / spadeNA24 V 50/60 V ARCA3D1 333 Screw / spadeNA240 V DC24 WRCA3D1 334 Screw / spadeNA110 V DC24 WRCA3D1 335 Screw / spadeNA48 V DC20 WRCA3D1 336 Screw / spadeNA24 V DC20 WRCA3D1 337 Screw / spadeNA12 V DC20 WRCA3D1 340 Flying LeadIP64200/240 V 50/60 V ARCA3D1 341 Flying LeadIP64100/120 V 50/60 V ARCA3D1 342 Flying LeadIP6424 V 50/60 V ARCA3D1 343 Flying LeadIP6424 V DC20 WRCA3D1 344 Flying LeadIP6412 V DC20 WNote: RCA3D1-331 is an RCA3D remote PILOT with 1 8 BSPP threads and 110/240 V AC spade screw LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES5 GOYEN - RCA3 DIMENSIONS IN MM (AND INCHES)FOR INTEGRAL PILOT (CA) APPLICATIONSThe RCA3DM is a PILOT valve with an integral silencer and dust shroud which mounts directly (screw-in) to the 4 series valve and RCA3PV are suitable piloting options for all 4 Series VALVES and the RCA35T diaphragm CONSTRUCTIONBody: Aluminium (diecast) Encapsulation: PA-66 C-Frame: Mild steel, zinc passivated Bobbin: PA-66 Insulation class: B/130 C IP Rating: IP65 Rating: Non-continuous use only Clip: Mild steel (mechanically plated)OPERATIONR ecommended on time range: 50 500 ms Recommended time between pulses.

5 1 minute or greaterAPPROVALS C-Tick EMC (89/336/CE) CE EMC (2004/108/EC) and LV (2006/95/EC) CSASPARE PARTSK0380 Nitrile replacement seal, armature, spring & ferrule As above in refer to next page for replacement coil - PILOT VALVEGOYENPRODUCT LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES6 GOYEN - RCA3 RCA3DM - HOW TO ORDER RCA PILOT valve Remote- controlled airCoil series3 Goyen Q coilValve type3 1/8 Pipe threadPilot sizeBody styleDM Male inlet, R 1/8 thread, suits all Series 4 RCAC VALVES -103MD3 ACRFLOWMAXIMUM WORKING PRESSUREMINIMUM WORKING PRESSURETEMPERATURE MINTEMPERATURE MAXFLUID Kv860 kPa/125 psi0 kPa/0 psi 40 C/ 40 F 29 C/ 20 F82 C/180 F232 C/450 FAir or inert gasPRODUCT PERFORMANCEDIN SOCKET CONNECTORPg9 connection (cable entry)DIN SOCKET SPECIFICATIONEN175301 - 803 (previously DIN 43650A) / A/ISO 4400 DIN SOCKET OPTIONAL94/9/CE ATEX II 3GD T6 ISOLATION CLASS DIN SOCKETVDE 0110 - 1/89 DIN SOCKET PROTECTIONIP65 EN60529 ELECTRICAL CHARACTERISTICSMODELTYPECONNECTION TYPEPROTECTION CLASSVOLTAGEPOWERCOLOUR300 QRDIN 43650 AIP64200/240 V 50/60 V AGrey301 QRDIN 43650 AIP64100/120 V 50/60 V AGrey302 QRDIN 43650 AIP6424 V 50/60 V AGrey303 QRDIN 43650 AIP64110 V DC24 WGrey304 QRDIN 43650 AIP6448 V DC20 WGrey305 QRDIN 43650 AIP6424 V DC20 WGrey306 QRDIN 43650 AIP6412 V DC20 WGrey310 QDConduit (M20 )IP31200/240 V 50/60 V AGreen311 QDConduit (M20 )IP31100/120 V 50/60 V AGreen312 QDConduit (M20 )IP3124 V 50/60 V AGreen313 QDConduit (M20 )IP3124 V DC20 WGreen314 QDConduit (M20 )IP3112 V DC20 WGreen320 QDConduit ( NPSC)

6 IP31200/240 V 50/60 V AGreen321 QDConduit ( NPSC)IP31100/120 V 50/60 V AGreen322 QDConduit ( NPSC)IP3124 V 50/60 V AGreen323 QDConduit ( NPSC)IP3124 V DC20 WGreen324 QDConduit ( NPSC)IP3112 V DC20 WGreenGOYENPRODUCT LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES7 GOYEN - RCA3 SUITABLE FORRCAC20T3, RCAC20ST3, RCAC20DD3, RCAC20FS3, RCAC25T3, RCAC25DD3, RCAC25FS3 dust collector VALVES only. INSTALLATIONE nsure o-ring is in place on diaphragm valve cover. Gripping the shroud, hand tighten 3DS PILOT valve onto cover of diaphragm valve. For reliable operation, ensure supply voltage is within 10% and +15% of rated SOLENOID voltage. SOLENOID is free to rotate on PILOT valve. 3DS thread will suit 1/8 BSP T, 1/8 BSP P and 1 8 NPT ports. Replace PILOT components within 1 million cycles (refer to Spare Parts). CONSTRUCTIONBody: AI 2011-T3 Ferrule: 302 SS Armature: 430FR SS Encapsulation: PA-6 Insulation: Class B/130 C Seals: Nitrile Shroud: PA-6 OPERATIONR ecommended on time range: 50 500 ms Recommended time between pulses.

7 1 minute or greaterOPTIONSNoneAPPROVALS C-Tick EMC (89/336/CE)DIMENSIONS AND WEIGHTS IN MM3DS 03DS 310 to lb3DS-300 to 3DS lb3DS-310 to 3DS lbFLOWMAXIMUM WORKING PRESSUREMINIMUM WORKING PRESSURETEMPERATURE MINTEMPERATURE MAXFLUID Cv/ Kv860 kPa/ 125 psi0 kPa/0 psi 40 C/ 40 F82 C/180 FAir or inert gasPRODUCT PERFORMANCE3DS - PILOT VALVE WITH INTEGRAL SILENCER AND DUST SHROUD TO MOUNT DIRECTLY TO DUST COLLECTOR DIAPHRAGM VALVE3DS 300 to 3DS-306 SPARE PARTSK0380 Nitrile replacement seal, armature, spring & ferrule As above in LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES8 GOYEN - RCA3 ORDER CODE AND ELECTRICAL CHARACTERISTICS3 DSMODELCONNECTION TYPEPROTECTION CLASSVOLTAGEPOWER3DS 300 DIN 43650 AIP64200/240 V 50/60 V A3DS 301 DIN 43650 AIP64100/120 V 50/60 V A3DS 302 DIN 43650 AIP6424 V 50/60 V A3DS 303 DIN 43650 AIP64110 V DC24 W3DS 304 DIN 43650 AIP6448 V DC20 W3DS 305 DIN 43650 AIP6424 V DC20 W3DS 306 DIN 43650 AIP6412 V DC20 W3DS 310 Conduit (M20 )IP31200/240 V 50/60 V A3DS 311 Conduit (M20 )IP31100/120 V 50/60 V A3DS 312 Conduit (M20 )IP3124 V 50/60 V A3DS 313 Conduit (M20 )IP3124 V DC20 W3DS 314 Conduit (M20 )IP3112 V DC20 W3DS 320 Conduit ( NPSC)IP31200/240 V 50/60 V A3DS 321 Conduit ( NPSC)IP31100/120 V 50/60 V A3DS 322 Conduit ( NPSC)

8 IP3124 V 50/60 V A3DS 323 Conduit ( NPSC)IP3124 V DC20 W3DS 324 Conduit ( NPSC)IP3112 V DC20 WGOYENPRODUCT LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES9 GOYEN - RCA3 DIMENSIONS IN MM (AND INCHES)FOR INTEGRAL PILOT (CA) APPLICATIONSThe RCA3PV PILOT is another option for integral PILOT (CA) applications. The RCA3PV PILOT is a screw-in PILOT available in 1/8 and port and RCA3PV are suitable piloting options for all 4 Series VALVES and the RCA35T diaphragm CONSTRUCTIONE ncapsulation: Nylon Insulation class: H /180 C IP Rating: IP65 Rating: Non-continuous use only Clip: Mild steel (mechanically plated))OPERATIONR ecommended on time range: 50 500 ms Recommended time between pulses: 1 minute or greaterAPPROVALS CE LV (2006/95/EC) ROHS (2002/95/CE)SPARE PARTSNo PILOT valve overhaul kits are available for the RCA3PV PILOT ; however, coil kits are available as listed below:K0203 Dual rating: 110 V DC 18 W or 220/240 V 50/60 Hz kit includes coil, stabilus clip and Dual rating: 48 V DC 18 W or 115 V 50/60 Hz kit includes coil, stabilus clip and washer.

9 K0205 Dual rating: 24 V DC 18 W or 48 V 50/60 Hz kit includes coil, stabilus clip and Dual rating: 12 V DC 18 W or 24 V 50/60 Hz kit includes coil, stabilus clip and - PILOT VALVEGOYENPRODUCT LEAFLETSOLENOID PILOT VALVESSOLENOID PILOT VALVES10 GOYEN - RCA3 RCA3PV/3PV2 - HOW TO ORDERFLOWMAXIMUM WORKING PRESSUREMINIMUM WORKING PRESSURETEMPERATURE Kv860 kPa/125 psi0 kPa/0 psi 40 C/ 40 F82 C/180 FAir or inert gasPRODUCT PERFORMANCEDIN SOCKET CONNECTORPg9 connection (cable entry)DIN SOCKET SPECIFICATIONEN175301 - 803 (previously DIN 43650A) / A/ISO 4400 DIN SOCKET OPTIONAL94/9/CE ATEX II 3GD T6 ISOLATION CLASS DIN SOCKETVDE 0110 - 1/89 DIN SOCKET PROTECTIONIP65 EN60529 ELECTRICAL CHARACTERISTICSMODELTYPECONNECTION TYPEPROTECTION CLASSVOLTAGEPOWERCOLOUR206SB4 DIN 43650 AIP6512 V DC (max. +10% supply)18 WBlack205SB4 DIN 43650 AIP6524 V DC (max.)

10 +10% supply)18 WBlack204SB4 DIN 43650 AIP6548 V DC (max. +10% supply)18 WBlack203SB4 DIN 43650 AIP65110 V DC (max. +10% supply)18 WBlack206SB4 DIN 43650 AIP6524 V 50/60 Hz (max. +10% supply)38/31 VABlack205SB4 DIN 43650 AIP6548 V 50/60 Hz (max. +10% supply)41/32 VABlack204SB4 DIN 43650 AIP65110/127 V 50/60 Hz (max. +10% supply)63/53 VABlack203SB4 DIN 43650 AIP65220/240 V 50/60 Hz (max. +10% supply)46/37 VABlack RCA PILOT valve Remote- controlled air RCA 3 PV 2-2 0 5 Valve type3 1/8 Pipe thread PILOT sizePV Male inlet, suits all RCA and RCAC main VALVES Body styleBlank R1/8 thread2 G1/4 thread Thread type2 DIN 43650 Form B connectionCoil series0 Square DIN connectorCoil connection3 Dual rating: 110V DC 18W or 220/240V 50/60Hz 46/37VA4 Dual rating: 48V DC 18W or 115V 50/60Hz 63/53VA5 Dual rating: 24V DC 18W or 48V 50/60Hz 41/32VA6 Dual rating: 12V DC 18W or 24V 50/60Hz 38/31 VAVoltage options Remote PILOT valve RCA3PV