Example: air traffic controller

Synchronous rectification boosts efficiency by reducing ...

texas instruments Incorporated Power Management Synchronous rectification boosts efficiency by reducing power loss By Anthony Fagnani Example inputs for this system are a USB port or a lithium- Power Applications Engineer ion (Li-Ion) battery pack with two or three series cells. The DC/DC power supply steps up the voltage for charging Introduction a two-cell Li-Ion battery or the battery of a tablet PC. The Some applications require the highest possible power effi- other application boosts the voltage of a system power rail ciency.

9 Analog Applications Journal Texas Instruments Incorporated 2Q 2013 www.ti.com/aaj High-Performance Analog Products Synchronous rectification boosts efficiency by ...

Tags:

  Efficiency, Texas, Texas instruments, Instruments, Certifications, Synchronous, Boost, Synchronous rectification boosts efficiency by

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Synchronous rectification boosts efficiency by reducing ...

1 texas instruments Incorporated Power Management Synchronous rectification boosts efficiency by reducing power loss By Anthony Fagnani Example inputs for this system are a USB port or a lithium- Power Applications Engineer ion (Li-Ion) battery pack with two or three series cells. The DC/DC power supply steps up the voltage for charging Introduction a two-cell Li-Ion battery or the battery of a tablet PC. The Some applications require the highest possible power effi- other application boosts the voltage of a system power rail ciency.

2 For example, in a harsh environment that requires to a high output voltage that can operate at higher duty a DC/DC power supply to operate in high ambient temper- cycles where the output voltage is much higher than the atures, low-power dissipation is needed to keep the junc- input voltage. An example input is a 12-V power rail. The tion temperature of semiconductor devices within their high output voltage may be needed for power amplifiers, rated range. Other applications may have to meet the industrial PCs, or pump-and-dump energy storage for strict efficiency requirements of ENERGY STAR specifi- higher energy density.

3 Cations or green-mode criteria. Users of battery-operated To evaluate the benefits of Synchronous rectification , applications desire the longest run time possible, and each application is tested with a real circuit to compare reducing the power loss can directly improve run time. efficiency and power loss. The TPS43060/61 Synchronous Today it is well known that using a Synchronous rectifier boost controllers from texas instruments (TI) are used to can reduce power loss and improve thermal capability. demonstrate the Synchronous designs.

4 These current- Designers of buck converters and controllers for step- mode boost controllers integrate the control and gate- down applications are already employing this technique. drive circuitry for both low-side and high-side MOSFETs. Synchronous boost controllers also have been developed TI's TPS40210 current-mode, low-side-switch boost con- to address power efficiency in step-up applications. troller is used for the nonsynchronous designs. Typical application Basic operation Two typical boost applications can be used to demonstrate A typical block diagram for a step-up ( boost ) topology is the difference between Synchronous and nonsynchronous shown in Figure 1.

5 This topology consists of the low-side rectification . The first is a lower-input-voltage application power MOSFET (Q1), the power inductor (L1), and the that may operate at low duty cycles or, in other words, output capacitor (C1). For a Synchronous topology, the when the output voltage is close to the input voltage. high-side MOSFET (Q2) is used for the rectifying switch. Figure 1. Synchronous and nonsynchronous boost circuits Synchronous Rectifier Control DBOOT CBOOT. VCC. Q2. L1. VIN VOUT. IIN D1 IOUT. Q1 C1.

6 Control 9. Analog Applications Journal 2Q 2013 High-Performance Analog Products Power Management texas instruments Incorporated In a nonsynchronous boost topology, a Figure 2. Ideal voltage and current waveforms in a boost circuit power diode (D1) is used. Figure 2 shows the equivalent waveforms for the voltage and current through the switches and inductor. During the ON time of Q1, the Control OFF ON OFF ON. inductor current ramps up, and VOUT is dis- connected from VIN. The output capacitor VOUT. must supply the load during this time.

7 During the OFF time, the inductor current VQ1. ramps down and charges the output capaci- tor through the rectifying switch. The peak current in the rectifier is equal to the peak VOUT. current in the switch. VQ2 or VD1. Selecting the rectifying switch Nonsynchronous controllers use an external power diode as the rectifying switch. Three I L1 IIN. main considerations when selecting the VIN /L1 (VIN VOUT )/L1. power diode are reverse voltage, forward Slopes current, and forward voltage drop. The reverse voltage should be greater than the output voltage, including some margin for I Q1 IIN.

8 Ringing on the switching node. The forward current rating should be at least the same as the peak current in the inductor. The forward voltage should be small to increase IIN. efficiency and reduce power loss. The aver- IQ2 or ID1. age diode current is equal to the average output current. The package of the diode chosen must be capable of handling the power dissipation. Synchronous controllers control another MOSFET for the With a Synchronous rectifier, there are two main sources rectifying switch. If an n-channel MOSFET is used, a volt- of power dissipation conduction and dead-time loss.

9 Age higher than the output voltage must be generated for When the low-side switch turns off, there is a time delay the gate driver. A bootstrap circuit is used to generate this (t DELAY) before the high-side switch turns on. During this voltage. Figure 1 also includes the typical block diagram delay, the body diode (VSD) of the high-side switch con- for a standard bootstrap circuit consisting of the boot strap ducts current. Typically this is referred to as dead time. capacitor (CBOOT) and the bootstrap diode (DBOOT).

10 During When the high-side switch is turned on, there is also con- the ON time of Q1, the bootstrap capacitor is charged to a duction loss due to the RDS(ON) of the MOSFET. Equation 2. regulated voltage (VCC), which typically is regulated by a calculates the duty cycle (D), and Equation 3 estimates low-dropout regulator internal to the controller. When Q1 the losses (PQ2): turns off, the voltage across the capacitor to ground is VOUT VIN. VOUT + VCC, and the required voltage is available to turn on D= (2). VOUT.