Example: quiz answers

SUPER-TITAN - tkl.com.au

SUPER-TITAN Split-casepumps with power, performance and reliability for a world of applicationsThe PUMPSThe Best JustGot Thompsons Kelly & LewisSuper- titan split-case pumphas long been used for thehandling of liquids where theutmost in reliability and maintainability are first glance, the TKL SUPER-TITAN pump may look like any other split-case , a close look inside will show how special attentiondevoted to design of the component parts makes the TKL SUPER-TITAN pump different, a leader among split-case TKL SUPER-TITAN pump makes a significant contribution to the operator s numerous design features offer longer life of all parts.

The Prestige. The Performance. SUPER-TITAN PUMPS ™ The Best Just Got Better. The Thompsons Kelly & Lewis Super-Titan split-case pump has long been used for the

Tags:

  Super, Titan, Super titan

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SUPER-TITAN - tkl.com.au

1 SUPER-TITAN Split-casepumps with power, performance and reliability for a world of applicationsThe PUMPSThe Best JustGot Thompsons Kelly & LewisSuper- titan split-case pumphas long been used for thehandling of liquids where theutmost in reliability and maintainability are first glance, the TKL SUPER-TITAN pump may look like any other split-case , a close look inside will show how special attentiondevoted to design of the component parts makes the TKL SUPER-TITAN pump different, a leader among split-case TKL SUPER-TITAN pump makes a significant contribution to the operator s numerous design features offer longer life of all parts.

2 Our engineers considered the many service needs of modern general purpose pumps: higher operating pressures,dependability for continuous operation in process applications, high efficiency for economical operation, low monitoring and maintenance on any TKL SUPER-TITAN , a rugged, dependable and efficient pump meets all these 001 Single or double volute foroptimum hydraulic performance. Split onhorizontal centreline - no need to disturb pipingor motor for WEAR RINGS 007 Renewable case ringseliminate casing wear. Low cost replace-ment torefurbish to design 002 Double suction arrangementrequires minimum NPSH.

3 Balanced constructionreduces thrust loads and prolongs bearing HOUSING 099 Designed for shortbearing span, flanged and doweled for easyrotating element removal and accuratealignment on reassembly. Five standard greaselubricated bearing elements cover completepump range, reducing operators spare high intensity operation, the bearing housing099 on larger models can be furnished withintegrally cast cooling jackets and 560/561 Pre-lubricated single anddouble row angular contact anti-friction bearingssized to give long life under the toughestconditions of radial and axial load.

4 Waterthrowers and grease seals protect bearings frommoisture and 006 Large diameter and short spanminimises shaft deflection and prolongs sealand bearing SLEEVES 014 Renewable to protect theshaft. Threaded to axially locate and lock theimpeller inboard of the shaft seals. Thread isopposed to direction of shaft BOXES Fitted with renewable neckbushes 063, lantern rings 029, high qualitypacking 581 and split glands 017 as seals are CONFIGURATION Space savingdesign with most of the features of thehorizontal version and in addition the pump issupplied with a pump support stool 023 andmotor mounting flange 081.

5 The external upperbearing 560/561 carries all thrust and radialloads, the internal lower sleeve bearing 039 isliquid The standard TKL SUPER-TITAN pump isdesigned to meet most requirements. However,to satisfy special conditions, a number ofoptional configurations are available: Seal flush through cyclone separator to filterliquid supply to the stuffing boxes, and to thebottom bearing of vertical pumps. Quench glands for temperatures above 105 C. High-speed kit with extended neck bushes innon-metallic material forpump operation above 1500 r/min.

6 Splash guards to contain excessive spray fromgland leakage. Pressure gauge tappings on pump branches. Grease nipples fitted to bearing covers. Air and drain piping to a common dischargepoint. Increased sealing ring clearances for dirty water operation. Opposite-hand shaft rotation; standardrotation is clockwise viewed from drive end. Alternative flange ShaftSingle VoluteHorizontal Shaft DoubleVoluteVertical ShaftPUMP DESIGNATIONPUMP & PUMP SUPPORTDIADIANOMD ischarge Suction IMP DIA Frameabc de+fgh1h2h3 460 28055372519413 425292 318 965 580370 625200250400A12410 410 28055402549443 425254 279 965 600470 625200250400B12410 410 28055402549443 425254 279 965 600470 62520025050012460 460 28055442549443 475305 330 965 600405 625200250630A14530 530 30065480608470 560380 406

7 965 670350 645200250630B14530 530 30065480608470 560380 406 965 670350 64520030063014530 530 30065486608470 560380 406 965 670350 64525030033512460 460 28055402549443 450254 279 965 600470 625250300425A12500 500 32055402549443 475279 305 965 600495 665250300425B12500 500 32055440549443 475279 305 965 600495 665250300500A14530 530 30065446608470 530330 356 965 670445 645250300500B14530 530 30065446608470 530330 356 965 670445 645#~ 30035069518680 610 37085650740627 720445 445 1170 780600 83035040033514600 560 37565436638500 560315 315 965 600520 72035040042514560 560 35065406608470 560305 305 965 600545 69535040050014600 600 35065516638500 600350 350 965 780445 695# 35040059016700 686 39475480695594 670432 432 965 780600 695# 40045042014670 500 41065480678540 670356 360 965 780600 75540045042514670 500

8 40065516638500 670356 360 965 780600 745# 40045055016686 686 44075570745644 670406 406 965 780600 785# 40045060016700 686 43075570745644 750470 445 965 780600 767# 40045063018700 670 34085667837724 700450 450 1170 780600 820 40050067520840 660 47095612775662 785457 457 1676 780600 1000 40050069520840 660 47095612775662 785457 457 1676 780600 100045050037514700 600 45065556718580 750400 400 965 780600 79545050047514700 670 46165556746580 750428 406 965 780600 820# 45060052516810 700 50075550755654 880495 495 965 1000 700 825# 45060054018990 762 50085575825712 900530 470 1170 1000 700 950# 50050055014700 670 47565480718580 750428 406 965 780600 820# 50060068018838 737 52185590920750 850508 508 1170 1168 940 971 55060044516900 600 56575600850799 900475 475 1170 900700 100060075074022990 990 620 100 693 1100

9 883 965597 597 1350 1000 700 1092 Principal DimensionsMaterialsThe TKL SUPER-TITAN pump issupplied as standard with a cast ironcasing, bronze impeller and stainlesssteel shaft. Other materials to matcha wide range of requirements andspecific liquids can be include austenitic cast iron and zinc free bronze for casing andimpeller; cast iron, austenitic cast iron and stainless steel alloys forimpeller; and a choice of metals forthe wear and sealing rings, sleeves,glands and lantern pumps have Table E flanges except thosewith impeller diameters 590 mm and above which have Table F.

10 Drawing only, not for # Approximate only, subject to in millimetres for cast iron Double volute ~ Frame 18 bearings and frame 16 stuffing + Approximate only, can vary with motor ShaftVertical Shaft dabfqe+c DischargeView indirection ofarrow A A Dischargeh3m1 Suctionh2abh1gfn1 dh2 Suction kh3 Total Head - m200100908070605040302010406080100200400 600800 10002000 L/s200400600800 1000200040006000m3/hVolumetric Flow Rate600500400300200100908070605040 Total Head - ftUS gpm (x 1000)12 4681020 Best Efficiency PointFour shaft elements:Frame No.


Related search queries