Example: dental hygienist

Switching Devices OEM Operating Mechanisms - …

Switching DevicesSafety SwitchesEnclosed Motor DisconnectsBolted Pressure SwitchesOEM Operating MechanismsSwitching Devices CA00801001K September 2013 DevicesIndexContentsDescriptionPageSelec tion Guide .. 2 Product Overview.. 3 Catalogue Configurator.. 4 Options and Accessories .. 5 Technical Data and Specifications .. 7 Standard Terminal Capacities .. 7 Fuse Dimensions .. 8 Short Circuit Ratings.. 10 Flex/Satellite Modifications .. 12 Air Condition Disconnects .. 15 General Duty switches .. 18 Heavy Duty switches .. 22 Heavy Duty Six-Pole switches .. 32 Heavy Duty Double Throw switches .. 35 Enviroline switches .. 41 Heavy Duty Window switches .. 44 Heavy Duty Receptacle switches .. 48 Heavy Duty Voltage Indicator switches .

Switching Devices Safety Switches Enclosed Motor Disconnects Bolted Pressure Switches OEM Operating Mechanisms

Tags:

  Operating, Switches, Mechanisms, Operating mechanisms

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Switching Devices OEM Operating Mechanisms - …

1 Switching DevicesSafety SwitchesEnclosed Motor DisconnectsBolted Pressure SwitchesOEM Operating MechanismsSwitching Devices CA00801001K September 2013 DevicesIndexContentsDescriptionPageSelec tion Guide .. 2 Product Overview.. 3 Catalogue Configurator.. 4 Options and Accessories .. 5 Technical Data and Specifications .. 7 Standard Terminal Capacities .. 7 Fuse Dimensions .. 8 Short Circuit Ratings.. 10 Flex/Satellite Modifications .. 12 Air Condition Disconnects .. 15 General Duty switches .. 18 Heavy Duty switches .. 22 Heavy Duty Six-Pole switches .. 32 Heavy Duty Double Throw switches .. 35 Enviroline switches .. 41 Heavy Duty Window switches .. 44 Heavy Duty Receptacle switches .. 48 Heavy Duty Voltage Indicator switches .

2 52 Hazardous Location switches .. 54 Heavy Duty Quick Connect switches .. 56 Solar switches .. 60 Zone Blasting switches .. 64 Elevator Control switches .. 66 Grounding switches .. 68 Enclosed Motor Disconnects .. 70 Pringle Bolted Pressure switches .. 78 OEM Operating Mechanisms .. 85 CSA Enclosure Designations .. 912 Switching Devices CA00801001K September 2013 DevicesSafety SwitchesSafety Switch Selection GuideNotesaType 12 enclosures (30-1200 amperes) can be field modified to meet Type 3R rainproof requirements when a factory provided drain screw is windows also available with type 12 or 4/4X throw non-fusible 4 pole 30-800A, 6 pole TypeTypeVoltageFuse TypeFuse ClassAmpere RatingNumber of PolescType 1 Type 3 RType 12aType 4 PaintedSteelType 4X Stainless SteelType 4X Non MetallicNEMA 7/9 Hazardous LocationAir Conditioning DisconnectMax.

3 240 VacMax. 240 VacMax. 600 VacFusibleNon-FusibleMoulded Case SwitchNon-FusibleCartridge H 30 and 60606030-802223 YesYesYesYes General DutySingle ThrowMax. 240 VacFusibleNon-FusiblePlugCartridge H 3030-60030-6001 and 22 and 32 and 3 YesYesYesYesYesYes Heavy DutySingle ThrowMax. 600 Vac250 Vdc & 600 VdcFusibleNon-FusibleCartridge HL 30-600800-120030-12002, 3, and 42, 3, and 4 YesUp to 1200 AYesYesUp to 1200 AYesYesabUp to 1200 AYesabUp to 1200 AYesb400-1200 AYesb400-1200 AYesbUp to 1200 AYesbUp to 1200A 6-PoleMotor CircuitbSingle Throw Max. 600 VacFusibleNon-FusibleCartridge H 30-20030-20066 YesYesYesabYesab YesbYesb Double ThrowcMax. 600 VAV250 VdcFusibleNon-FusiblecCartridge HT (240V)T (600V) 30-200400-120030-12002 and 332, 3, 4, 63 YesYesYesYesYesYesYesYesYesab400-600 AYesabUp to 400 AYesb400-600 AYesb400-600 AYesb400-600 AYesbUp to 200A Enclosed Rotary SwitchesMax.

4 600 VacNon-Fusible 30-803 Yesa YesYes Hazardous Location Disconnect SwitchMax. 600 Vac250 VdcFusibleNon-FusibleCartridge J 30-10030-10033 YesYesEnviroline All StainlessbSingle ThrowMax. 600 Vac/DCFusibleNon-FusibleCartridge H 30-40030-4002 and 33 YesbYesb Viewing WindowSingle ThrowMax. 600 Vac/DCFusibleNon-FusibleCartridge H 30-120030-12002, 3, 4, 62, 3, 4, 6 YesaYesaYesYesYesYes Receptacle(Pin & Sleeve)bSingle ThrowMax. 600 Vac/DCFusibleNon-FusibleCartridge H 30-1006033 YesabYesab YesbYesb Quick Connect(Cam & Posi Lok)Single ThrowMax. 600 VacDouble Throw Max. 600 VacFusibleNon-Fusiblew Non-Fusiblew FuseCartridge CartridgeHL HT100-600800100-800 100-200400-8002, 3, and 42, 3, and 42, 3, and 42, 3, and 42, 3, and 42, 3, and 4 YesYesYesYesYesYesYesYesYesYesYesYes SolarSingle ThrowMax.

5 600 VdcFusibleNon-FusibleR 30-60030-6001 (3)1 (3) YesYesYesabYesabYesbYesb Switching Devices CA00801001K September 2013 DevicesSafety SwitchesProduct Overview Used to open or close a circuit Non-fusible safety switches provide a means to manually connect or disconnect the load from the source Fusible safety switches provide a means to manually open and close a circuit and provide overcurrent protection by means of installed fuses Fusible switches certified for use as service entrance equipment (unless noted) Also commonly referred to as a disconnect switch or disconnect Available from 30 1200A All Padlockable Horsepower rated 100% load break rated (unless noted) Non-Fusible switches are 100% continuous duty rated and fusible switches are 80% continuous duty rated per CSA and Certifications File #69743 (Enclosed Rotary) File #162136 Det Norske Veritas ISO 9001:2008 CSA certified Class l, Div, 1 & 2, Groups B, C Class ll, Div 1 & 2, Groups E, G Class lll, Div 1 & 2, Zone 1, llB + H2 for NEMA 7/9.

6 Seismic qualified (UBC and CBC) for Heavy Duty 30-800A ISO 1400 Fuse Clips/ClassNote: Refer to specific switch technical data page for field adaptation to Accept the Following Fuse ClassSafety Switch TypeStandardFuse Class ClipsSupplied with SwitchRJTAC DisconnectH General DutyH30A-600A400-600A400-600 AHeavy DutyH 30-600AL 800-1200A30A-600A240V-100-600A600V-30-60 0A200A-800A1200 AHeavy Duty 6 PoleH30A-200A60A-200A200 ADouble ThrowH 30-200AT 240V-600A-1200AT 600V-400A-800AL 600V-1200A30A-400A240V-200A Only600V-200A-400A240V-600A-1200A600V-40 0A-1200A(Standard)EnvirolineAll Stainless & WindowSame asHeavy DutySame asHeavy DutySame asHeavy DutyReceptacle (Pin & Sleeve)H30A-100A60A-100A SolarR30A - 600A 4 Switching Devices CA00801001K September 2013 DevicesSafety SwitchesCatalogue Number SelectionSafety Switch NotesaAlways verify the number of poles and wires required since catalogue numbers may appear in multiple Pages 12 through 14 for additional Flex Centre table is intended for use in breaking down existing catalogue numbers.

7 It is not intended for building new catalogue = 302 = 603 = 1004 = 2005 = 4006 = 6007 = 8008 = 1200 Fused/Non Fused & NeutralNF= Non Fused no NeutralN= Fused with NeutralBlank= Fused no NeutralEnclosure Type1= Type 1 indoor painted steel3= Type 3R outdoor painted steel4= Type 4/4X watertight, stainless 30 to 200A, painted steel 400A to 1200A12= Type 12 dustight, painted steelPoles/Blades1 = 1 pole2 = 2 poles3 = 3 poles3 = 4 poles6 = 6 polesVoltage Max AC1= 120 Vac2 = 240 Vac6 = 600 VacOptions bW=Window for type 12, 4/4X onlySS=Stainless Steel> 200A316=Grade 316 Stainless SteelCHR=Crouse Hinds Receptacle type 12, 4xAER=Appleton Receptacle (screw door) type 12, 4xARL=Appleton Receptacle (screw cap) type 12, 4xRSR=Russelstoll Receptacle type 12, 4xSwitch TypeHD = Heavy DutyG = General DutyDT = Double Throw4 HD 3 6 3 NF CHRW Fused/Non Fused & NeutralN = Fused with NeutralSN = Fusible Switched NeutralNF = Non Fused no Neutral on GU = Non Fused no NeutralF = Fused no NeutralEnclosure RatingG= Type 1R= Type 3RD= Type 12 or 12/3RW= Type 4X (grade 304 stainless steel)X= Type 7/9 for type DS.

8 4X non metallic for Type 1 for G typeSwitch Type3 GAC = Light Duty for HVac - 3 RGP= Plug FuseG= General Duty 400A & 600A 1ph, 200A & 600A 3phCDG= General Duty 30 to 200A 1ph, 30 to 100A 3phCDH= Heavy Duty EnvirolineDS= Hazardous LocationCDH= Heavy Duty Single Throw Quick Connect (Refer to page 57)CDT= Heavy Duty Double Throw Quick Connect (Refer to page 57)CDH= Solar SwitchesER5= Enclosed RotaryCER5= Enclosed RotaryVoltage Max1 = 120 Vac2 = 240 Vac6 = 600 Vac/dcBlank = 600 Vac for ERS, CERS typeAmpere1= 30A2 = 60A3 = 100A4 = 200A5 = 400A6 = 600A7 = 800A030 = 30A (ER, CER)040 = 40A (CER)060 = 60A (ER, CER)080 = 80A (CER)Options bX=Enviroline (Stainless Operating mechanism in stainless enclosure)W=Window for CDH type only316=Grade 316 Stainless SteelPoles/Blades1 = 1 pole (Solar)2 = 2 poles3 = 3 poles4 = 4 polesCDH 3 6 1 U W K XWDesign TypeK=K switch Heavy Duty designB=General Duty designBlank=G type 200A and above K switch designBlank=ER, CER enclosed rotaryBlank=DS hazardous locationBlank=GP plug fuseSwitching Devices CA00801001K September 2013 DevicesSafety SwitchesOptions and AccessoriesSafety SwitchesSafety switches , continued NotesaFor 6 pole switches with control pole DS16CP contact sales for special one kit for three one kit for each one kit per of switches do not require fuse adapter kits, or kit is included.

9 Fuse blocks or fuse clips are field adaptable. See fuse class adaptation notes under technical data and specifications, for specific switch blade class C fuse must be are not applicable to NEMA 7/9 switches unless indicated NumberNeutral Kits/Ground Kits30A CDGDG030NB60 100A CDGDG100NB200A GD, (Type 3R enclosures), CDGDG200NK30 60A HDDH030NK100A HDDH100NK200A HD (Type 1, 3R enclosures)N200200A HD (Type 4X, 12 enclosures)DH200NK400A GD, HDDS400NK600A GD, HDDS600NK400 600A fusible DT, 800 1200A HDDS800NK30 100A DTDT100NK200A DTDT200NK400A non-fusible DTDT400NK600A non-fusible DTDT600NK800A DTDT800NK1200A DTDT1200 NKGround Lug Kits30 100A CDGDG030GB30 100A HD, DT aDS100GK200A GD, HD, DTDS200GK400 600A GD, 400 1200A HD, 400 800A DTDS468 GKControl Pole Kit (For 2P, 3P switches )a400 600A GD, 30 1200A HD, 30 800A DT, 1 N/0 Aux contactDS16 CPControl Pole Description - Operation - The HD-Series Control Pole provides one normally open contact, late-make, early-break operation (7 lag to main contacts on make ).

10 It mounts in the same position with pre-drilled holes as the neutral block, directly connected to the power pole Operating shaft. Direct connection and visible blades provide more secure electrical interlocking than handle linkage operation of a snap switch type of interlock. This reliability meets the requirements of many specifications for 4-pole switches when the fourth pole is required for secure electrical interlocking. Unit is approved for use with elevating Size Range - #16 to #12 AWG, copper - 10 A continuous, Ac or DcAuxiliary Contact KitsAll switches (except 30 100A GD) 1NO/1 NCDS200EK1 All switches (except 30 100A GD) 2NO/2 NCDS200EK2 NEMA 7/9 switches (30 100A) 1NO/1NC178C265G05 NEMA 7/9 switches (30 100A) 2NO/2NC178C265G06 Enclosed RotarySee page 72DH030 NKDS16 CPDS200EK1Ac Code Rating A600Dc Code Rating N600 Volts AcMakeBreakVolts DcMake & DescriptionCatalogue NumberFuse Puller Kits30A 240V-600V, 60A 240V, pole spacing, SLIDER type (3 per kit)DS32FP30 & 60A 600V, pole spacing STRAP type (3 per kit)DS30FP60A 240V-600V, 2 pole spacing SLIDER type (4 per kit)