Additional Charge of Refrigerant (oz/ft) .21 Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 8.60 Refrigerant Oil PVE (FVC50K) Airflow Rate (cfm) Cooling Heating H 3,684 H 3,356 M 3,029 M 3,138 L 2,756 L 1,500 Sound Power Level (dBA) 52 / 55
Tags:
Refrigerant, 410a, R refrigerants
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
DCC Commercial - daikinac.com
www.daikinac.comJob Name Location Job Name Location 2 www.daikinac.com SS-DCC7 SS-DCC7 www.daikinac.com 3 Performance Data Cooling Performance Tota Capacity MBH Sensible Capacity MBH
00 CV 3P243521-7L - daikinac.com
www.daikinac.comEnglish Français Español Be sure to read this installation manual before installing this product. Mode On/Off Fan Speed Cancel Menu OK MODEL BRC1E73 WIRED REMOTE
THE - Daikin AC
www.daikinac.comTHE DAIKIN EDGE Daikin is the only company in the world dedicated to manufacturing both air‐conditioning systems and refrigerants.
Daikin MXS SERIES MULTI-ZONE HEATING SYSTEMS
www.daikinac.comAir Intelligence built-inside A better understanding of how people inhabit their living spaces has led to products designed to create indoor environments that help use
OPERATION MANUAL - daikinac.com
www.daikinac.comMODEL BRC7E83 OPERATION MANUAL Read these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with the equipment owner.
00 CV 3P329626-1 - daikinac.com
www.daikinac.comEnglish 3 System Layout For installation of the indoor and outdoor units, follow the instructions in the Installation manual for each unit. B A Power
COMMERCIAL WARRANTY - Daikin AC
www.daikinac.comFor more information about the warranty, contact Daikin
00 CV 3P177429-11X - daikinac.com
www.daikinac.comOPERATION MANUAL English Français Español SPLIT SYSTEM Air Conditioners MODELS Ceiling mounted cassette type (Round …
Installation Manual - daikinac.com
www.daikinac.comInstallation Manual Rev1. 00 Date 11-2013 1. WARNINGS, ENVIRONMENTAL POLICY, AND CERTIFICATIONS 1.1. Warnings For personal safety and equipment protection, follow these instructions:
DCG Commercial - daikinac.com
www.daikinac.comSS-DCG7 wwwdaiinao 2/18 Supersed Å Ì DCG Commercial 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% T.E. Cooling Capacity: 88,000 — 146,000 BTU/h
Commercial, Daikinac, Dcg commercial daikinac, Dcg commercial
Related documents
SERVICE MANUAL R 410A Ductless Split System Air ...
icpindexing.toddsit.comRefrigerant Name of Refrigerant R410A R410A Weight Oz. 42 42 Connection Pipe Length (m) Ft. 16 16 Gas Additional Charge Oz/ft 1.1613 1.1613 Liquid Pipe Diameter inch Gas Pipe Diameter inch 3/8 3/8 Max. Interunit height Difference Ft. 33 33 Max. Interunit Piping Length Ft. 66 66 * The above data is subject to change without notice.
Submittal Data Sheet FTXB24AXVJU / RXB24AXVJU
backend.daikincomfort.comRefrigerant R-410A Factory Charge (Lbs) 3.20 Refrigerant Oil PVE (FVC50K) Airflow Rate (cfm) Cooling Heating H 1796 H 1796 Sound Pressure Level (dBA) 52 Dimensions (H × W × D) (in) 29-11/16 × 33-11/16 × 12-15/16 Weight (Lbs) 97 Job Name: Tag# Complete warranty details available from your local dealer or at www.daikincomfort.com.
Submittal Data Sheet FTX36NVJU / RX36NMVJU
www.daikinac.comRefrigerant R-410A PVE (FVC50K) Airflow Rate (cfm) Cooling Heating H 2,811 H 2,352 Sound Power Level (dBA) 59 Dimensions (H × W × D) (in) 28-15/16 × 34-1/4 × 12-5/8 Weight (Lbs) 133 Job Name: Tag# Complete warranty details available from your local dealer or at www.daikincomfort.com. Warranty registration not required to
PRODUCT CATALOG
aspenmfg.comF= R-22 Flo-rater G = R-410A Flo-rater X = non-bleed A/C or H/P R22 TXV 6 CA, DA Series: Drain pan width code CB, CC, CE, CR, CS, DC, DE, DR, DS Series: Furnace width code CH Series: cabinet width code 7 Refrigerant and plumbing connections L = left-hand plumbing and refrigerant connections R = right-hand plumbing and refrigerant connections
The Future of Air Conditioning for Buildings
www.energy.govdepleting HFCs and HFC blends (e.g., R-410A and R-134a) have replaced HCFC and CFC refrigerants and now dominate the industry in developed countries. However, the GWPs of today’s most common refrigerants are over a thousand times more powerful than the most prevalent GHG, carbon dioxide.
Product Data - Carrier
www.shareddocs.comProduct Data 25HHA4 Performance Series Heat Pump with Puron Refrigerant 1-1/2 to 5 Nominal Tons Carrier Heat Pumps with Puron refrigerant provide a collection of features unmatched by any other family of equipment. The 25HHA4 has been designed utilizing Carrier’s Puron refrigerant. This environmentally sound refrigerant allows you to make a
Product Data - Carrier
www.shareddocs.comProduct Data 25HCB6 Performancet 16 2---Stage Heat Pump with Puronr Refrigerant 2to5Tons Carrier Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCB6 has been designed utilizing Carrier’s Puron refrigerant. The environmentally sound refrigerant allows you to
PRESSURE TEMPERATURE CHART - URI.com
www.uri.comR-1234yf belongs to a new family of HFOs (hydro-fluoro-olefins) that have a low GWP. R-1234yf is intended for automotive air conditioning systems, some other R-134a applications, and it is a component in some HFC blends to help lower the overall GWP. This product is mildly flammable, but has been deemed safe by itself in new automotive systems.
Chart, Product, Pressure, Temperatures, Pressure temperature chart