Example: dental hygienist

SUBMITTAL DATA SHEET - Master Group

SUBMITTAL data SHEETCONDENSING HIGH EFFICIENCY DOWNFLOW/HORIZONTAL MODULATING GAS FURNACES WITH ECM MOTORMODELS: PC9*DHHeatingAir ConditioningR Unitary Products Group7260132-YSD-D-0108 JOB NAME: LOCATION:PURCHASER:ORDER NO:ENGINEER: SUBMITTED TO:FOR: REF:APPROVAL:CONSTRUCTION:SUBMITTED BY:DATE:UNIT DESIGNATION:SCHEDULE DATAH eating PerformanceInput Capacity _____ MBHO utput Capacity _____ MBHAir Temp.

submittal data sheet ... vent pipe 0 rear 0 l & r sides 0 ... concentric vent termination - 1ct0302 (2") 1ct0303 (3") condensate neutralizer kit - 1ht0901

Tags:

  Sheet, Data, Vents, Submittal, Submittal data sheet, Concentric, 1ct0302, 1ct0303, Concentric vent

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SUBMITTAL DATA SHEET - Master Group

1 SUBMITTAL data SHEETCONDENSING HIGH EFFICIENCY DOWNFLOW/HORIZONTAL MODULATING GAS FURNACES WITH ECM MOTORMODELS: PC9*DHHeatingAir ConditioningR Unitary Products Group7260132-YSD-D-0108 JOB NAME: LOCATION:PURCHASER:ORDER NO:ENGINEER: SUBMITTED TO:FOR: REF:APPROVAL:CONSTRUCTION:SUBMITTED BY:DATE:UNIT DESIGNATION:SCHEDULE DATAH eating PerformanceInput Capacity _____ MBHO utput Capacity _____ MBHAir Temp.

2 Rise_____ F Supply Air Blower PerformanceTotal Supply Air_____CFMT otal External Static Pressure _____ IWGB lower Speed (circle) _____HI MH ML LMotor Rating _____HPElectrical DataPower Supply 115 / 1 / 60 Total Unit Ampacity _____AMPSM inimum Wire Size _____AWGM aximum Overcurrent Device Fuses Circuit Breaker____AMPSUnit WeightTotal Unit Weight _____LBSCLEARANCESDOWNFLOWTo p1 Front3 Vent Pipe0 Rear0L & R Sides0 Bottom1 *HORIZONTALTo p0 Front3 Vent Pipe0 Rear0L & R Sides1 BottomMay be applied directly on a combustible floor* Combustible floor base or A/C coil requiredfor use on combustible floorDIMENSIONS - INCHESM

3 OdelsCFMCABINETSIZECABINET DIMENSIONA (in.)B (in.)C (in.)D (in.)E (in.)PC9B12N060DH111200B17-1/216-1/4151- 3/42-3/8PC9B12N080DH111200B17-1/216-1/41 51-3/42-3/8PC9C16N080DH111600C2119-3/418 -1/22-1/82-3/4PC9C16N100DH111600C2119-3/ 418-1/22-1/82-3/4PC9C20N100DH112000C2119 -3/418-1/22-1/82-3/4PC9D20N120DH112000D2 4-1/223-1/4222-1/23C19-1/41-1/41-1/45/85 /823-5/8D2-1/423-1/420 BBOTTOM IMAGESUPPLY ENDTOP IMAGERETURN ENDFRONTLEFT SIDERIGHT SIDE22-3/47/87/813-7/8 HORIZONTAL CONDENSATEDRAIN OPENING 2 JUNCTION BOXHOLE 7/8 GAS PIPE ENTRY 1-1/2 CONDENSATE DRAINHOLE 7/8 SIDE PIPING HOLE 3-3/8 T-STAT

4 WIRING 7/8 CONDENSATEDRAIN OPENING 1-3/4 22-1/425-3/826-1/227-1/82922-3/421-5/818 -1/211-3/47-1/22-1/4T-STAT WIRING 7/8 CONDENSATEDRAIN OPENING 1-3/4 HORIZONTALCONDENSATEDRAIN OPENING 1-3/4 JUNCTION BOXHOLE 7/8 GAS PIPEENTRY 1-1/2 CONDENSATE DRAINHOLE 7/8 2922-3/421-1/418-1/29-1/88-1/230-1/8A40 EFFICIENCYRATINGCERTIFIEDISO 9001 Certified QualityManagement SystemSubject to change without notice. Printed in by Unitary Products Group . 2008. All rights reserved. Supersedes: 260132-YSD-C-0606 Unitary5005 NormanProductsYorkOKGroupDrive73069 FEATURES Compact, easy to install, ideal height 40" cabinet.

5 May be installed as either two-pipe (direct vent) or single-pipe vent (using indoor combustion air) Blower-off delay for cooling SEER improvement. Easy to connect power/control wiring. Built-in, high level self diagnostics with fault code display. Low unit amp requirement for easy replacement application. Integrated control module for reliable, economical operation. Insulated blower compartment for quiet operation. Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability. Induced combustion system with inshot main burners for quiet, efficient operation.

6 No special vent termination kit required. 100% shut off main gas valve for extra safety. ECM High-efficiency, direct drive motor with large, quiet blower. 24V, 40 VA control transformer and blower relay supplied for add-on cooling. Hi-tech tubular aluminized steel primary heat exchanger. Secondary (condensing) heat exchanger of 29-4C high-grade stainless steel. Timed on, adjustable off blower capability for maximum comfort. Internal vent coupling for maximum serviceability. Independent door removal for greater durability and ease of access.

7 3-way transition facilitates fresh air piping. Modulating heating operation includes:- Modulating gas valve- Modulating inducer operationFIELD INSTALLED ACCESSORIESPROPANE (LP) CONVERSION KIT - 1NP0680 - All unitsThis accessory conversion kit may be used to convert naturalgas (N) units for propane (LP) operation. Conversions mustbe made by qualified distributor or dealer VENT TERMINATION - 1ct0302 (2") 1ct0303 (3")CONDENSATE NEUTRALIZER KIT - 1HT0901 Neutralizer cartidge has a 1/2" plastic tube fittings for installa-tion in the drain line.

8 Calcium carbonate refill media is alsoavaiable from the Source 1 Parts (p/n 026-30228-000).SIDEWALL VENT TERMINATION - 1HT0901 (3")1HT0902 (2")For use on sidewall, two-pipe installations only. Provide amore attractive termination for locations where the terminal isvisable on the side of the FLOOR BASE - 1CB0317 - 17 1/2 Cabinet1CB0321 - 21 Cabinet1CB0324 - 24-1/2 CabinetCOIL TRANSITION - 1TK0917 - 17 1/2 Cabinet1TK0921 - 21 Cabinet1TK0924 - 24-1/2 CabinetRequired in downflow applications when using G*FD series : _____ _____