Spiracoustic Plus - Johns Manville
Round Duct Liner System DESCRIPTION Spiracoustic Plus® duct liner, bonded with a thermosetting resin, is specifically engineered to provide very high acoustical and thermal performance in round air ducts of virtually any size. Based on high-density fiber glass board technology, Spiracoustic Plus duct liner has factory-made, evenly spaced kerfs
Tags:
Board, Liner, Duct, Duct liner
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Advertisement
Documents from same domain
SBS Modified Bitumen Specifications - Johns Manville
www.jm.com3-79 SBS Modified Bitumen Specifications 7.0 Roofing Bitumens 7.1 JM modified bitumen products are designed to be installed with hot asphalt or special cold …
Specification, Modified, Cold, Bitumen, Sbs modified bitumen specifications
IIG Product Selector Guide - jm.com
www.jm.comMinWool-1200® Field-Formed Pipe Mineral Wool Insulation AVAILABLE SHAPES AND SIZES Standard Thickness Single Layer: 1½-4” thick Double Layer: Over 4” …
Formaldehyde-free™ Fiberglass Insulation
www.jm.comSAFETY DATA SHEET 200000002059 Formaldehyde-free™ Fiberglass Insulation Version 1.6 Revision Date 09/25/2018 Print Date 10/03/2018 1 / 6 US/EN SECTION 1. PRODUCT AND COMPANY IDENTIFICATION Trade name : Basement Wall Insulation® - Unfaced, Steel Frame Thermal and Acoustical Fiberglass Insulation, Spin-Glas® TC EQ, ...
AP Foil-Faced - jm.com
www.jm.comDESCRIPTION Johns Manville AP™ Foil-Faced Polyiso Continuous Insulation board consists of a uniform closed-cell polyisocyanurate foam core bonded on each side to a foil facer. One side has a reflective foil facer and the other side has a white non-reflective foil facer to suit your building needs.
FESCANT PLUS CANT STRIP TAPERED FESCOEDGE STRIP
www.jm.comFESCANT PLUS CANT STRIP TAPERED FESCO ® EDGE STRIP Perlite-Based Specialty Accessory Product Typical Physical Properties* Test ASTM FesCant Plus Cant Strip* Tapered FESCO Edge Strip*
Plus, Strips, Tapered, Reptiles, Ncat, Fescant plus cant strip tapered, Fescant
Mineral Wool Insulation - Johns Manville
www.jm.comSAFETY DATA SHEET 200000002057 Mineral Wool Insulation Version 2.1 Revision Date 02/26/2018 Print Date 02/26/2018 3 / 6 US/EN Materials to avoid
EXPAND-O-FLASHEXPANSION JOINT COVER
www.jm.comEXPAND-O-FLASH ® EXPANSION JOINT COVER Flexible, Weatherproof Joint Opening Covers. RS-6016 2-17 (Replaces 10-14) Features and Components Expand-O-Flash expansion joint covers are flexible, weather-proof
Cover, Joint, Expansion, Expand, Expand o flashexpansion joint cover, Flashexpansion
Asphalt-Applied and Cold Application Built-Up Roofing ...
www.jm.comAsphalt-Applied and Cold Application Built-Up Roofing Application Guide. Built-Up Roofing Application Guide TWO SECTION 2-2 RS-4927 2-14 (Replaces 11-13) Asphalt-Applied and Cold Application Built-Up Roofing Application Guide 3.2 These specifications are also for use over JM roof ... Do not mix different grades of asphalt or dilute asphalt with ...
Guide, Applications, Applied, Cold, Asphalt, Built, Asphalt applied and cold application built
SBS Modified Bitumen Specifications
www.jm.com3-77 SBS Modified Bitumen Specifications 1.0 General Information 1.1 This section provides application information, and outlines specifications currently available from JM Roofing Systems for SBS (Styrene-Butadiene-Styrene) Modified Bitumen Roofing Membranes.
Specification, Modified, Bitumen, Sbs modified bitumen specifications
EXPAND-O-FLASHEXPANSION JOINT COVER
www.jm.comEXPAND-O-FLASH ® EXPANSION JOINT COVER Flexible, Weatherproof Joint Opening Covers. RS-6016 8-18 (Replaces 2-17) Features and Components Expand-O-Flash expansion joint covers are flexible, weather-proof
Related documents
GYPSUM PANEL PRODUCTS TYPES, USES, SIZES, AND …
www.gypsum.orgGypsum Shaft Liner Board Shaft, Stairway, Duct Enclosures, Area Separation Walls, Base for Solid or Semi-Solid Partitions C 1396, C 442 GA-216, † 1, 2 13. Predecorated Gypsum Board Accent Walls, Office & Movable Partitions C 1396, C 960 GA-224 1, 2, 3 14. Gypsum Board for Manufactured Housing Manufactured Housing Walls & Ceilings
Product, Types, Board, Size, Uses, Panels, Liner, Duct, Gypsum, Gypsum panel products types, Liner board
A GUIDE TO INSULATED HVAC DUCT SYSTEMS
insulationinstitute.orgDuct systems fabricated from fibrous glass duct board products qualify under UL 181 as Class 1 Air Ducts, meeting the fire safety requirements of NFPA 90A and 90B including limited combustibility. They also comply with all widely used model codes. Duct board joint closures are sealed using one of three UL 181A listed systems.
Trane Product Data Variable Speed Modular Multi-position ...
www.trane.comBAYINSKT175A Solcoustic® Liner Kit for 17.5” cabinet A BAYINSKT215A Solcoustic® Liner Kit for 21.5” cabinet B BAYINSKT235A Solcoustic® Liner Kit for 23.5” cabinet C BAYCNDPIP01A 3/4” PVC Threaded Pipe Kit foam Seal (10 per box) A to C BAYAHEMIKIT001A EMI/EFI Air Handler Electronic noise kit for variable speed blower motor A to C
Sheetrock Wall Liner Gypsum Panels - USG
www.usg.commechanical or duct enclosures, or in areas where a small section of shaft wall is needed for a single vertical pipe penetration. See page 21 for more information. For certain applications, equipment limitations sometimes make it difficult to install shaft liner panels and studs vertically. This is true for walls
SHAFTLINER FOR SHAFTWALL/STAIRWELL SYSTEMS
www.buildgp.comboard or 1/2” (12.7 mm) DensArmor Plus® Interior Panel horizontally with 1” (25.4 mm) Type S or S-12 screws spaced 24” (610 mm) o.c. starting 3” (76 mm) from top and bottom. (5/8” (15.9 mm) DensArmor Plus ® Fireguard ® gypsum panels may be
USG SHAFT WALL SYSTEMS - BuildSite
www.buildsite.comSolid shafts are normally used to construct mechanical or duct enclosures, or in areas where a small section of shaft wall is needed for a single vertical pipe penetration. See page 21 for more information. For certain applications, equipment limitations sometimes make it diicult to install shaft liner panels and studs vertically. This is true fo r
Submittal Sheet - Price Industries
www.priceindustries.comsingle duct terminal variable volume h 4 3/4" (121) w 9 1/2" (241) 2" (51) 18 1/2" (470) b a l d optional nema1 controls enclosure 6 3/8" (162) size 4 & 5 only multi-point sensor optional access door standard construction: • 1/2" (13mm) thick internal fiberglass insulation which meets requirements of nfpa 90a and ul181.